B-10-0146
Commercial - New Construction
Closed
LOWES OF PUYALLUP
Other
COMM BUILDING - LOWES
03/12/2010
06/02/2010
10/15/2016
01/23/2012

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Engineering Review Approved 06/01/2010
Planning Review Approved 04/30/2010
Fire Review Approved 04/12/2010

Fees

Paid Fees Amount Paid Owing Date Paid
WA State Building Code Council Fee (Residential) $4.50 $4.50 Paid 06/01/2010
No
Planning Building Permit Fee $120.00 $120.00 Paid 06/01/2010
No
Fire Review Fee (Commercial Building) $265.00 $265.00 Paid 06/01/2010
No
Sewer System Development Charge $26,324.48 $26,324.48 Paid 06/01/2010
No
Planning Landscape Review Fee $300.00 $300.00 Paid 06/01/2010
No
Plumbing Permit Fee $1,789.50 $1,789.50 Paid 06/01/2010
No
Traffic Impact Fee $445,500.00 $445,500.00 Paid 06/01/2010
No
Building Permit Fee $35,516.85 $35,516.85 Paid 06/01/2010
No
Storm System Development Charge $286,880.00 $286,880.00 Paid 06/01/2010
No
Mechanical Permit Fee $503.55 $503.55 Paid 06/01/2010
No
Sanitary Sewer Connection Fee $635.00 $635.00 Paid 06/01/2010
No
Mechanical Plan Review Fee $327.31 $327.31 Paid 03/12/2010
No
Building Plan Review Fee $23,085.95 $23,085.95 Paid 03/12/2010
No
Plumbing Plan Review Fee $1,163.18 $1,163.18 Paid 03/12/2010
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Foundation/Rebar Inspection In Progress 7/15/2010 07/15/2010
Ray Cockerham ((253) 841-5585)
Footing/Setback Inspection In Progress 7/27/2010 07/27/2010
Shannon King ((253) 840-6684)
Plumbing Below Slab Inspection In Progress 07/29/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 7/29/2010 07/29/2010
Shannon King ((253) 840-6684)
Block Wall Rebar Inspection In Progress 8/9/2010 08/09/2010
Monty Johnson ((253) 770-3326)
Block Wall Rebar Inspection In Progress 8/16/2010 08/16/2010
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 8/17/2010 08/17/2010
Monty Johnson ((253) 770-3326)
Block Wall Rebar Inspection In Progress 8/17/2010 08/17/2010
Monty Johnson ((253) 770-3326)
Footing/Setback Inspection In Progress 8/17/2010 08/17/2010
Monty Johnson ((253) 770-3326)
Block Wall Rebar Inspection In Progress 8/19/2010 08/19/2010
Monty Johnson ((253) 770-3326)
Footing/Setback Inspection In Progress 8/24/2010 08/24/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 9/2/2010 09/02/2010
Shannon King ((253) 840-6684)
Block Wall Rebar Inspection In Progress 9/8/2010 09/08/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 9/8/2010 09/08/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 9/14/2010 09/14/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 9/16/2010 09/16/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 9/22/2010 09/22/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 9/28/2010 09/28/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 10/1/2010 10/01/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 10/04/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 10/04/2010
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection In Progress 10/5/2010 10/05/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 10/8/2010 10/08/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 10/12/2010 10/12/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 10/18/2010 10/18/2010
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection In Progress 10/28/2010 10/28/2010
Shannon King ((253) 840-6684)
Frame Inspection In Progress 11/3/2010 11/03/2010
Eric Tague ((253) 864-4192)
Frame Inspection In Progress 11/5/2010 11/05/2010
Eric Tague ((253) 864-4192)
Wallboard / Drywall Inspection In Progress 11/10/2010
Eric Tague ((253) 864-4192)
Footing/Setback Inspection In Progress 11/10/2010 11/10/2010
Eric Tague ((253) 864-4192)
Wallboard / Drywall Inspection In Progress 11/10/2010 11/10/2010
Eric Tague ((253) 864-4192)
Plumbing Rough In Inspection In Progress 11/12/2010 11/12/2010
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 11/16/2010 11/16/2010
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection In Progress 11/17/2010 11/18/2010
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection In Progress 11/30/2010 12/02/2010
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection In Progress 12/1/2010 12/02/2010
Shannon King ((253) 840-6684)
Footing/Setback Inspection In Progress 12/08/2010
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection In Progress 12/9/2010 12/08/2010
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection Approved 12/9/2010 12/08/2010
Shannon King ((253) 840-6684)
Plumbing Below Slab Inspection In Progress 12/9/2010 12/09/2010
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection In Progress 12/10/2010
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection In Progress 12/10/2010 12/10/2010
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection In Progress 12/13/2010 12/13/2010
Eric Tague ((253) 864-4192)
Foundation/Rebar Inspection In Progress 12/14/2010 12/14/2010
Eric Tague ((253) 864-4192)
Plumbing Below Slab Inspection In Progress 12/17/2010 12/17/2010
Shannon King ((253) 840-6684)
Frame Inspection In Progress 12/20/2010 12/20/2010
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection In Progress 12/21/2010 12/21/2010
Shannon King ((253) 840-6684)
Plumbing Below Slab Inspection In Progress 12/22/2010 12/22/2010
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection In Progress 12/28/2010
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 12/28/2010 12/28/2010
Monty Johnson ((253) 770-3326)
Plumbing Below Slab Inspection In Progress 12/29/2010 12/29/2010
rfore
Wallboard / Drywall Inspection In Progress 12/29/2010 12/29/2010
rfore
Gas Test Inspection Approved 01/14/2011
Shannon King ((253) 840-6684)
Ceiling Grid/T-Bar Inspection In Progress 2/4/2011 02/04/2011
Shannon King ((253) 840-6684)
Ceiling Grid/T-Bar Inspection Approved 2/8/2011 02/08/2011
Shannon King ((253) 840-6684)
Fire Final Inspection In Progress 02/22/2011
kenb
Mechanical Final Inspection Approved 03/15/2011
Shannon King ((253) 840-6684)
Fire Final Inspection Approved 03/15/2011
kenb
Building Final Inspection In Progress 3/16/2011 3/16/2011 03/16/2011
Shannon King ((253) 840-6684)
Building Final Inspection Approved 4/4/2011 04/04/2011
Monty Johnson ((253) 770-3326)
Fire Final Inspection Approved 4/1/2011 4/4/2011 04/04/2011
rfore
Final TCO Inspection Approved 4/18/2016 04/18/2016
Ray Cockerham ((253) 841-5585)
Foundation/Rebar Inspection VOID 12/09/2021
rfore
Footing/Setback Inspection VOID 12/09/2021
rfore
Foundation/Rebar Inspection VOID 7/21/2010 12/09/2021
Ray Cockerham ((253) 841-5585)
Footing/Setback Inspection VOID 7/21/2010 12/09/2021
Shannon King ((253) 840-6684)
Plumbing Rough In Inspection VOID 7/29/2010 12/09/2021
Shannon King ((253) 840-6684)
Frame Inspection VOID 10/29/2010 12/09/2021
Shannon King ((253) 840-6684)
Frame Inspection VOID 11/1/2010 12/09/2021
Eric Tague ((253) 864-4192)
Plumbing Below Slab Inspection VOID 12/7/2010 12/09/2021
Shannon King ((253) 840-6684)
Plumbing Rough In Inspection VOID 1/14/2011 12/09/2021
Shannon King ((253) 840-6684)
Ceiling Grid/T-Bar Inspection VOID 2/3/2011 12/09/2021
Shannon King ((253) 840-6684)
Plumbing Final Inspection VOID 2/3/2011 12/09/2021
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection VOID 2/7/2011 12/09/2021
Shannon King ((253) 840-6684)
Fire Final Inspection VOID 2/22/2011 2/22/2011 12/09/2021
Shannon King ((253) 840-6684)
Mechanical Final Inspection VOID 3/2/2011 12/09/2021
Shannon King ((253) 840-6684)
Fire Final Inspection VOID 3/2/2011 3/2/2011 12/09/2021
rfore
Fire Final Inspection VOID 3/14/2011 3/14/2011 12/09/2021
kenb
Frame Inspection VOID 3/15/2011 12/09/2021
Shannon King ((253) 840-6684)
Building Final Inspection VOID 3/15/2011 12/09/2021
Shannon King ((253) 840-6684)

Conditions

Condition Status Department Category Expiration Date Due Date
General Permit Conditions Resolved Building Division Standard Conditions
: Final approval by the Building Official is required prior to occupancy. WORK SHALL NOT PROCEED UNTIL THE INSPECTOR HAS APPROVED THE STAGES OF CONSTRUCTION SURFACE STORM WATER SHALL BE DIVERTED FROM THE BUILDING SITE AND SHALL NOT DRAIN ONTO ADJACENT PROPERTIES. Rain drains shall connect to the storm sewer or discharge at the street. I hereby acknowledge that I have read this Permit/Application, that the information given is correct: that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Once work has started (passed a required inspection) one inspection per year must be completed to keep active or it will formally expire and become null and void. BY LEAVING THE CONTRACTOR INFORMATION SECTION BLANK, I HEREBY CERTIFY FURTHER THAT CONTRACTORS (GENERAL OR SUBCONTRACTORS) WILL NOT BE HIRED TO PERFORM ANY WORK IN ASSOCIATION WITH THIS PERMIT. I ALSO CERTIFY THAT IF I DO CHOOSE TO HIRE A CONTRACTOR (GENERAL OR SUBCONTRACTOR) I WILL ONLY HIRE THOSE CONTRACTORS THAT ARE LICENSED BY THE STATE OF WASHINGTON.
Fire Review Conditions Resolved Standard Conditions
: 1. INSTALL ADDRESS NUMBERS PER THE FOLLOWING DISTANCES:0-50FOOT SETBACK FROM STREET NUMBERS SHALL BE 6 INCHES IN HEIGHT; 51-100 FEET 12 INCHES IN HEIGHT. ALL NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDITIONAL NUMBERS MAY BE NEEDED AT DRIVEWAY ENTRANCE IF BUILDING NUMBERS ARE NOT VISIBLE FROM THE STREET. REAR DOORS OF SUITES OR UNITS SHALL ALSO BE LABELED WITH MINIMUM 4 INCH NUMBERS. 2. FIRE HYDRANTS REQUIRED FOR CONSTRUCTION AND FIRE DEPARTMENT ACCESS SHALL BE INSTALLED AND APPROVED BY THE FIRE CODE OFFICIAL PRIOR TO THE STORAGE OR INSTALLATION OF ANY COMBUSTIBLE FRAMING MATERIAL. ACCESS ROADWAY SURFACES SHALL BE DESIGNED TO CITY STANDARDS AND BE DESIGNED TO MAINTAIN THE IMPOSED LOADS OF A 80,000 POUND FIRE APPARATUS. ASPHALT TREATED BASE, ASPHALT OR CONCRETE PAVEMENT CAN BE USED TO PROVIDE THE REQUIRED ALL-WEATHER DRIVING SURFACE. 3. ANY REQUIRED FIRE LANE MARKINGS SHALL BE INSTALLED PRIOR TO FINAL INSPECTION AND PER CITY ORDINANCE. 4. KNOX BOXES, WHEN REQUIRED, SHALL BE INSTALLED USUALLY TO THE RIGHT OF THE MAIN FRONT DOOR AND NO HIGHER THAN 6 FEET OFF OF THE GROUND. ONLY HINGED KNOX BOXES SHALL BE USED. KNOX BOXES AND KEY SWITCHES CAN BE ORDERED ONLINE AT THE "KNOX COMPANY" 5. FIRE EXTINGUISHERS WILL BE REQUIRED PER CHAPTER 9 OF THE INTERNATIONAL FIRE CODE. GENERALLY, 1 FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A 10BC SHALL BE INSTALLED PER EVERY 3,000 SQUARE FEET OF FLOOR AREA. THE LOCATION OF THE FIRE EXTINGUISHERS SHALL BE NEAR THE EXIT DOORS AND TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. ADDITIONAL SIGNAGE MAY BE NECESSARY TO INDICATE THE FIRE EXTINGUISHER LOCATION. 6. FIRE ALARM SYSTEM SHALL BE DESIGNED TO TOTAL COVERAGE AND A UL CERTIFICATE IS REQUIRED PER CITY ORDINANCE. FIRE SPRINKLER AND FIRE ALARM PERMITS ARE REQUIRED. FIRE MARSHAL INSPECTION CODES: 5101 FIRE ACCESS 5102 FIRE HYDRANTS 5103 ADDRESS NUMBERS 5104 FIRE LANE MARKINGS 5106 FIRE OR SMOKE DAMPER 9200 FIRE FINAL BUILDING PERMIT
Building Permit Standard Conditions Resolved Building Division Standard Conditions
: PERMIT CONDITIONS: 1. THE APPLICANT IS RESPONSIBLE TO CALL THE INSPECTION LINE AT 253-445-4795 OR 253-445-5092 TO SCHEDULE INSPECTIONS. UTILITY INSPECTIONS ARE REQUIRED PRIOR TO BACKFILLING. 2. For Engineering questions arising in the field, please contact the Engineering Inspector at 253-435-1707. 3. No work shall be done in or on the public right of way without a licensed and bonded contractor first obtaining a right of way permit. BUILDING CONDITIONS Exit path illumination. At final inspection the Building Division will require the contractor to provide a light meter to test (at night or early morning) for the lumens at floor level. IBC 1006. Plumbing - A system is labeled Non-Potable in the garden center. It A RPBA will be required on this line to provide an appropriate level of cross connection protection Lines will be required to be labeled at 20 feet on center, each side of walls and a dispensing points. Coffee dispenser requires cross connection protection. Contractor Responsibility - Please provide a written statement as described in 1706 of the IBC prior to commencing construciton.