CITY OF PUYALLUP PERMITTING PORTAL

Permit Application Status

B-11-0536


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

B-11-0536
Commercial - New Construction
Closed
BCC PUYALLUP LLC
Other
CONST SHELL/CORE ~ GROUP HEALTH CLINIC BLDG/MECH/PLUMB
09/06/2011
12/07/2011
03/04/2012
10/04/2012

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Legacy Activity (see Comments) Approved 11/30/2011
Engineering Review Approved 11/29/2011
Fire Review Approved 11/01/2011
Building Review Approved 09/21/2011

Fees

Paid Fees Amount Paid Owing Date Paid
Building Division Fee (Hourly) $130.00 $130.00 Paid 12/16/2011
No
Legacy Fee $200.00 $200.00 Paid 12/07/2011
No
Planning Building Permit Fee $120.00 $120.00 Paid 12/07/2011
No
Legacy Fee $200.00 $200.00 Paid 12/07/2011
No
WA State Building Code Council Fee (Residential) $4.50 $4.50 Paid 12/07/2011
No
Plumbing Plan Review Fee $93.60 $93.60 Paid 12/07/2011
No
Fire Review Fee (Commercial Building) $265.00 $265.00 Paid 12/07/2011
No
Plumbing Permit Fee $144.00 $144.00 Paid 12/07/2011
No
Mechanical Plan Review Fee $180.18 $180.18 Paid 12/07/2011
No
Mechanical Permit Fee $277.20 $277.20 Paid 12/07/2011
No
Planning Landscape Review Fee $300.00 $300.00 Paid 12/07/2011
No
Sanitary Sewer Connection Fee $635.00 $635.00 Paid 12/07/2011
No
Water System Development Charge $3,130.00 $3,130.00 Paid 12/07/2011
No
Sewer System Development Charge $4,520.00 $4,520.00 Paid 12/07/2011
No
Legacy Fee $76,300.00 $76,300.00 Paid 12/07/2011
No
Storm System Development Charge $103,840.00 $103,840.00 Paid 12/07/2011
No
Building Permit Fee $50,343.15 $50,343.15 Paid 09/06/2011
No
Building Plan Review Fee $32,723.05 $32,723.05 Paid 09/06/2011
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Footing/Setback Inspection In Progress 12/9/2011 12/09/2011
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 12/14/2011 12/14/2011
Monty Johnson ((253) 770-3326)
Footing/Setback Inspection In Progress 12/15/2011
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 12/16/2011 12/16/2011
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 12/20/2011 12/20/2011
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 12/22/2011 12/22/2011
Monty Johnson ((253) 770-3326)
Shear Wall Inspection In Progress 12/28/2011 12/28/2011
jonw
Foundation/Rebar Inspection In Progress 12/29/2011 12/29/2011
Monty Johnson ((253) 770-3326)
Plumbing Below Slab Inspection In Progress 01/05/2012
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection In Progress 1/5/2012 01/06/2012
Shannon King ((253) 840-6684)
Plumbing Below Slab Inspection In Progress 01/11/2012
Shannon King ((253) 840-6684)
Slab/Insulation Inspection In Progress 1/13/2012 01/13/2012
Shannon King ((253) 840-6684)
Plumbing Below Slab Inspection In Progress 1/13/2012 01/13/2012
Shannon King ((253) 840-6684)
Slab/Insulation Inspection Approved 1/23/2012 01/23/2012
Monty Johnson ((253) 770-3326)
Plumbing Below Slab Inspection In Progress 1/26/2012 01/26/2012
Monty Johnson ((253) 770-3326)
Slab/Insulation Inspection In Progress 1/26/2012 01/26/2012
Monty Johnson ((253) 770-3326)
Slab/Insulation Inspection Approved 2/2/2012 02/02/2012
Monty Johnson ((253) 770-3326)
Slab/Insulation Inspection In Progress 2/6/2012 02/06/2012
Monty Johnson ((253) 770-3326)
Tilt Up Panel Inspection Approved 2/6/2012 02/06/2012
Monty Johnson ((253) 770-3326)
Tilt Up Panel Inspection In Progress 2/7/2012 02/07/2012
Monty Johnson ((253) 770-3326)
Plumbing Below Slab Inspection In Progress 2/8/2012 02/08/2012
Monty Johnson ((253) 770-3326)
Tilt Up Panel Inspection In Progress 2/9/2012 02/09/2012
Monty Johnson ((253) 770-3326)
Tilt Up Panel Inspection In Progress 2/13/2012 02/13/2012
Monty Johnson ((253) 770-3326)
Slab/Insulation Inspection Approved 3/5/2012 03/05/2012
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 3/15/2012 03/15/2012
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 3/15/2012 03/15/2012
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 3/19/2012 03/19/2012
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 3/21/2012 03/21/2012
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection In Progress 3/22/2012 03/22/2012
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 3/26/2012 03/26/2012
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 3/30/2012 03/30/2012
Monty Johnson ((253) 770-3326)
Energy (Insulation) Inspection In Progress 04/03/2012
Monty Johnson ((253) 770-3326)
Energy (Insulation) Inspection In Progress 4/4/2012 04/04/2012
Monty Johnson ((253) 770-3326)
Energy (Insulation) Inspection In Progress 4/5/2012 04/05/2012
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 4/10/2012 04/10/2012
Monty Johnson ((253) 770-3326)
Wallboard / Drywall Inspection In Progress 4/10/2012 04/10/2012
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 04/16/2012
Monty Johnson ((253) 770-3326)
Energy (Insulation) Inspection In Progress 4/16/2012 04/16/2012
Monty Johnson ((253) 770-3326)
Wallboard / Drywall Inspection In Progress 4/16/2012 04/16/2012
Monty Johnson ((253) 770-3326)
Wallboard / Drywall Inspection In Progress 4/18/2012 04/18/2012
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 05/18/2012
Shannon King ((253) 840-6684)
Energy (Insulation) Inspection In Progress 5/18/2012 05/18/2012
Shannon King ((253) 840-6684)
Block Wall Rebar Inspection In Progress 5/18/2012 05/18/2012
Shannon King ((253) 840-6684)
Energy (Insulation) Inspection In Progress 5/21/2012 05/21/2012
Monty Johnson ((253) 770-3326)
Frame Inspection In Progress 5/21/2012 05/21/2012
Monty Johnson ((253) 770-3326)
Energy (Insulation) Inspection In Progress 6/4/2012 06/04/2012
Monty Johnson ((253) 770-3326)
Plumbing Final Inspection Approved 9/5/2012 09/05/2012
Eric Tague ((253) 864-4192)
Frame Inspection In Progress 9/11/2012 09/11/2012
Monty Johnson ((253) 770-3326)
Engineering Final Inspection Approved 09/18/2012
charris
Mechanical Final Inspection Approved 9/18/2012 09/18/2012
Monty Johnson ((253) 770-3326)
Engineering Final Inspection Approved 9/18/2012 09/18/2012
Monty Johnson ((253) 770-3326)
Fire Final Inspection In Progress 9/19/2012 09/19/2012
rfore
Fire Final Inspection Approved 10/3/2012 10/03/2012
rfore
Building Final Inspection Approved 10/4/2012 10/04/2012
Monty Johnson ((253) 770-3326)
Comment Building Div Inspection VOID 12/8/2011 12/09/2021
Monty Johnson ((253) 770-3326)
Comment Building Div Inspection VOID 12/15/2011 12/09/2021
Monty Johnson ((253) 770-3326)
Plumbing Rough In Inspection VOID 1/4/2012 12/09/2021
Shannon King ((253) 840-6684)
Comment Building Div Inspection VOID 1/5/2012 12/09/2021
Shannon King ((253) 840-6684)
Plumbing Rough In Inspection VOID 1/11/2012 12/09/2021
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection VOID 3/7/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Comment Building Div Inspection VOID 3/15/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Frame Inspection VOID 3/22/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Comment Building Div Inspection VOID 3/30/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Slab/Insulation Inspection VOID 4/3/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Comment Building Div Inspection VOID 4/4/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Frame Inspection VOID 4/4/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Wallboard / Drywall Inspection VOID 4/23/2012 12/09/2021
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection VOID 4/26/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Block Wall Rebar Inspection VOID 5/2/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Frame Inspection VOID 5/2/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Block Wall Rebar Inspection VOID 5/3/2012 12/09/2021
Shannon King ((253) 840-6684)
Mechanical Final Inspection VOID 8/30/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Plumbing Final Inspection VOID 8/30/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Plumbing Final Inspection VOID 9/4/2012 12/09/2021
Eric Tague ((253) 864-4192)
Mechanical Final Inspection VOID 9/10/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Building Final Inspection VOID 9/18/2012 12/09/2021
Monty Johnson ((253) 770-3326)
Building Final Inspection VOID 9/19/2012 12/09/2021
Monty Johnson ((253) 770-3326)

Conditions

Condition Status Department Category Expiration Date Due Date
General Permit Conditions Resolved Building Division Standard Conditions
: * Final approval by the Building Official is required prior to occupancy. *Work shall not proceed until the inspector has approved the stages of construction. *Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties. * I hereby acknowledge that I have read this Permit/Application, that the information given is correct: that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Once work has started (passed a required inspection) one inspection per year must be completed to keep active or it will formally expire and become null and void. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the state of Washington.
Fire Review Conditions Resolved Standard Conditions
: 1. INSTALL ADDRESS NUMBERS PER THE FOLLOWING DISTANCES:0-50FOOT SETBACK FROM STREET NUMBERS SHALL BE 6 INCHES IN HEIGHT; 51-100 FEET 12 INCHES IN HEIGHT. ALL NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDITIONAL NUMBERS MAY BE NEEDED AT DRIVEWAY ENTRANCE IF BUILDING NUMBERS ARE NOT VISIBLE FROM THE STREET. 2. FIRE HYDRANTS REQUIRED FOR CONSTRUCTION AND FIRE DEPARTMENT ACCESS SHALL BE INSTALLED AND APPROVED BY THE FIRE CODE OFFICIAL PRIOR TO THE STORAGE OR INSTALLATION OF ANY COMBUSTIBLE FRAMING MATERIAL. ACCESS ROADWAY SURFACES SHALL BE DESIGNED TO CITY STANDARDS AND BE DESIGNED TO MAINTAIN THE IMPOSED LOADS OF A 75,000 POUND FIRE APPARATUS. ASPHALT TREATED BASE, ASPHALT OR CONCRETE PAVEMENT CAN BE USED TO PROVIDE THE REQUIRED ALL-WEATHER DRIVING SURFACE. 3. ANY REQUIRED FIRE LANE MARKINGS SHALL BE INSTALLED PRIOR TO FINAL INSPECTION AND PER CITY ORDINANCE. FIRE LANE MARKINGS WILL BE INDICATED ON CIVIL PLANS. 4. KNOX BOXES (key boxes) WILL BE REQUIRED. THE LOCATION AND TYPE WILL BE DETERMINED BY CENTRAL PIERCE FIRE AND RESCUE DURING THE CONSTRUCTION PHASE. 5. FIRE EXTINGUISHERS WILL BE REQUIRED PER CHAPTER 9 OF THE INTERNATIONAL FIRE CODE. GENERALLY, 1 FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A 10BC SHALL BE INSTALLED PER EVERY 3,000 SQUARE FEET OF FLOOR AREA. THE LOCATION OF THE FIRE EXTINGUISHERS SHALL BE NEAR THE EXIT DOORS AND TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. ADDITIONAL SIGNAGE MAY BE NECESSARY TO INDICATE THE FIRE EXTINGUISHER LOCATION. 5. FIRE SPRINKLER PLANS AND FIRE ALARM PERMITS ARE REQUIRED. 6. STANDPIPE SYSTEM IS REQUIRED 7. EMERGENCY LIGHTING TEST WILL BE REQUIRED 8. GENERATORS CONNECTED TO ANY LIFE SAFETY SYSTEM WILL REQUIRE A PERMIT. FIRE MARSHAL INSPECTION CODES: 5101 FIRE ACCESS 5102 FIRE HYDRANTS 5103 ADDRESS NUMBERS 5104 FIRE LANE MARKINGS 5106 FIRE OR SMOKE DAMPER 9200 FIRE FINAL BUILDING PERMIT

Related Permit & Planning Applications

There are no related items for this permit application.

Documents & Images

No documents are currently available for viewing.


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.