Summary

B-18-0311
Mechanical - COMMERCIAL ONLY
Expired
BCC PUYALLUP LLC
Other
(2) 575 ton variable speed York centrifugal chillers, (2) cooling otwers with SS sump, sump heater service ladder and guardrails. (2) base mounted end suction centrifugal pumps with VFD for chillers (2) base mounted end suction centrifugal pumps with VFD for cooling towers (1) Alfa Laval flat plate HX for cooling tower with VFD to accommodate economizer operation.
04/17/2018
08/06/2018
11/19/2019

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Building Review VOID 12/09/2021
Building Review Approved 08/02/2018

Fees

Paid Fees Amount Paid Owing Date Paid
Legacy Fee $130.00 $130.00 Paid 08/03/2018
No
Building Division Fee (Hourly) $130.00 $130.00 Paid 05/25/2018
No
Mechanical Plan Review Fee $570.34 $570.34 Paid 04/18/2018
No
Mechanical Permit Fee $945.64 $945.64 Paid 04/18/2018
No
Mechanical Plan Review Fee $44.33 $44.33 Paid 04/17/2018
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Comment Building Div Inspection VOID 12/09/2021
Legacy user
Mechanical Rough In Inspection VOID 12/09/2021
Legacy user
Comment Building Div Inspection VOID 12/09/2021
Ray Cockerham ((253) 841-5585)
Mechanical Final Inspection VOID 12/09/2021
Legacy user
Hydronic Piping Inspection VOID 12/09/2021
Legacy user
Foundation/Rebar Inspection VOID 12/09/2021
Legacy user
Hydronic Piping Inspection VOID 8/7/2018 12/09/2021
Monty Johnson ((253) 770-3326)
Comment Building Div Inspection VOID 12/5/2018 12/09/2021
Gary Webster ((253) 841-5590)
Mechanical Rough In Inspection VOID 5/21/2019 12/09/2021
Gary Webster ((253) 841-5590)
Mechanical Final Inspection VOID 5/21/2019 12/09/2021
Gary Webster ((253) 841-5590)
Hydronic Piping Inspection VOID 5/21/2019 12/09/2021
Gary Webster ((253) 841-5590)

Conditions

Condition Status Department Category Expiration Date Due Date
General Permit Conditions Resolved Building Division Standard Conditions
: * Final approval by the Building Official is required prior to use or occupancy. * Work shall not proceed until the inspector has approved the stages of construction. * Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties. * I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. * TO SCHEDULE INSPECTIONS, CHECK PERMIT STATUS OR TO MAKE PAYMENTS ON THE CITY WEB SITE VISIT https://secure.cityofpuyallup.org/
Roof Top Screening Standard Conditions Resolved Building Division Standard Conditions
: PERMIT CONDITIONS: ALL EXTERIOR MECHANICAL EQUPMENT SHALL BE SCREENED FROM VIEW OF SURROUNDING PUBLIC STREETS AND RESIDENTIAL PROPERTIES. ***SUBJECT TO FINAL INSPECTION*** Call the inspection line at 1-877-232-6456 to schedule inspections. Use the Permit ID located at the top right of the permit when prompted for Permit ID. The City attempts to honor the AM/PM requested inspection, but cannot guarantee that service. Please call Monty - East of Meridian at 253-770-3326 or Shannon - West of Meridian at 253-840-6684 before 8:30 AM on the day of inspection to verify time. Building comments; Final letter from the Mechanical Engineer of record is required, submit to field inspector at or before final inspector request. Contractor to verify guards and service ladder(access) is code compliant.