Permit Application Status

B-19-0402


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

B-19-0402
Commercial - Tenant Improvement/Remodel
Closed
GOOD SAMARITIAN HOSPITAL
Alteration/Remodel
TI ~ GSH RENOVATE 1ST FL PATIENT WING FOREST PAVILION PATIENT SLEEP/CARE BLDG/MECH/PLUMB
05/06/2019
11/26/2019
12/12/2022
06/15/2022

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Building Review Approved 11/08/2019
Engineering Review Approved 08/08/2019
Building Review Incomplete 07/30/2019
Planning Review Approved 06/27/2019
Fire Review Approved 06/12/2019

Fees

Paid Fees Amount Paid Owing Date Paid
WA State Building Code Council Fee (Residential) $25.00 $25.00 Paid 11/26/2019
No
Building Plan Review Fee $1,828.94 $1,828.94 Paid 11/26/2019
No
Legacy Fee $130.00 $130.00 Paid 11/26/2019
No
Fire Review Fee (Commercial Building) $265.00 $265.00 Paid 11/26/2019
No
Planning Landscape Review Fee $300.00 $300.00 Paid 11/26/2019
No
Mechanical Plan Review Fee $117.65 $117.65 Paid 11/26/2019
No
Building Division Fee (Hourly) $130.00 $130.00 Paid 11/26/2019
No
Sewer System Development Charge $3,967.26 $3,967.26 Paid 11/26/2019
No
Plumbing Permit Fee $365.00 $365.00 Paid 11/26/2019
No
Building Permit Fee $2,813.75 $2,813.75 Paid 11/26/2019
No
Legacy Fee $130.00 $130.00 Paid 11/26/2019
No
Planning Building Permit Fee $120.00 $120.00 Paid 11/26/2019
No
Water System Development Charge $2,870.67 $2,870.67 Paid 11/26/2019
No
Mechanical Permit Fee $181.00 $181.00 Paid 11/26/2019
No
Plumbing Plan Review Fee $237.25 $237.25 Paid 11/26/2019
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Comment Building Div Inspection Comments 1/21/2020 01/21/2020
Monty Johnson ((253) 770-3326)
Mechanical Rough In Inspection In Progress 3/6/2020 03/06/2020
Monty Johnson ((253) 770-3326)
Comment Building Div Inspection Comments 6/24/2021 06/24/2021
Shannon King ((253) 840-6684)
Frame Inspection In Progress 8/26/2021 08/26/2021
Gary Webster ((253) 841-5590)
Energy (Insulation) Inspection In Progress 8/27/2021 08/27/2021
Gary Webster ((253) 841-5590)
Wallboard / Drywall Inspection In Progress 9/1/2021 09/01/2021
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection In Progress 9/7/2021 09/07/2021
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection In Progress 9/9/2021 09/09/2021
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection In Progress 9/30/2021 09/30/2021
Gary Webster ((253) 841-5590)
Plumbing Rough In Inspection Failed 9/30/2021 09/30/2021
Gary Webster ((253) 841-5590)
Plumbing Rough In Inspection In Progress 10/4/2021 10/04/2021
Shannon King ((253) 840-6684)
Comment Building Div Inspection Comments 12/2/2021 12/02/2021
Shannon King ((253) 840-6684)
Mechanical Rough In Inspection Partial Pass 12/15/2021 12/15/2021 12/15/2021
Shannon King ((253) 840-6684)
Other/Miscellaneous
Outstanding
12/15/2021
1 ; run test approved at sink tie-in in room 172.

Comment Building Div Inspection Partial Pass 12/16/2021 12/16/2021 12/16/2021
Shannon King ((253) 840-6684)
Other/Miscellaneous
Outstanding
12/16/2021
1 ; inspection of med. gas valve box relocation at room 170. 2 ; test approved at - 150,150,160 ( called for med. gas inspection only)

Frame Inspection Partial Pass 1/24/2022 1/24/2022 01/24/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
01/24/2022
1 ; complete nailplates at electrical as discussed with contractor. 2 ; complete fireproofing at steel columns and cross beams. 3 ; toilet to be 16''-18'' from wall to center line of toilet in room 183A. 4 ; inspection of rooms - (164,166,168,170,172,174,178,180,182,184,186;188,187,185,183,181) ok to cover

Mechanical Rough In Inspection Partial Pass 1/24/2022 1/24/2022 01/24/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
01/24/2022
1 ; ok to cover hardlids at grid line - (a-b.3,3-9) (rooms - 181,183,185,187 only)

Frame Inspection Partial Pass 1/27/2022 1/27/2022 01/27/2022
Gary Webster ((253) 841-5590)
Other/Miscellaneous
Resolved
01/27/2022
1 ; complete nailplates at electrical as discussed with contractor. 2 ; complete fireproofing at steel columns and cross beams. 3 ; toilet to be 16''-18'' from wall to center line of toilet in room 183A. 4 ; inspection of rooms - (164,166,168,170,172,174,178,180,182,184,186;188,187,185,183,181) ok to cover

Other/Miscellaneous
Carried Forward
01/27/2022
wall cover ok minus rm #'s 160 & 162

Wallboard / Drywall Inspection Partial Pass 1/31/2022 1/31/2022 01/31/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
01/31/2022
1 ; approved drywall nailing in rooms - 164,166,168,170,172,174,1178,180,182,184,186,188,187,185,183,181, only

Frame Inspection Partial Pass 2/1/2022 2/1/2022 02/01/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
02/01/2022
wall cover ok minus room # - 160 (approved room 162)

Other/Miscellaneous
Carried Forward
02/01/2022
approved room 162

Comment Building Div Inspection Partial Pass 2/1/2022 2/1/2022 02/01/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
02/01/2022
1 ; inspection of 1st layer in room - 111, 162 complete

Wallboard / Drywall Inspection Partial Pass 2/4/2022 2/4/2022 02/04/2022
Gary Webster ((253) 841-5590)
Other/Miscellaneous
Carried Forward
02/04/2022
1 ; approved drywall nailing in rooms - 164,166,168,170,172,174,1178,180,182,184,186,188,187,185,183,181, only

Other/Miscellaneous
Carried Forward
02/04/2022
gwb approved in rms 162 & 101a-111

Frame Inspection Partial Pass 2/4/2022 2/4/2022 02/04/2022
Gary Webster ((253) 841-5590)
Other/Miscellaneous
Carried Forward
02/04/2022
wall cover ok minus room # - 160 (approved room 162)

Other/Miscellaneous
Carried Forward
02/04/2022
approved room 162

Other/Miscellaneous
Carried Forward
02/04/2022
rm #160 - ok

Wallboard / Drywall Inspection Partial Pass 2/8/2022 2/8/2022 02/08/2022
Gary Webster ((253) 841-5590)
Other/Miscellaneous
Carried Forward
02/08/2022
1 ; approved drywall nailing in rooms - 164,166,168,170,172,174,1178,180,182,184,186,188,187,185,183,181, only

Other/Miscellaneous
Carried Forward
02/08/2022
gwb approved in rms 162 & 101a-111

Other/Miscellaneous
Carried Forward
02/08/2022
rms # 160 & 174 - ok corridor - ok

Frame Inspection Partial Pass 2/28/2022 2/28/2022 02/28/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
02/28/2022
wall cover ok minus room # - 160 (approved room 162)

Other/Miscellaneous
Carried Forward
02/28/2022
approved room 162

Other/Miscellaneous
Carried Forward
02/28/2022
rm #160 - ok

Other/Miscellaneous
Carried Forward
02/28/2022
1 ; approved rated wall framing in rooms 173,175,177, east walls.

Wallboard / Drywall Inspection Partial Pass 3/3/2022 3/3/2022 03/03/2022
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection Partial Pass 3/4/2022 3/4/2022 03/04/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Resolved
03/04/2022
1 ; approved drywall nailing in rooms - 164,166,168,170,172,174,1178,180,182,184,186,188,187,185,183,181, only

Other/Miscellaneous
Resolved
03/04/2022
gwb approved in rms 162 & 101a-111 1 ; approved all drywall except room 171

Frame Inspection Partial Pass 3/7/2022 3/7/2022 03/07/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
03/07/2022
wall cover ok minus room # - 160 (approved room 162)

Other/Miscellaneous
Carried Forward
03/07/2022
approved room 162

Other/Miscellaneous
Carried Forward
03/07/2022
rm #160 - ok

Other/Miscellaneous
Resolved
03/07/2022
1 ; approved rated wall framing in rooms 173,175,177, east walls.

Other/Miscellaneous
Carried Forward
03/07/2022
1 ; approved furred wall framing in room 171A and soffit in room 170

Wallboard / Drywall Inspection Partial Pass 3/7/2022 3/7/2022 03/07/2022
Shannon King ((253) 840-6684)
Ceiling Grid/T-Bar Inspection Partial Pass 3/25/2022 3/25/2022 03/25/2022
Gary Webster ((253) 841-5590)
Other/Miscellaneous
Carried Forward
03/25/2022
1 provide electrical final 2 seal penetrations above grid in rm #171A ok to drop tiles after elec approval, provide access to reinspect area in rm #171A

Building Final Inspection Not Ready 6/8/2022 6/8/2022 06/08/2022
Monty Johnson ((253) 770-3326)
Other/Miscellaneous
Carried Forward
06/08/2022
1:cancelled by ryan

Mechanical Final Inspection Not Ready 6/8/2022 6/8/2022 06/08/2022
Monty Johnson ((253) 770-3326)
Other/Miscellaneous
Carried Forward
06/08/2022
1:cancelled by ryan

Plumbing Final Inspection Not Ready 6/8/2022 6/8/2022 06/08/2022
Monty Johnson ((253) 770-3326)
Other/Miscellaneous
Carried Forward
06/08/2022
cancelled by ryan

Building Final Inspection Failed 6/9/2022 6/9/2022 06/09/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
06/09/2022
1 ; provide D.O.H. approval letter. 2 ; complete vertical grab bar in restroom as discussed with contractor. 3 ; provide special inspection final letter at time of final. 4 ; complete all plumbing boots at required sinks. 5 ; complete install of hammer arrestors at clothes washing machine and icemaker. 6 ; provide install instructions for ice machine showing 1'' air gap or provide backflow protection as per code. 7 ; provide backflow certifications at time of final.

Plumbing Final Inspection Failed 6/9/2022 6/9/2022 06/09/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
06/09/2022
1 ; provide D.O.H. approval letter. 2 ; complete all plumbing boots at required sinks. 3 ; complete install of hammer arrestors at clothes washing machine and icemaker. 4 ; provide install instructions for ice machine showing 1'' air gap or provide backflow protection as per code. 5 ; provide backflow certifications at time of final.

Building Final Inspection Failed 6/13/2022 6/13/2022 06/13/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Resolved
06/13/2022
1 ; provide D.O.H. approval letter. 2 ; complete vertical grab bar in restroom as discussed with contractor. 3 ; provide special inspection final letter at time of final. 4 ; complete all plumbing boots at required sinks. 5 ; complete install of hammer arrestors at clothes washing machine and icemaker. 6 ; provide install instructions for ice machine showing 1'' air gap or provide backflow protection as per code. 7 ; provide backflow certifications at time of final.

Other/Miscellaneous
Carried Forward
06/13/2022
1 ; provide special inspection final letter prior to building final inspection approval.

Building Final Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Outstanding
06/13/2022
1 ; provide special inspection final letter prior to building final inspection approval.

Wallboard / Drywall Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Ceiling Grid/T-Bar Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Frame Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Outstanding
03/07/2022
wall cover ok minus room # - 160 (approved room 162)

Other/Miscellaneous
Outstanding
03/07/2022
approved room 162

Other/Miscellaneous
Outstanding
03/07/2022
rm #160 - ok

Other/Miscellaneous
Outstanding
03/07/2022
1 ; approved furred wall framing in room 171A and soffit in room 170

Comment Building Div Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Plumbing Rough In Inspection Partial Pass 12/2/2021 06/15/2022
Shannon King ((253) 840-6684)
Plumbing Rough In Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Plumbing Rough In Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Planning Final Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Footing/Setback Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Comment Building Div Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Combination Frame And Rough In Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Shear Wall Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Carbon Monoxide Detectors Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Energy (Insulation) Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)
Engineering Final Inspection VOID 06/15/2022
Shannon King ((253) 840-6684)

Conditions

Condition Status Department Category Expiration Date Due Date
General Permit Conditions Resolved Building Division Standard Conditions
: * Final approval by the Building Official is required prior to use or occupancy. * Work shall not proceed until the inspector has approved the stages of construction. * Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties. * I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. * TO SCHEDULE INSPECTIONS, CHECK PERMIT STATUS OR TO MAKE PAYMENTS ON THE CITY WEB SITE VISIT https://secure.cityofpuyallup.org/
Engineering Commercial Standard Conditions Resolved Engineering Division Standard Conditions
: ** Occupancy will not be granted until the required frontage improvements have been completed and approved ** * Any addition/expansion to the foot print of the building including decks and porches not originally shown on the approved set of plans must obtain proper permits prior to construction * No work shall be done in or on the public right of way without a licensed and bonded contractor first obtaining a right of way permit. * Any code requirement that may have been overlooked in this plan review does not imply that the requirements have been waived.
Building Permit Standard Conditions Resolved Building Division Standard Conditions
: PERMIT CONDITIONS: 1- COMPLY WITH 2015 IFC AND 2015 IBC 2- TOTAL COVERAGE REQUIRED IN THE CITY OF PUYALLUP 3- EXIT LIGHTING TEST REQUIRED CONTRACTOR TO PROVIDE LIGHT METER 4- A SEPARATE PERMIT MAY BE REQUIRED IF FIRE ALARM OR SRPINKLER SYSTEM IS ALTERED 5- RTU'S WILL BE REQUIRED TO BE TESTED FOR SHUT DOWN. 6- FIRE EXTINGUISHERS REQUIRED PER CODE 7- ALL ABOVE ITEMS TO BE COMPLETED PRIOR TO FIRE FINAL. FIRE FINAL REQUIRED BEFORE BUILDING FINAL INSPECTION REQUEST CODES: 2252 EXIT LIGHT TEST 9200 FIRE BUILDING FINAL SCHEDULE YOUR INSPECTION BY PHONE OR ONLINE THROUGH THE CITY OF PUYALLUP ONLINE PERMIT SYSTEM. THEN CALL MORNING OF INSPECTION BETWEEN 7AM - 8PM TO SET UP A TIME. HTTPS://SECURE.CITYOFPUYALLUP.ORG/ INSPECTION LINE 1-877-232-6456 (USE MUTE TO AVOID BACKGROUND NOISE) DAVID DRAKE AT 253-864-4171 OR RAY COCKERHAM AT 253-841-5585
Pipeline Notfication Rcw 19.122.033 Resolved Engineering Division Standard Conditions
: Effective January 1, 2013 RCW 19.122 Before conducting any construction or excavation within 100 feet of a right-of-way or utility easement containing a transmission pipeline a person must notify the pipeline companies of the scheduled excavation through the one-number locator service 811. Notification must occur in a window of not less than 2 business days but not more than 10 business days before beginning the excavation. If a transmission pipeline company is notified that excavation work will occur near a pipeline, a representative of the company must consult with the excavator on-site prior to excavation.