Summary

E-20-0456
Franchise Utility Permit
Closed
TIPTON BARBARA L
Other
JOB # 186054605 REPLACES EXPIRED PERMIT E-19-0414 EXTENSION PROVIDED TO 5/1/21 CT EXTENSION PROVIDED TO 3/30/21 CT
09/30/2020
11/30/2020
05/01/2021
11/19/2021

Locations

Property
0419105020

* Address
1106 39TH AVE SE

Reviews

Review Type Outcome Est. Completion Date Completed
Legacy Activity (see Comments) Approved 11/19/2021
Engineering Review Approved 11/30/2020
Engineering Traffic Review Approved 11/30/2020

Fees

Paid Fees Amount Paid Owing Date Paid
E Franchise ROW Inspection Fee $130.00 $130.00 Paid 09/30/2020
No
Franchise Utility Review Fee $110.00 $110.00 Paid 09/30/2020
No
ROW Permit Fee $80.00 $80.00 Paid 09/30/2020
No
Franchise Traffic Control Fee $90.00 $90.00 Paid 09/30/2020
No
Legacy Fee $110.00 $110.00 Paid 09/30/2020
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Close All Restoration Complete Inspection Approved 11/19/2021
Legacy user

Conditions

Condition Status Department Category Expiration Date Due Date
General E-Permit For All Permits Resolved Engineering Division Standard Conditions
: JOB DESCRIPTION:
Private Utility Permit Conditions Resolved Engineering Division Standard Conditions
: *****PLEASE READ NEW PERMIT CONDITIONS***** ***SITE SPECIFIC CONDITIONS*** ** For TCP the necessitates the use of a police officer, Puyallup Police Officers will be utilized. Contact Tamara Ferrin at 253-841-5436 or via email at TAME@ci.puyallup.wa.us to coordinate. ** * Follow allowed work hours Tuesday through Thursday 9am-2pm and on Monday 10am-2pm. See attached bus schedule * * Where a curb exists, the lateral offset for all vertical obstructions shall be a minimum of 1.5' measured from the face of the obstruction pole to the face of curb. Where no curb exists, the lateral offset for all vertical obstructions shall be a minimum of 4' measured from the face of the obstruction to the edge of pavement. GENERAL CONDITIONS: 1. PERMIT AND APPROVED TRAFFIC CONTROL PLAN ARE REQUIRED TO BE AVAILABLE AT JOB SITE. NO PERMIT AT SITE SHALL BE SUBJECT TO TRIPLE PERMIT FEE. 2. Applicant/contractor shall notify the City within 5 days prior to work start date and also to close the permit when all work and restoration are complete and ready for final inspection. Go to: https://secure.cityofpuyallup.org/ and click on inspection requests to open the permit and schedule the inspection. Please select from the following codes: 6950 - PERMIT START 6955 - CLOSE ALL RESTORATION COMPLETE In lieu of online access, call the Inspection Request line at 1-877-232-6456. 3. Follow approved Traffic Control Plan (TCP) 4. 5. If a lane will be closed, call Comm Center at least 24 hours prior to closure at 253-841-5431. 6. Spotter must be available to assist with pedestrians if needed. 7. To schedule inspection, go to: Secure.cityofpuyallup.org and select appropriate code. 8. Please utilize traffic control information below for TCP: A. Distance between cones equals speed limit in unit feet. B. Taper length equals width of offset times speed limit squared divided by 60. L = WS² /60 - W= lane width S = speed limit C. Sign spacing shall be 100 feet when speed limit is 30 MPH or less D. Sign spacing shall be 350 feet when speed limit is greater than 30 MPH E. Distance between signs is mandatory unless field conditions determine otherwise. 9. DO NOT open cut without prior approval. 10. DO NOT park vehicles on city sidewalk. Curb, gutter or sidewalk damaged shall be replaced. 11. The Applicant shall defend, indemnify, and hold the City, its officers, employees and volunteers harmless from any and all claims, injuries, damages, losses or suits including attorney fees, arising out of or in connection with activities or operations performed by the Applicant or on the Applicant's behalf out of issuance of this
Pole Placement Resolved Engineering Division Standard Conditions
: Where a curb exists, the lateral offset for all vertical obstructions shall be a minimum of 1.5' measured from the face of the obstruction pole to the face of curb. Where no curb exists, the lateral offset for all vertical obstructions shall be a minimum of 4' measured from the face of the obstruction to the edge of pavement.