CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

F-18-0012


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

F-18-0012
Fire Alarms
Closed
IAC PORT 167 LLC
Other
(13) ALARMS ~ SERTA
02/22/2018
02/23/2018
02/23/2019
04/23/2018

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 02/23/2018

Fees

Paid Fees Amount Paid Owing Date Paid
Legacy Fee $260.00 $260.00 Paid 02/23/2018
No
Legacy Fee $230.00 $230.00 Paid 02/22/2018
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Fire Alarm Final Inspection In Progress 3/5/2018 03/05/2018
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Approved 04/23/2018
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Resolved Standard Conditions
1-PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 2-COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION 3-UPDATE THE DEVICE MAP AT THE ANNUNCIATOR AND FIRE ALARM PANELS 4-TOTAL COVERAGE IS REQURED; SUBJECT TO INSPECTION 5-FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED 6-A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 7-FIRE FINAL IS REQUIRED PRIOR TO BUILDING FINAL 8-CALL FOR BOTH FIRE ALARM PERMITS ON SAME DAY. F-17-0113, F-18-0012 INSPECTION REQUEST CODES: 5302 FIRE ALARM TEST INSPECTION 5303 FIRE ALARM FINAL INSPECTION 1.ANY NEW FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. 2. A DEVICE MAP WITH THE LAYOUT OF EACH FLOOR AND THE LOCATION AND DESCRIPTION OF EACH DEVICE INCLUDING THE POINT SHALL BE INSTALLED AT THE REMOTE ANNUNCIATOR AND THE MAIN FACP. THE EXTERIOR MAP SHALL BE NON-FADING AND NON-PEELING. 3. THE FIRE ALARM WIRING SHALL BE PERMITTED THROUGH LABOR AND INDUSTRIES AND THE PERMIT AND FINAL INSPECTIONS SHALL BE COMPLETED PRIOR TO FIRE FINAL TEST. 4. A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 5. FIRE FINAL INSPECTION IS REQUIRED PRIOR TO OCCUPANCY FIRE ALARM INSPECTION REQUEST CODES: 5302 FIRE ALARM TEST INSPECTION 5303 FIRE ALARM FINAL INSPECTION

Related Permit & Planning Applications

There are no related items for this development permit application.