F-18-0070


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

F-18-0070
Fire Alarms
Closed
CITY OF PUYALLUP
Other
(36) ALARMS ~ DAVITA DIALYSIS
09/13/2018
10/02/2018
10/02/2019
10/26/2018

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review VOID 12/09/2021
Fire Review Approved 09/28/2018

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $402.50 $402.50 Paid 09/13/2018
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Fire Alarm Cover Inspection Approved 10/17/2018 10/17/2018
David Drake ((253) 864-4171)
Fire Alarm Final Inspection In Progress 10/17/2018 10/17/2018
David Drake ((253) 864-4171)
Fire Alarm Test Inspection In Progress 10/17/2018 10/17/2018
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Approved 10/23/2018 10/23/2018
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Approved 10/23/2018 10/23/2018
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection VOID 10/16/2018 12/09/2021
David Drake ((253) 864-4171)
Fire Alarm Test Inspection VOID 10/16/2018 12/09/2021
David Drake ((253) 864-4171)
Fire Alarm Final Inspection VOID 10/16/2018 12/09/2021
David Drake ((253) 864-4171)

Conditions

Condition Status Department Category Expiration Date Due Date
New Fire Alarm System Conditions Resolved Standard Conditions
: 1- PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 2- COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION. 3- UPDATE THE DEVICE MAP AT THE ANNUNCIATOR AND FIRE ALARM PANEL PRIOR TO CALLING IN FINAL. THE ANNUNCIATOR MAP WILL NEED TO BE WEATHER PROOF. 4- TOTAL COVERAGE IS REQURED; SUBJECT TO FIELD INSPECTION. 5- FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED. 6- A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 7- FIRE FINAL IS REQUIRED PRIOR TO BUILDING FINAL. 8- REMOTE ANNUCIATOR LOCATED ON THE EXTERIOR REQUIRED. 9- DETECTION REQUIRED IN RISER ROOM NOT SHOWN ON PLAN 10- FIRE SPRINKLER TAMPER VALVES WILL NEED TO BE TESTED AT TIME OF INPSECITON ALONG WITH PIV. SPRINKLER CONTRACTOR REQUIRED TO BE ONSITE. 11- CONTRACTOR TO VERFIY ABOVE CEILING DEVICES ARE IN THE CORRECT PROXIMITY OF ALL 7 EXTERIOR STORAGE AREAS THAT ARE NOT SHOWN ON FIRE ALARM PLAN. IF DEVICE NEAREST STORAGE AREA DOESN'T MEET CODE, A NEW DEVICE SHALL BE INSTALLED IN STORAGE AREAS. UPDATED BATTERY CALCS AND AS-BULT WILL BE REQUIRED. INSPECTION REQUEST CODES: 5302 FIRE ALARM TEST INSPECTION 5303 FIRE ALARM FINAL INSPECTION SCHEDULE YOUR INSPECTION BY PHONE OR ONLINE THROUGH THE CITY OF PUYALLUP ONLINE PERMIT SYSTEM. THEN CALL MORNING OF INSPECTION BETWEEN 7AM - 8PM TO SET UP A TIME. CONTRACTOR MUST BE PRESENT. HTTPS://SECURE.CITYOFPUYALLUP.ORG/ INSPECTION LINE 1-877-232-6456 (USE MUTE TO AVOID BACKGROUND NOISE) DAVID DRAKE AT 253-864-4171 OR RAY COCKERHAM AT 253-864-4171

Related Permit & Planning Applications

There are no related items for this development permit application.