CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

F-18-0103


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

F-18-0103
Fire Alarms
Expired
VIKING JV LLC
Other
(180) ALARMS ~ VIKING JV LLC
12/06/2018
01/02/2019
12/20/2019

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 12/19/2018

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $517.50 $517.50 Paid 12/06/2018
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

There are no inspections for this development permit application, or you are not authorized to view them.

Conditions

Condition Status Category
New Fire Alarm System Conditions Resolved Standard Conditions
1- APPOINTMENT REQUIRED FOR INSPECTIONS. 2- PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 3- COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION. 4- AN EXTERIOR MOUNTED REMOTE ANNUCIATOR WILL BE REQUIRED ON THE SOUTH SIDE OF THE BUILDING IN A WEATHER PROOF HOUSING. SEE FIRE ALARM PLAN FOR DETAILS. 5- DEVICE MAPS REQUIRED AT THE ANNUNCIATOR AND FIRE ALARM PANEL PRIOR TO CALLING IN FINAL. THE ANNUNCIATOR MAP WILL NEED TO BE WEATHER PROOF. 6- EXTERIOR NOTIFICATION WILL BE REQUIRED ON THE SOUTH SIDE OF THE BUILDING 2/3 UP THE BUILDING FROM GROUND LEVEL. 7- TOTAL COVERAGE IS REQURED; SUBJECT TO FIELD INSPECTION. COMPLY WITH NFPA 72, 2013 8- FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED. 9- A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 10- FIRE SPRINKLER TAMPER VALVES, FIRE PUMP, AND PIV WILL BE REQUIRED TO BE TESTED AT INSPECTION. 11- THE CITY OF PUYALLUP ALLOWS ONE FACP PER BUILDING. THE PANEL WILL NEED TO BE LARGE ENOUGH TO HANDLE MULTIPLE TENTANTS. CONTRACTOR TO BE ONSITE. INSPECTION REQUEST CODES: 5302 FIRE ALARM TEST INSPECTION 5303 FIRE ALARM FINAL INSPECTION SCHEDULE YOUR INSPECTION BY PHONE OR ONLINE THROUGH THE CITY OF PUYALLUP ONLINE PERMIT SYSTEM. THEN CALL MORNING OF INSPECTION BETWEEN 7AM - 8PM TO SET UP A TIME. CONTRACTOR MUST BE PRESENT. HTTPS://SECURE.CITYOFPUYALLUP.ORG/ INSPECTION LINE 1-877-232-6456 (USE MUTE TO AVOID BACKGROUND NOISE) DAVID DRAKE AT 253-864-4171 OR RAY COCKERHAM AT 253-864-4171

Related Permit & Planning Applications

There are no related items for this development permit application.

Documents & Images

No documents are currently available for viewing.


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.