Summary

F-21-0034
Fire Alarms
Closed
IAC PORT 167 LLC
New
(1) SMOKE DETECTOR ~ SERTA SIMMONS
04/02/2021
04/27/2021
06/13/2022
12/15/2021

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 04/19/2021

Fees

Paid Fees Amount Paid Owing Date Paid
Legacy Fee $260.00 $260.00 Paid 04/21/2021
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
IFC Permit Inspection Comments 7/8/2021 07/07/2021
Monty Johnson ((253) 770-3326)
IFC Permit Inspection Not Ready 7/13/2021 07/20/2021
David Drake ((253) 864-4171)
IFC Permit Inspection Passed 12/15/2021 12/15/2021 12/15/2021
David Drake ((253) 864-4171)

Conditions

Condition Status Category
Resolved Standard Conditions
Building Division
REPLACEMENT DEVICE REQUIRED TO BE TESTED.
New Fire Alarm System Conditions Open Standard Conditions
Development & Permitting Services
1- APPOINTMENT REQUIRED FOR ALL INSPECTIONS 2- PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 3- COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION. 4- A REMOTE ANNUCIATOR LOCATED ON THE EXTERIOR OF THE MAIN ENTRANCE IN A WEATHER PROOF HOUSING REQUIRED. 5- EXTERIOR FIRE BELL REQUIRED OUTSIDE FIRE SPRINKLER ROOM. 6- DEVICE MAPS REQUIRED AT THE ANNUNCIATOR AND FIRE ALARM PANEL PRIOR TO CALLING IN FINAL. THE ANNUNCIATOR MAP WILL NEED TO BE WEATHER PROOF. 7- TOTAL COVERAGE IS REQURED; SUBJECT TO FIELD INSPECTION. COMPLY WITH NFPA 72, 2013 8- FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED. 9- A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 10- FIRE SPRINKLER TAMPER VALVES AND PIV WILL BE REQUIRED TO BE TESTED AT INSPECTION. FIRE SPRINKLER CONTRACTOR TO BE ONSITE. 11- THE CITY OF PUYALLUP ALLOWS ONE FACP PER BUILDING. THE PANEL WILL NEED TO BE LARGE ENOUGH TO HANDLE MULTIPLE TENTANTS IF APPLICABLE.