F-21-0114


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

F-21-0114
Fire Alarms
Canceled
STOF WA
Other
(151) FIRE ALARM ~ ADM/GASPARD BLDG 3.10.22 Subject: FW: Permit F-21-0114 - Pierce College Pierce College Gaspard ~ 650060409 -jf Hello, Inspector Drake is has advised that he will ask the permit techs to cancel our permit for Pierce College Gaspard ~ 650060409 is permit # F-21-0065. Janet can you let us know once cancelled? Thank you, Yvonne Thompson-Lemmon Project Coordinator II
10/08/2021
10/12/2021
08/29/2022
03/02/2022

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 10/11/2021

Fees

Paid Fees Amount Paid Owing Date Paid
Legacy Fee $517.50 $517.50 Paid 10/11/2021
No
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Fire Alarm Test Inspection Approved 10/26/2021 10/26/2021
Ray Cockerham ((253) 841-5585)
Fire Alarm Final Inspection Failed 10/26/2021 10/26/2021
Ray Cockerham ((253) 841-5585)

Conditions

Condition Status Department Category Expiration Date Due Date
New Fire Alarm System Conditions Resolved Standard Conditions
: 1- APPOINTMENT REQUIRED FOR ALL INSPECTIONS 2- PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 3- COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION. 4- DEVICE MAPS REQUIRED AT THE ANNUNCIATOR AND FIRE ALARM PANEL PRIOR TO CALLING IN FINAL. THE ANNUNCIATOR MAP WILL NEED TO BE WEATHER PROOF. 5- FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED. 6- A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 7- FIRE SPRINKLER TAMPER VALVES AND PIV WILL BE REQUIRED TO BE TESTED AT INSPECTION. FIRE SPRINKLER CONTRACTOR TO BE ONSITE. 8- THE CITY OF PUYALLUP ALLOWS ONE FACP PER BUILDING. THE PANEL WILL NEED TO BE LARGE ENOUGH TO HANDLE MULTIPLE TENTANTS IF APPLICABLE. INSPECTION REQUEST CODES: 5302 FIRE ALARM TEST INSPECTION 5303 FIRE ALARM FINAL INSPECTION SCHEDULE YOUR INSPECTION BY PHONE OR ONLINE THROUGH THE CITY OF PUYALLUP ONLINE PERMIT SYSTEM. THEN CALL MORNING OF INSPECTION BETWEEN 7AM - 8PM TO SET UP A TIME. CONTRACTOR MUST BE PRESENT. HTTPS://SECURE.CITYOFPUYALLUP.ORG/ INSPECTION LINE 1-877-232-6456 (USE MUTE TO AVOID BACKGROUND NOISE) DAVID DRAKE AT 253-864-4171 OR RAY COCKERHAM AT 253-841-5585