CITY OF PUYALLUP PERMITTING PORTAL
Permit Application Status
PRCTI20230388
Paid Fees | Amount | Paid | Owing | Date Paid |
---|---|---|---|---|
Fire Review Fee (Commercial Building) | $265.00 | $265.00 | Paid | 03/31/2023 |
Building Permit Fee | $708.75 | $708.75 | Paid | 03/31/2023 |
$734.75
|
||||
Mechanical Permit Fee | $40.00 | $40.00 | Paid | 03/31/2023 |
Building Plan Review Fee | $477.59 | $477.59 | Paid | 03/27/2023 |
Mechanical Plan Review Fee | $26.00 | $26.00 | Paid | 03/27/2023 |
WA State Building Code Council Fee (Commercial) | $25.00 | $25.00 | Paid | 03/31/2023 |
Outstanding Fees | Amount | Paid | Owing | Date Paid |
No outstanding fees. | ||||
Totals: | $1,542.34 | $1,542.34 | $0.00 |
Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.
$0.00
Inspection | Outcome | Requested | Scheduled | Date Inspected |
---|---|---|---|---|
Fire Or Smoke Damper Inspection | VOID | 04/07/2023 | ||
David Drake ((253) 864-4171) | ||||
Hydrostatic Test 200Lbs 2Hrs | VOID | 04/07/2023 | ||
David Drake ((253) 864-4171) | ||||
Emergency Radio Test Review Inspection | VOID | 04/07/2023 | ||
David Drake ((253) 864-4171) | ||||
Exit Lighting Test Inspection | Failed | 4/7/2023 | 04/07/2023 | |
David Drake ((253) 864-4171) | ||||
Fire Final Inspection | Not Ready | 4/7/2023 | 4/7/2023 | 04/07/2023 |
David Drake ((253) 864-4171) | ||||
Corrections:
Fire Final
Carried Forward
04/10/2023
Emergency lighting required. Provide emergency light test for next inspection.
|
||||
Erosion And Sediment Inspection | VOID | 04/07/2023 | ||
Michael Rosenau ((253) 344-6753) | ||||
Comment Engineering Div Inspection | VOID | 04/07/2023 | ||
Michael Rosenau ((253) 344-6753) | ||||
Engineering Final Inspection | Passed | 4/7/2023 | 4/7/2023 | 04/07/2023 |
Michael Rosenau ((253) 344-6753) | ||||
Building Final Inspection | Not Ready | 4/7/2023 | 4/7/2023 | 04/07/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
04/07/2023
1. provide fire approval prior to next inspection
2.provide rack signage as discussed on site
3. not ready
|
||||
Racking Anchors/Signage Inspection | Partial Pass | 4/7/2023 | 4/7/2023 | 04/07/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
04/07/2023
1. Anchorage approved per special inspection
2.provide signage on racks as discussed on site
|
||||
Building Final Inspection | Partial Pass | 5/9/2023 | 5/9/2023 | 05/09/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Resolved
05/09/2023
1. provide fire approval prior to next inspection
2.provide rack signage as discussed on site
3. not ready
|
||||
Other/Miscellaneous
Carried Forward
05/09/2023
1. provide fire final prior to calling in this inspection
2. ok to use all levels of racking
|
||||
Fire Final Inspection | Not Ready | 5/10/2023 | 5/10/2023 | 05/10/2023 |
David Drake ((253) 864-4171) | ||||
Corrections:
Fire Final
Carried Forward
05/10/2023
Emergency lighting required. Provide emergency light test for next inspection.
|
||||
Building Final Inspection | Not Ready | 5/10/2023 | 5/10/2023 | 05/10/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
05/10/2023
1. cancelled on site by contractor
|
||||
Building Final Inspection | Not Ready | 5/26/2023 | 5/26/2023 | 05/26/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
05/26/2023
1. provide fire final prior to calling in this inspection
2. ok to use all levels of racking
|
||||
Other/Miscellaneous
Carried Forward
05/26/2023
1. provide fire final prior to calling in this inspection
|
||||
Fire Final Inspection | Passed | 5/30/2023 | 5/30/2023 | 05/30/2023 |
David Drake ((253) 864-4171) | ||||
Corrections:
Fire Final
Outstanding
05/10/2023
Emergency lighting required. Provide emergency light test for next inspection.
|
||||
Building Final Inspection | Passed | 5/30/2023 | 5/30/2023 | 05/30/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Resolved
05/30/2023
1. cancelled on site by contractor
|
||||
Comment Building Div Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Footing/Setback Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Foundation/Rebar Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Underfloor Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Slab/Insulation Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Block Wall Rebar Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Roof Sheathing Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Shear Wall Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Firewall/Firestop Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Energy (Insulation) Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Frame Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Combination Frame And Rough In Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Ceiling Grid/T-Bar Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Wallboard / Drywall Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Re-Roof Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Hydronic Piping Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Refrigeration Line Test Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Exhaust Hood Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Light Test For Grease Duct Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Exhaust/Vent Fans Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Medical Gas Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Cover Inspection/Thrust Blocks Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Planning Final Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Exit Lighting Test Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Racking Anchors/Signage Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Outstanding
04/07/2023
1. Anchorage approved per special inspection
2.provide signage on racks as discussed on site
|
||||
Building Final Inspection | VOID | 05/30/2023 | ||
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Outstanding
05/26/2023
1. provide fire final prior to calling in this inspection
2. ok to use all levels of racking
|
||||
Other/Miscellaneous
Outstanding
05/26/2023
1. provide fire final prior to calling in this inspection
|
Condition | Status | Category |
---|---|---|
Building Permit Standard Conditions | Open | Standard Conditions |
Building Division
* Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
|
||
Fire Review Conditions | Open | Standard Conditions |
1. INSTALL ADDRESS NUMBERS PER THE FOLLOWING DISTANCES:0-50FOOT SETBACK FROM STREET NUMBERS SHALL BE 6 INCHES IN HEIGHT; 51-100 FEET 12 INCHES IN HEIGHT. ALL NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDITIONAL NUMBERS MAY BE NEEDED AT DRIVEWAY ENTRANCE IF BUILDING NUMBERS ARE NOT VISIBLE FROM THE STREET. REAR DOORS OF SUITES OR UNITS SHALL ALSO BE LABELED WITH MINIMUM 4 INCH NUMBERS.
2. FIRE HYDRANTS REQUIRED FOR CONSTRUCTION AND FIRE DEPARTMENT ACCESS SHALL BE INSTALLED AND APPROVED BY THE FIRE CODE OFFICIAL PRIOR TO THE STORAGE OR INSTALLATION OF ANY COMBUSTIBLE FRAMING MATERIAL. ACCESS ROADWAY SURFACES SHALL BE DESIGNED TO CITY STANDARDS AND BE DESIGNED TO MAINTAIN THE IMPOSED LOADS OF A 80,000 POUND FIRE APPARATUS. ASPHALT TREATED BASE, ASPHALT OR CONCRETE PAVEMENT CAN BE USED TO PROVIDE THE REQUIRED ALL-WEATHER DRIVING SURFACE.
3. ANY REQUIRED FIRE LANE MARKINGS SHALL BE INSTALLED PRIOR TO FINAL INSPECTION AND PER CITY ORDINANCE.
4. KNOX BOXES, WHEN REQUIRED, SHALL BE INSTALLED USUALLY TO THE RIGHT OF THE MAIN FRONT DOOR AND NO HIGHER THAN 6 FEET OFF OF THE GROUND. ONLY HINGED KNOX BOXES SHALL BE USED. KNOX BOXES AND KEY SWITCHES CAN BE ORDERED ONLINE AT THE "KNOX COMPANY"
5. FIRE EXTINGUISHERS WILL BE REQUIRED PER CHAPTER 9 OF THE INTERNATIONAL FIRE CODE. GENERALLY, 1 FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A 10BC SHALL BE INSTALLED PER EVERY 3,000 SQUARE FEET OF FLOOR AREA. THE LOCATION OF THE FIRE EXTINGUISHERS SHALL BE NEAR THE EXIT DOORS AND TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. ADDITIONAL SIGNAGE MAY BE NECESSARY TO INDICATE THE FIRE EXTINGUISHER LOCATION.
|
There are no related items for this permit application.
Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.
Powered by CityView
