Fire Alarms
Permit(s) Issued
WAL-MART RE BUSINESS TR 2403
Alteration/Remodel
T.I. add 14 devices in SE corner
07/27/2022
08/03/2022
07/30/2023

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
08/03/2022 2403 Puyallup WA SUB 07_25_22 (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 08/17/2022 08/02/2022

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $230.00 $230.00 Paid 07/27/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
1- APPOINTMENT REQUIRED FOR ALL INSPECTIONS 2- PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 3- COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION. 4- A REMOTE ANNUCIATOR LOCATED AT MAIN ENTRANCE . 5- Update DEVICE MAPS REQUIRED AT THE ANNUNCIATOR AND FIRE ALARM PANEL PRIOR TO CALLING IN FINAL. THE ANNUNCIATOR MAP WILL NEED TO BE WEATHER PROOF. 6- TOTAL COVERAGE IS REQURED; SUBJECT TO FIELD INSPECTION. COMPLY WITH NFPA 72, 2013 7- FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED. 8- A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 9- THE CITY OF PUYALLUP ALLOWS ONE FACP PER BUILDING. THE PANEL WILL NEED TO BE LARGE ENOUGH TO HANDLE MULTIPLE TENTANTS IF APPLICABLE.
Contaminated Site Remediation Open Standard Conditions
Engineering Division
The subject property has been classified as a contaminated site by the Tacoma Pierce County Health Department (TPCHD) and must be remediated per Washington Administrative Code Title 173. It is the applicant’s responsibility to coordinate cleanup with TPCHD. Visit https://www.tpchd.org/healthy-places/contaminated-property-cleanup for more information. The applicant shall request a remediation status report from TPCHD’s Rob Olsen by emailing him at rolsen@tpchd.org. Provide a copy of the status report to the City.

Related Permit & Planning Applications

There are no related items for this development permit application.

Documents & Images

Date Uploaded File Type Name
07/27/2022 Receipt Receipt for transaction:2022-001453
08/03/2022 Plans 2403 Puyallup WA CUT SHEETS 07_25_23 (Flattened)
08/03/2022 Form Fire Code Permit Application 0821_202108241006411506 (14)0 (Flattened)
08/03/2022 Plans 2403 Puyallup WA SUB 07_25_22 (Stamped)
08/03/2022 Permit Permit - Detailed
12/16/2022 Letter Permit Expiration Notice
06/14/2023 Letter Permit Expiration Notice


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.