Summary

PRFA20231716
Fire Alarms
Closed
WESTERN WASHINGTON FAIR ASSOCIATION
Replacement
1- ALARM WWF/FAIRVIEW CLUB BANQUET HALL @ 110 9th Ave SW
12/08/2023
01/05/2024
07/20/2024
01/22/2024

Locations

Property
0420331121

Address
110 9TH AVE SW, Unit: 10, PUYALLUP, WA 98371

110 9th Ave SW, Fair View Club Banquet Hall, Puyallup WA 98371

Reviews

Documents Returned For Corrections

Date Returned Name
01/05/2024 FIRE ALARM PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 01/10/2024 01/04/2024

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $132.25 $132.25 Paid 12/08/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection VOID 01/22/2024
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection VOID 01/22/2024
David Drake ((253) 864-4171)

Conditions

Condition Status Department Category Expiration Date Due Date
New Fire Alarm System Conditions Open Standard Conditions
: • Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • If there is an existing annunciator on the exterior of the building it will need to be moved inside the main entrance. Please contact fire inspector for further information. • Exterior fire bell required outside fire sprinkler room. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first. David Drake ddrake@puyallupwa.gov

Related Permit & Planning Applications

There are no related items for this development permit application.

Documents & Images

Date Uploaded File Type Name
12/08/2023 Plans FLOOR PLAN
12/08/2023 Plans DATA CUT SHEETS
12/08/2023 Plans CALCULATIONS
01/05/2024 Plans FIRE ALARM PLANS (Stamped)
12/08/2023 Receipt Receipt for transaction:2023-002311
01/05/2024 Permit Permit - Detailed
01/05/2024 Letter Permit Job Card


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.