CITY OF PUYALLUP PERMITTING PORTAL
Engineering Permit Application Status
PRAMR20251426
| Paid Fees | Amount | Paid | Owing | Date Paid |
|---|---|---|---|---|
| Alternative Method/Construct Fee | $250.00 | $250.00 | Paid | 10/30/2025 |
| Outstanding Fees | Amount | Paid | Owing | Date Paid |
| No outstanding fees. | ||||
| Totals: | $250.00 | $250.00 | $0.00 |
Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.
$0.00
There are no inspections for this engineering permit application, or you are not authorized to view them.
| Condition | Status | Category |
|---|---|---|
| Miscellaneous Condition | Open | |
|
Development & Permitting Services
The AMR is only for the Sewer and Water main locations within the ROW. All other City Standards still apply. [Lance Hollingsworth @ 11/06/2025 8:03 AM]
|
||
| Miscellaneous Condition | Open | |
|
Development & Permitting Services
The Water Division requires 3-foot separation between new 8-inch D.I. water and existing 4-inch W.I. (steel) water. Install 45-degree bends east of tie-in point to keep 10-foot separation between water and sewer mains. Existing 8-inch water main runs south out of intersection before transitioning to 4-inch. Water work can be done out of intersection. No need for 8-inch gate valve at tie-in location.
|
||
| Miscellaneous Condition | Open | |
|
Development & Permitting Services
The new 8-inch water main on 7th St SE will be shifted east to keep 3-foot separation between new 8-inch and existing 4-inch water. Keep the proposed 8-inch gate valve to the west and remove the 8-inch gate valve to the north. Maintain 3-foot separation between proposed 8-inch water and existing storm.
|
||
| Reference Number | Status | Type |
|---|---|---|
| PRCNC20250116 | Returned for Correction | Commercial - New Construction |
| PRCCP20250119 | Returned for Correction | Civil Construction Permit |
| PR20251457 | Canceled | |
| PR20251458 | Canceled | |
| P-21-0078 | File Closed | Pre-Application |
| PLCUP20220162 | Waiting for Conditions | Conditional Use Permit |
| Date Uploaded | File Type | Name |
|---|---|---|
| 10/30/2025 | Receipt | Receipt for transaction:2025-002101 |
| 11/14/2025 | Form | APPLICATION FORM (Stamped) |
| 11/14/2025 | Plans | SITE PLAN (Stamped) |
| 11/14/2025 | Form | AMR Approval or Denial Letter |
Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.
Powered by CityView