CITY OF PUYALLUP PERMITTING PORTAL

Engineering Permit Application Status

PRAMR20260675


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRAMR20260675
Alternative Methods / Materials Request
Ready for Issuance
WESTERN WASHINGTON FAIR ASSOCIATION
Not Applicable
The Fair is requesting deviation for private infrastructure from the City standards for the construction of Marcoe's candy building; please also refer to permit #PRCCP20260217. Work includes reconnecting utility services such as water, sewer, power, and gas to the new prefabricated building.
05/08/2026
11/09/2026

Locations

Property
0420331121

Reviews

There are no reviews for this permit application, or you are not authorized to view them.

Fees

Paid Fees Amount Paid Owing Date Paid
Alternative Method/Construct Fee $250.00 $250.00 Paid 05/08/2026
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

There are no inspections for this engineering permit application, or you are not authorized to view them.

Conditions

Condition Status Category
Miscellaneous Condition Open
Development & Permitting Services
Encase pipes or use DI where less than 3 feet of cover is unable to be achieved. Pipes shall still have a minimum 1 foot of cover. Encase pipes where 10 foot building separation is unable to be achieved. Pipes shall meet a minimum 5 feet of separation to allow for maintenance.
Miscellaneous Condition Open
Development & Permitting Services
Inspect existing sewer lateral to confirm it is in a serviceable condition.
Miscellaneous Condition Open
Development & Permitting Services
Provide sewer pipe flow calculations showing minimum design velocities are a minimum 2 fps flowing full.

Related Permit & Planning Applications

Reference Number Status Type
PRPF20251347 Returned for Correction Pre-Fabricated Building
PRCCP20260217 In Plan Check Civil Construction Permit
PRDE20260230 Permit(s) Issued Demolition
PRFS20260667 In Plan Check Fire Sprinklers
PLPRE20250047 File Closed Pre-Application

Documents & Images

Date Uploaded File Type Name
05/08/2026 Receipt Receipt for transaction:2026-000829