CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20221585


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20221585
Fire Alarms
Closed
MULTICARE HEALTH SYSTEM
Alteration/Remodel
Modify existing fire alrm system Good Samaritan Hospital, Level 1 East. Adding (5) relays, (1) notification device. Joint venture between Johnson Controls Fire Protection and Precision Electric Group.
10/10/2022
11/01/2022
09/04/2023
03/08/2023

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 10/31/2022 10/31/2022

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $132.25 $132.25 Paid 10/10/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection VOID 03/08/2023
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection VOID 03/08/2023
David Drake ((253) 864-4171)

Conditions

Condition Status Department Category Expiration Date Due Date
New Fire Alarm System Conditions Open Standard Conditions
: • Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

There are no related items for this development permit application.

Documents & Images

Date Uploaded File Type Name
03/06/2023 Letter Permit Expiration Notice
10/10/2022 Form Building Permit Application_
10/10/2022 Receipt Receipt for transaction:2022-002008
11/01/2022 Plans Battery Calcs Pages_Good Samaritan - Egress Doors Lvl 1 Rev 47 - JCI-FA-Dwgs - 2022-09-23 (Stamped)
11/01/2022 Plans Floor Plan Page_Good Samaritan - Egress Doors Lvl 1 Rev 47 - JCI-FA-Dwgs - 2022-09-23-2 (Stamped)
11/01/2022 Plans Good Samaritan - Egress Doors Lvl 1 Rev 47 - JCI-FA-Dwgs - 2022-09-23 (Stamped)
11/01/2022 Permit Permit - Detailed


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.