CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20221721


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20221721
Fire Alarms
Closed
CAFARO NORTHWEST PARTNERSHIP
Alteration/Remodel
(12) ALARMS NEW LEVEL 360 UNIT 900
11/04/2022
11/22/2022
07/16/2023
01/17/2023

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
11/22/2022 DRAWINGS (Stamped)
11/22/2022 battery calculations (Stamped)
11/22/2022 DRAWINGS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 11/27/2022 11/21/2022

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $132.25 $132.25 Paid 11/04/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Fire Alarm Final Inspection Not Ready 12/12/2022 12/12/2022 12/12/2022
David Drake ((253) 864-4171)
Piv And Tamper Inspection VOID 01/17/2023
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection VOID 01/17/2023
David Drake ((253) 864-4171)

Conditions

Condition Status Department Category Expiration Date Due Date
New Fire Alarm System Conditions Open Standard Conditions
: • Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

There are no related items for this development permit application.

Documents & Images

Date Uploaded File Type Name
11/04/2022 Receipt Receipt for transaction:2022-002212
11/04/2022 Letter Incomplete Application Notice
11/22/2022 Plans DRAWINGS (Stamped)
11/22/2022 Plans battery calculations (Stamped)
11/22/2022 Plans DRAWINGS (Stamped)
11/22/2022 Form Fire Code Permit Application 0821_202108241006411506 (Flattened)
11/22/2022 Permit Permit - Detailed