CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20250712


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20250712
Fire Alarms
Permit(s) Issued
CAFARO NORTHWEST PARTNERSHIP
Alteration/Remodel
We are adding smoke detector and strobes to the store. Also, connecting the existing Duct Detectors. (3500 S MERIDIAN, UNIT 800, PUYALLUP WA 98373) - BARNES & NOBLE
05/29/2025
06/27/2025
12/24/2025

Locations

Property
6021010051

6021010051
3500 S MERIDIAN, UNIT 800, PUYALLUP WA 98373

Reviews

Documents Returned For Corrections

Date Returned Name
06/27/2025 ALARM PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 06/27/2025 06/26/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $345.00 $345.00 Paid 05/29/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. Inspections are Monday - Thursday, no friday inspections • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Above ceiling detection is required. Bathroom will be in question at time of inspection unless existing devices in place. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72, 2016 • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • A pre-test shall be conducted and a printout of the location of the device, point number and descriptor shall be furnished to the inspector at final. Labeling of all devices above and below ceiling required. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20241136 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20250011 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRSG20250665 Ready for Issuance Sign/Awning
PRFS20250861 Permit(s) Issued Fire Sprinklers

Documents & Images

Date Uploaded File Type Name
05/29/2025 Plans CUT SHEETS
05/29/2025 Form APPLICATION
05/29/2025 Receipt Receipt for transaction:2025-001023
06/27/2025 Plans ALARM PLANS (Stamped)
06/27/2025 Permit Permit - Detailed
06/27/2025 Letter Permit Job Card


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.