CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20260856


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20260856
Fire Alarms
Permit(s) Issued
SAGE 400 LLC
Replacement
Replacing conventional fire alarm panel with a new addressable one - LEGEND AUTO SALES
06/18/2026
07/21/2026
01/17/2027

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
07/21/2026 ALARM PLANS (Stamped)
07/21/2026 CUT SHEETS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 07/20/2026 07/20/2026

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $402.50 $402.50 Paid 06/18/2026
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. Inspections are Monday - Thursday, no friday inspections • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Exterior fire bell required outside fire sprinkler room. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Fire alarm system shall be placarded per NFPA 72. • A pre-test shall be conducted and a printout of the location of the device, point number and descriptor shall be furnished to the inspector at final. Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20231570 Expired Commercial - Tenant Improvement/Remodel
PRCCP20231662 Expired Civil Construction Permit
PLPRE20230032 File Closed Pre-Application

Documents & Images

Date Uploaded File Type Name
06/18/2026 Receipt Receipt for transaction:2026-001101
07/21/2026 Plans ALARM PLANS (Stamped)
07/21/2026 Plans CUT SHEETS (Stamped)
07/21/2026 Permit Permit - Detailed


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.