PRFS20241391
Fire Sprinklers
Closed
MC DONALD CORP 41/46
Alteration/Remodel
RETROFIT EXISTING MCDONALD'S WITH NEW WET FIRE SPRINKLER SYSTEM.
09/04/2024
10/04/2024
06/02/2025
12/04/2024

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
10/03/2024 FIRE SPRINKLER PLANS (Stamped)
10/03/2024 CUT SHEET (Stamped)
10/03/2024 FLOOR PLAN (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 10/07/2024 10/03/2024

Fees

Paid Fees Amount Paid Owing Date Paid
Automatic Fire-Extinguishing System (New) Permit Fee $335.25 $335.25 Paid 10/04/2024
Automatic Fire-Extinguishing System (New) Plan Review Fee $217.91 $217.91 Paid 09/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Fire Sprinkler Cover Inspection Failed 11/7/2024 11/7/2024 11/07/2024
Ray Cockerham ((253) 841-5585)
Other/Miscellaneous
Carried Forward
11/07/2024
1) Complete riser from underground and bracing at same area. 2) Repair and secure insulation provide clearance to ALL sprinkler heads. 3) At South above drive through area add protection or fill cavity with secured insulation. 4) Over dining area - remove GWB obstruction left above new ACT ceiling or provide code reference related to the obstruction.

Fire Sprinkler Dry System Trip Test VOID 12/04/2024
David Drake ((253) 864-4171)

Conditions

Condition Status Department Category Expiration Date Due Date
Fire Sprinkler System (New) Conditions Open Standard Conditions
: • Provide plans and permit on site for inspection. • Cover and final inspections are required. • Contractor required at all inspections. • Hydro test will be required on all new and existing buildings. Appointment required. • Hydro test, two inspections will be required 2hrs apart. Call to schedule times. Am/pm is not guaranteed without appointment. • Tool kit required at time of final. • NFPA placards required. • Due to unforeseeable construction design, all head locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first. David Drake ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCA20231634 Permit(s) Issued Commercial - Addition
PRSG20240635 Closed Sign/Awning
PRHM20240695 Closed Hydraulic Modeling
PRCCP20240864 Permit(s) Issued Civil Construction Permit
PRFA20241433 Closed Fire Alarms
PRFS20241670 Closed Fire Sprinklers

Documents & Images

Date Uploaded File Type Name
09/04/2024 Receipt Receipt for transaction:2024-001820
09/09/2024 Plans SEISMIC CALC'S
09/09/2024 Plans SYSTEM CALCULATIONS
10/03/2024 Plans CUT SHEET (Stamped)
10/03/2024 Plans FIRE SPRINKLER PLANS (Stamped)
10/03/2024 Plans FLOOR PLAN (Stamped)
10/04/2024 Letter Permit - Detailed
10/04/2024 Receipt Receipt for transaction:2024-002086
11/07/2024 Report Inspection Report (Fire Sprinkler Cover Inspection)


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.