Summary

PRFS20251064
Fire Sprinklers
Permit(s) Issued
WRI-URS SOUTH HILL LLC
Alteration/Remodel
Modifying existing fire sprinkler system to accommodate new tenant walls & ceilings. - PLANET FITNESS
08/07/2025
09/04/2025
03/03/2026

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
09/04/2025 FIRE SPRINKLER PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 09/08/2025 09/04/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Automatic Fire Sprinkler System Alteration Fee $402.50 $402.50 Paid 08/07/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Hydrostatic Test 200Lbs 2Hrs Pending
David Drake ((253) 864-4171)
Fire Sprinkler Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Sprinkler Dry System Trip Test Pending
David Drake ((253) 864-4171)
Fire Sprinkler Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Category
Fire Sprinkler System (New) Conditions Open Standard Conditions
• Provide plans and permit on site for inspection. • Cover and final inspections are required. • Fire watch is required when sprinkler system is out of service in existing buildings. • Contractor required at all inspections. • Hydro test will be required on all new and existing buildings. Appointment required. • Hydro test, two inspections will be required 2hrs apart. Call to schedule times. Am/pm is not guaranteed without appointment • Fire pumps will be required to be tested and witnessed by inspector. • Tool kit required at time of final. • NFPA placards required • In existing buildings all upright fire sprinklers to remain, do not remove. • In existing buildings all required service and maintenance to be updated prior to inspection. • Due to unforeseeable construction design, all head locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20250853 In Plan Check Commercial - Tenant Improvement/Remodel
PRCTI20250870 Ready for Issuance Commercial - Tenant Improvement/Remodel
PRFA20251193 Permit(s) Issued Fire Alarms

Documents & Images

Date Uploaded File Type Name
08/07/2025 Plans FIRE SPRINKLER FLOOR PLAN
08/07/2025 Plans FIRE SPRINKLER CUT SHEET
08/07/2025 Receipt Receipt for transaction:2025-001554
08/08/2025 Letter Incomplete Submittal Notice
09/04/2025 Form Archer - Planet Fitness Puyallup - Permit Application (Flattened)
09/04/2025 Plans FIRE SPRINKLER PLANS (Stamped)
09/04/2025 Permit Permit - Detailed
09/04/2025 Letter Permit Job Card