CITY OF PUYALLUP PERMITTING PORTAL

Property Review

Assessors Parcel Number: 0420274127


Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Property Details

0420274127
Active
Section 27 Township 20 Range 04 Quarter 41 LOT 1 OF LOT COMB 2023-11-14-0590 THAT POR OF B 34 TO 37 OF REPLAT OF PART OF FRANK R SPINNING`S FIRST ADD LY NLY OF NP RR ROW TOG/W S 30 OF VAC PIONEER AVE ABUTTING B 34 & 35 PER ORD 211 TOG/W A PARCEL OF L
096
$4,614,300.00
$0.00
7.95

Addresses

Street # Pre-Direction Street Name Direction Unit # Status
240 15TH ST SE Active

Code Enforcement Complaints

No records were found.



Permit Applications

Application Number Type Work Class Status Date Issued
PRRWF20240390 Retaining Wall New Returned for Correction
: Retaining Wall

: Construct a lock and load retaining wall along the northwest boundary of property.
PRFO20240367 Foundation Only New Returned for Correction
: Foundation

: Construct a below grade concrete stormwater vault - FORTRESS PUYALLUP


Engineering Permit Applications

Application Number Type Work Class Status Date Issued
PRGR20250142 Clear, Fill, & Grade Permit New In Plan Check
: Civil


: Remedial excavations for removal and off-property disposal of soil contaminated with petroleum hydrocarbons and halogenated volatile organic compounds (HVOCs). Soil will be excavated from four localized areas on the property. The estimated area and volume for each excavation area is described below: Excavation Area 1: 300sqft to a depth of 2 feet below ground surface (bgs) (~24 cubic yards) Excavation Area 2: 300sqft to a depth of 10 feet bgs (~112 cubic yards) Excavation Area 3: 800sqft to a depth of 5 feet bgs (~147 cubic yards) Excavation Area 4: 800sqft to a depth of 5 feet bgs (~147 cubic yards) Remedial excavations will be conducted in areas currently covered by concrete or asphalt surfaces. Groundwater is not anticipated to be encountered during excavation, and no excavation dewatering is planned. Any water generated during excavation activities will be pumped into a tank for off-Property disposal and will not be discharged to the municipal stormwater or sewer systems.Following completion of excavation activities, each excavation area will be backfilled with imported clean fill and completed at the surface with crushed rock to stabilize the site and match the surrounding grade.
PRFUP20240445 Franchise Utility Permit Utility Closed 04/08/2024
: Franchise Utility Permit


: Work in ROW to wreck out of OH wires across 15th St SE @ P02-P01 568217-155912 & 568221-155918.
PRCWSA20240364 Certificate of Water/Sewer Availability Not Applicable Closed 04/16/2024
: Certificate of Water Availability


: Design and installation of fire sprinkler system - FORTRESS PUYALLUP


Development Permit Applications

No records were found.



Planning Applications

No records were found.








NOTE: APPLICATIONS WILL NOT BE PROCESED UNTIL ALL REQUIRED SUBMITTAL ITEMS HAVE BEEN UPLOADED AND ALL APPLICATION INTAKE FEES HAVE BEEN PAID.