CITY OF PUYALLUP PERMITTING PORTAL

Property Review

Assessors Parcel Number: 6865000058


Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Property Details

6865000058
Active
Section 34 Township 20 Range 04 Quarter 21 PETERSONS: PETERSONS S 142.5 FT OF L 4, S 143 FT OF L 5 ALL OF L 6 THRU 8 SEG G 4060 CHECK UND INT PER ETN 640779 & 647350 (DC0951ES10-14-85 & DC1881ES2-19-86) UND INT PER 663345 (DC3799ES11-20-86)
096
$2,313,200.00
$3,151,100.00
2.91

Addresses

Street # Pre-Direction Street Name Direction Unit # Status
511 10TH AVE SE Active

Contacts

Type Description
Property Owner VALLEY TERRACE MED INVESTORS LLC, Address:3001 KEITH ST NW
Historic Owner Not shown for privacy reasons
Historic Owner Not shown for privacy reasons
Historic Owner Not shown for privacy reasons
Historic Owner Not shown for privacy reasons
Historic Owner Not shown for privacy reasons
Historic Owner Not shown for privacy reasons
Historic Owner Not shown for privacy reasons

Code Enforcement Complaints

No records were found.



Permit Applications

Application Number Type Work Class Status Date Issued
PRPL20260690 Plumbing - COMMERCIAL ONLY Alteration/Remodel Submittals Incomplete
: Plumbing

: • Temporarily connect the hot water supply and hot water to the building connections on 1 existing hot water storage tank to allow the system to remain in service while the tank is removed. • Furnish and install 2 new AO Smith TJV120 domestic hot water 119-gallon vertical storage tanks in the adjacent room to the existing boilers. • Furnish and install new correctly sized temperature and pressure relief valves on the new storage tanks with the relief lines routed to the nearest drain. • Seismic strapping of the new storage tanks. • Relocate the existing aquastat to the new storage tanks to reduce the short cycling of the new boilers. • Furnish and install 1 new Heat-Timer domestic hot water mixing valve designed to supply the current domestic hot water needs for the facility. • Furnish and install 1 new circulation pump which is properly sized to meet the requirements of the facility. • Furnish and install 1 new expansion tank sized to meet the needs of the facility. • Disconnect and remove the existing domestic hot water boiler in the mechanical room. • Relocate the existing AO Smith HW-670 boiler to the prior location of the domestic hot water boiler. • Revise and make corrections to the cold water, hot water, natural gas, flue, relief valves, and electrical to meet the manufacturers requirements and current code requirements. This includes ball valves, unions, gauges, and check valves in the required locations. • Electrical modifications. • Fire stopping of the plumbing penetrations. • Plumbing permit. • Regular labor hours. • Engineered drawings for permit submission. • Decommission the 3 existing hot water storage tanks in the lower-level space. The piping will be cut and capped and the tanks drained. • Coordinate the water shutdown times to minimize facility impacts.
F-17-0120 UNKOWN LEGACY PERMIT TYPE Other Closed 12/12/2017
: Building

: (1) HOOD SUPPRESSION ~ LIFE CENTER
B-16-0685 Commercial - New Construction Other Closed 08/08/2016
: Building

: REPAIR POST (6X6) & REANCHOR BEAM SUBJECT TO FIELD INSPECTION ~ LIFE CENTER
B-16-0551 Commercial - New Construction Other Closed 06/30/2016
: Building

: CONCRETE PAD 78SQ FT FOR GENERATOR ~ LIFE CARE OF PUYALLUP 4.17.17 permit extension;pd permit fee *
B-16-0272 Mechanical - COMMERCIAL ONLY Other Expired 06/08/2016
: Mechanical

: RTU ~ LIFE CARE CTR OF PUYALLUP
B-13-0511 Mechanical - COMMERCIAL ONLY Other Expired 06/21/2013
: Mechanical

: REPLACE HEAT PUMP LIKE FOR LIKE ~ LIFE CARE CTR
B-10-0462 Mechanical - COMMERCIAL ONLY Other Expired
: Mechanical

: COMM MECH (2) ROOFTOP UNITS - LIKE FOR LIKE
B-09-0105 Mechanical/Plumbing - RESIDENTIAL ONLY Other Closed 02/05/2009
: Building

: REPLACE ROOFTOP HEAT PUMP UNIT - LIKE FOR LIKE


Engineering Permit Applications

Application Number Type Work Class Status Date Issued
E-12-0030 Alternative Methods / Materials Request Other Closed 03/05/2012
: Engineering


: INSTALL PERVIOUS CONCRETE SIDEWALK
E-12-0029 Alternative Methods / Materials Request Other Closed 03/05/2012
: Engineering


: MINIMUM DRIVEWAY SPACING


Development Permit Applications

Application Number Type Work Class Status Date Issued
F-16-0078 Fire Construction Permit Other Closed 12/16/2016
: Fire


: REPLACE EXISTING GENERATOR ~ LIFE CARE OF PUYALLUP
F-13-0058 Fire Sprinklers Other Canceled 08/19/2013
: Fire


: (3) SPRINKLERS ~ LIFE CARE CENTER
F-13-0036 Fire Sprinklers Other Expired 05/16/2013
: Fire


: (8) FIRE SPRINKLERS ~ TI/LIFE CARE CENTER


Planning Applications

Project Number Type Status Date Closed
P-11-0040 Pre-Application Expired 08/30/2011
: LIFE CARE CENTER
P-11-0013 Pre-Application Expired
: LIFE CARE CENTER OF PUYALLUP







NOTE: APPLICATIONS WILL NOT BE PROCESED UNTIL ALL REQUIRED SUBMITTAL ITEMS HAVE BEEN UPLOADED AND ALL APPLICATION INTAKE FEES HAVE BEEN PAID.