CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20221928


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20221928
Fire Alarms
Closed
CAFARO NORTHWEST PARTNERSHIP
Alteration/Remodel
INSTALLATION OF REMOTE TEST STATIONS ON ALL EXISTING DUCT DETECTORS. INSTALL NEW PULL STATION FOR NEW EGRESS DOOR. INSTALL NEW SMOKE DETECTORS TO ACCOMODATE FOR NEW DEMISING WALL. RELOCATE EXISTING DEVICES FOR OLD RESTROOM AREA THAT IS BEING DEMOLISHED. NEW LEVEL 360 UNIT 900-20
12/28/2022
01/19/2023
08/27/2023
02/28/2023

Locations

Reviews

Documents Returned For Corrections

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 01/17/2023 01/18/2023

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $230.00 $230.00 Paid 12/28/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection VOID 07/05/2023
Joyce Kennedy ((253) 841-5405)
Fire Alarm Cover Inspection VOID 07/05/2023
Joyce Kennedy ((253) 841-5405)
Fire Alarm Test Inspection VOID 07/05/2023
Joyce Kennedy ((253) 841-5405)

Conditions

Condition Status Department Category Expiration Date Due Date
New Fire Alarm System Conditions Open Standard Conditions
: • Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20221551 Closed Commercial - Tenant Improvement/Remodel
PRCTI20230029 Closed Commercial - Tenant Improvement/Remodel

Documents & Images


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.