CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20230883


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20230883
Fire Alarms
Closed
AMB INSTITUTIONAL ALLIANCE FUND III LP
Alteration/Remodel
Install new fire alarm devices in new office TI, tie into existing system. - PROLOGIS SUITE 103
06/13/2023
07/20/2023
07/14/2025
01/07/2025

Locations

Reviews

Documents Returned For Corrections

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 07/25/2023 07/20/2023
Fire Review Failed 07/14/2023 06/30/2023

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $345.00 $345.00 Paid 06/13/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Fire Alarm Final Inspection Partial Pass 1/8/2024 1/8/2024 01/10/2024
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Resolved
01/07/2025
Testing in office space is complete suite 103. 1) Need updated map. 2) Review Certificate 3) Above ceiling system has been disabled.

Fire Alarm Final Inspection Passed 1/7/2025 1/7/2025 01/07/2025
David Drake ((253) 864-4171)
Corrections:


Other/Miscellaneous
Resolved
01/07/2025
Testing in office space is complete suite 103. 1) Need updated map. 2) Review Certificate 3) Above ceiling system has been disabled.

Piv And Tamper Inspection VOID 01/07/2025
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection VOID 01/07/2025
David Drake ((253) 864-4171)
Fire Alarm Test Inspection VOID 01/07/2025
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • If there is an existing annunciator on the exterior of the building it will need to be moved inside the main entrance. Please contact fire inspector for further information. • Exterior fire bell required outside fire sprinkler room. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20230310 Closed Commercial - Tenant Improvement/Remodel
PRUSR20230614 Closed Utility Service Repair/PRIVATE PROPERTY ONLY
PRFS20230864 Expired Fire Sprinklers
PRFA20231139 Closed Fire Alarms
PRFA20231193 Closed Fire Alarms
PRCTI20240469 Closed Commercial - Tenant Improvement/Remodel
PRFS20240702 Permit(s) Issued Fire Sprinklers
PRCTI20250557 Closed Commercial - Tenant Improvement/Remodel
PRSG20250891 Closed Sign/Awning
PRCTI20251104 Ready for Issuance Commercial - Tenant Improvement/Remodel
PRCTI20251201 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRSG20251300 Permit(s) Issued Sign/Awning
PRFA20251359 In Plan Check Fire Alarms

Documents & Images

Date Uploaded File Type Name
06/13/2023 Form Prologis Park 103 Fire Alarm Application
06/13/2023 Receipt Receipt for transaction:2023-001108
07/11/2023 Letter Permit Review Correction Letter
07/11/2023 Form prologis Park Suite 103 Resbmittal Letter
07/20/2023 Plans (7-7-23) Prologis Puyallup Suite 103 FA Drawings (Stamped)
07/20/2023 Plans Prologis Puyallup Suite 103 Fire Alarm Submittals (Stamped)
07/20/2023 Permit Permit - Detailed
12/05/2023 Letter Permit Expiration Notice
06/06/2024 Letter Permit Expiration Notice
12/06/2024 Letter Permit Expiration Notice


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.