Summary

PRCTI20230310
Commercial - Tenant Improvement/Remodel
Closed
AMB INSTITUTIONAL ALLIANCE FUND III LP
Alteration/Remodel
±130,912 SF, NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT: WORK INCLUDES NON-STRUCTURAL DEMOLITION, NEW PARTITIONS, DOORS, AND FINISHES.
03/13/2023
06/08/2023
04/01/2025
10/03/2024

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Planning Review Approved 06/08/2023 06/07/2023
Design Review VOID 06/08/2023 06/07/2023
Fire Review Approved 06/08/2023 06/06/2023
Building Review Approved 06/08/2023 05/31/2023
Engineering Traffic Review Approved 06/08/2023 05/26/2023
Engineering Review Approved 06/08/2023 05/24/2023
Planning Review Approved 04/20/2023 04/21/2023
Design Review VOID 04/20/2023 04/21/2023
Building Review Failed 04/20/2023 04/17/2023
Fire Review Approved 04/20/2023 04/17/2023
Engineering Review Approved 04/20/2023 03/29/2023
Engineering Traffic Review Approved 04/20/2023 03/24/2023

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Review Fee (Commercial Building) $265.00 $265.00 Paid 06/08/2023
Building Permit Fee $1,553.75 $1,553.75 Paid 06/08/2023
Building Plan Review Fee $1,009.94 $1,009.94 Paid 03/14/2023
WA State Building Code Council Fee (Commercial) $25.00 $25.00 Paid 06/08/2023
Air Handling Unit (Up to 10,000 cfm) Fee $14.10 $14.10 Paid 06/08/2023
Mechanical Duct Work Fee $24.00 $24.00 Paid 06/08/2023
Mechanical Permit Fee $40.00 $40.00 Paid 06/08/2023
Mechanical Plan Review Fee $50.77 $50.77 Paid 06/08/2023
Resubmittal Fee $180.00 $180.00 Paid 05/23/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Frame Inspection Not Ready 7/5/2023 7/5/2023 07/05/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
07/05/2023
1. provide full size color city approved plan on site at time of next inspection

Frame Inspection Not Ready 7/7/2023 7/7/2023 07/07/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
07/07/2023
1. provide full size color city approved plan on site at time of next inspection

Other/Miscellaneous
Carried Forward
07/07/2023
1. no access building was locked 11:06 am at time of inspection

Frame Inspection Partial Pass 7/10/2023 7/10/2023 07/10/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Resolved
07/10/2023
1. provide full size color city approved plan on site at time of next inspection

Other/Miscellaneous
Resolved
07/10/2023
1. no access building was locked 11:06 am at time of inspection

Wallboard / Drywall Inspection Passed 7/14/2023 7/14/2023 07/14/2023
Ray Cockerham ((253) 841-5585)
Energy (Insulation) Inspection Passed 7/14/2023 7/14/2023 07/14/2023
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Resolved
07/14/2023
R 13 insulation demising wall completed per plan

Mechanical Rough In Inspection Partial Pass 7/14/2023 7/14/2023 07/14/2023
Ray Cockerham ((253) 841-5585)
Shear Wall Inspection Partial Pass 7/19/2023 7/19/2023 07/19/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
07/19/2023
1. partial approval as marked up on plans sheet AI101

Mechanical Rough In Inspection Partial Pass 8/3/2023 8/3/2023 08/03/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
08/03/2023
1. ok to insulate duct as discussed 2.no seismic was in place at time of inspection 3.smoke damper was not in place at time of inspection 4. cold air return drops where not installed at time of inspection

Shear Wall Inspection Partial Pass 8/14/2023 8/14/2023 08/14/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
08/14/2023
1. partial approval as marked up on plans sheet AI101

Other/Miscellaneous
Carried Forward
08/14/2023
1. treated plywood completed and approved

Shear Wall Inspection Partial Pass 8/16/2023 8/16/2023 08/16/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
08/16/2023
1. partial approval as marked up on plans sheet AI101

Other/Miscellaneous
Carried Forward
08/16/2023
1. treated plywood completed and approved

Other/Miscellaneous
Carried Forward
08/16/2023
1. vapor barrier approved

Shear Wall Inspection Partial Pass 8/21/2023 8/21/2023 08/21/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
08/21/2023
1. partial approval as marked up on plans sheet AI101

Other/Miscellaneous
Carried Forward
08/21/2023
1. treated plywood completed and approved

Other/Miscellaneous
Carried Forward
08/21/2023
1. vapor barrier approved

Other/Miscellaneous
Carried Forward
08/21/2023
1. rigid foam approved

Shear Wall Inspection Not Ready 8/28/2023 8/28/2023 08/28/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
08/28/2023
1. partial approval as marked up on plans sheet AI101

Other/Miscellaneous
Carried Forward
08/28/2023
1. treated plywood completed and approved

Other/Miscellaneous
Carried Forward
08/28/2023
1. vapor barrier approved

Other/Miscellaneous
Carried Forward
08/28/2023
1. rigid foam approved

Other/Miscellaneous
Carried Forward
08/28/2023
1.cancelled by contractor

Shear Wall Inspection Partial Pass 8/30/2023 8/30/2023 08/30/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
08/30/2023
1. partial approval as marked up on plans sheet AI101

Other/Miscellaneous
Carried Forward
08/30/2023
1. treated plywood completed and approved

Other/Miscellaneous
Carried Forward
08/30/2023
1. vapor barrier approved

Other/Miscellaneous
Carried Forward
08/30/2023
1. rigid foam approved

Other/Miscellaneous
Carried Forward
08/30/2023
1.cancelled by contractor

Other/Miscellaneous
Carried Forward
08/30/2023
1. furring strip attachment approved 8/30/2023

Shear Wall Inspection Failed 9/11/2023 9/11/2023 09/11/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
09/11/2023
1. partial approval as marked up on plans sheet AI101

Other/Miscellaneous
Carried Forward
09/11/2023
1. treated plywood completed and approved

Other/Miscellaneous
Carried Forward
09/11/2023
1. vapor barrier approved

Other/Miscellaneous
Carried Forward
09/11/2023
1. rigid foam approved

Other/Miscellaneous
Carried Forward
09/11/2023
1.cancelled by contractor

Other/Miscellaneous
Carried Forward
09/11/2023
1. furring strip attachment approved 8/30/2023

Other/Miscellaneous
Carried Forward
09/11/2023
1. removed 5 sheets of drywall to verify seams breaking on furring strips per city approved plans 3 locations did not. provide clarification from architect that what is on site is acceptable to his design 2. there was no drywall nailing looked at at time of inspection date 09/11/2023

Shear Wall Inspection Partial Pass 9/13/2023 9/13/2023 09/14/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
09/14/2023
1. partial approval as marked up on plans sheet AI101

Other/Miscellaneous
Carried Forward
09/14/2023
1. treated plywood completed and approved

Other/Miscellaneous
Carried Forward
09/14/2023
1. vapor barrier approved

Other/Miscellaneous
Carried Forward
09/14/2023
1. rigid foam approved

Other/Miscellaneous
Carried Forward
09/14/2023
1.cancelled by contractor

Other/Miscellaneous
Carried Forward
09/14/2023
1. furring strip attachment approved 8/30/2023

Other/Miscellaneous
Resolved
09/14/2023
1. removed 5 sheets of drywall to verify seams breaking on furring strips per city approved plans 3 locations did not. provide clarification from architect that what is on site is acceptable to his design 2. there was no drywall nailing looked at at time of inspection date 09/11/2023

Other/Miscellaneous
Carried Forward
09/14/2023
1. letter from architect regarding furring strips approved 2.drywall approved for tapping

Ceiling Grid/T-Bar Inspection Not Ready 10/10/2023 10/10/2023 10/10/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
10/10/2023
1. complete all ceiling requirements as discussed with contractor

Mechanical Final Inspection Not Ready 10/11/2023 10/11/2023 10/11/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
10/11/2023
1:complete screws in diffusers 2:provide electrical final 3:provide balance report to include osa

Mechanical Rough In Inspection Partial Pass 10/23/2023 10/23/2023 10/23/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Resolved
10/23/2023
1. ok to insulate duct as discussed 2.no seismic was in place at time of inspection 3.smoke damper was not in place at time of inspection 4. cold air return drops where not installed at time of inspection

Other/Miscellaneous
Carried Forward
10/23/2023
1. diffusers at ceiling grid approved

Mechanical Final Inspection Not Ready 10/23/2023 10/23/2023 10/23/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
10/23/2023
1.not ready

Ceiling Grid/T-Bar Inspection Not Ready 10/23/2023 10/23/2023 10/24/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
10/24/2023
1. complete all ceiling requirements as discussed with contractor

Other/Miscellaneous
Carried Forward
10/24/2023
1.complete perimeter wires as discussed with contractor 2. complete positive attachment to light fixtures as discussed with contractor 3.provide BIRC clips as discussed with contractor 4.provide electrical cover approval at time of next inspection

Ceiling Grid/T-Bar Inspection Failed 10/30/2023 10/30/2023 10/30/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
10/30/2023
1. complete all ceiling requirements as discussed with contractor

Other/Miscellaneous
Carried Forward
10/30/2023
1.complete perimeter wires as discussed with contractor 2. complete positive attachment to light fixtures as discussed with contractor 3.provide BIRC clips as discussed with contractor 4.provide electrical cover approval at time of next inspection

Other/Miscellaneous
Carried Forward
10/30/2023
1. provide electrical cover approval from previous inspection

Frame Inspection Partial Pass 10/31/2023 10/31/2023 10/31/2023
Kevin Spruell ((253) 841-5590)
Fire Final Inspection Not Ready 12/21/2023 12/21/2023 12/21/2023
David Drake ((253) 864-4171)
Corrections:


Other/Miscellaneous
Carried Forward
12/21/2023
Items discussed. 1. Fire Alarm, devices above ceiling, missing detection warehouse bathroom hallway, and all documentation. 2. Fire Sprinkler final requirements. 3. Emergency Lighting, tested the circuit, missing lighting throughout office space, warehouse half the lights works, half the bug eyes work. 4. All fire extinguishers have been removed, reinstall all through warehouse and office space.

Fire Final Inspection Not Ready 3/8/2024 3/8/2024 03/08/2024
David Drake ((253) 864-4171)
Corrections:


Other/Miscellaneous
Carried Forward
03/08/2024
Items discussed. 1. Fire Alarm, devices above ceiling, missing detection warehouse bathroom hallway, and all documentation. 2. Fire Sprinkler final requirements. 3. Emergency Lighting, tested the circuit, missing lighting throughout office space, warehouse half the lights works, half the bug eyes work. 4. All fire extinguishers have been removed, reinstall all through warehouse and office space.

Other/Miscellaneous
Carried Forward
03/08/2024
1. All of the original work has been removed. Project was taken to ceiling cover prior to second demo. 2. Fire Sprinkler permit is expired, apply for a new permit once new scope of work has been designed. 3. L&i permit will be required prior to inspections since everything was demoed for a second time. 4. Fire Alarm Devices will need to be reinstalled above ceiling. Install devices at roof deck for code compliance immediately. 5. Apply for a new Building T.I. permit under the 2021 codes unless a complete submittal can be excepted prior to March 15th. 6. Architect required to address energy code requirements along with a mechanical engineer. I would suggest onsite visits for all subs starting over. 7. All mechanical and lighting that is not installed per the manufactures install methods needs to be secured or removed for safety. 8. Below ceiling sprinkler system can be capped while work is completed above. The below ceiling fire sprinkler system is only required once the drop tiles are in place. 9. Permit Center has been notified of the changes.

Ceiling Grid/T-Bar Inspection Not Ready 3/8/2024 3/8/2024 03/08/2024
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Resolved
03/08/2024
1. complete all ceiling requirements as discussed with contractor

Other/Miscellaneous
Resolved
03/08/2024
1.complete perimeter wires as discussed with contractor 2. complete positive attachment to light fixtures as discussed with contractor 3.provide BIRC clips as discussed with contractor 4.provide electrical cover approval at time of next inspection

Other/Miscellaneous
Resolved
03/08/2024
1. provide electrical cover approval from previous inspection

Other/Miscellaneous
Carried Forward
03/08/2024
1. this was a comment inspection 2.provide new plans for new scope of work submit to city and obtain new permits as discussed with contractor

Comment Building Div Inspection Not Ready 4/25/2024 4/25/2024 04/25/2024
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
04/25/2024
1. discussed new permit old permit and current scope of work

Mechanical Rough In Inspection Partial Pass 7/23/2024 7/23/2024 07/23/2024
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
07/23/2024
1. diffusers at ceiling grid approved

Other/Miscellaneous
Carried Forward
07/23/2024
insulated duct work ok

Engineering Final Inspection Passed 09/06/2024
Michael Rosenau ((253) 344-6753)
Comment Engineering Div Inspection Passed 09/06/2024
Michael Rosenau ((253) 344-6753)
Erosion And Sediment Inspection Passed 09/06/2024
Michael Rosenau ((253) 344-6753)
Elevation Verification Inspection VOID 09/06/2024
Michael Rosenau ((253) 344-6753)
Floodproof Certification Inspection VOID 09/06/2024
Michael Rosenau ((253) 344-6753)
Building Final Inspection Failed 9/9/2024 9/9/2024 09/09/2024
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
09/09/2024
date of inspection 9/9/2024 1.complete roof repairs as discussed with contractor

Building Final Inspection Passed 9/12/2024 9/12/2024 10/03/2024
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Resolved
10/03/2024
date of inspection 9/9/2024 1.complete roof repairs as discussed with contractor

Footing/Setback Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Foundation/Rebar Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Underfloor Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Slab/Insulation Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Block Wall Rebar Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Firewall/Firestop Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Re-Roof Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Refrigeration Line Test Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Exhaust/Vent Fans Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Fire Or Smoke Damper Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Cover Inspection/Thrust Blocks Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Hydrostatic Test 200Lbs 2Hrs VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Emergency Radio Test Review Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Planning Final Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Shear Wall Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Outstanding
09/14/2023
1. partial approval as marked up on plans sheet AI101

Other/Miscellaneous
Outstanding
09/14/2023
1. treated plywood completed and approved

Other/Miscellaneous
Outstanding
09/14/2023
1. vapor barrier approved

Other/Miscellaneous
Outstanding
09/14/2023
1. rigid foam approved

Other/Miscellaneous
Outstanding
09/14/2023
1.cancelled by contractor

Other/Miscellaneous
Outstanding
09/14/2023
1. furring strip attachment approved 8/30/2023

Other/Miscellaneous
Outstanding
09/14/2023
1. letter from architect regarding furring strips approved 2.drywall approved for tapping

Mechanical Final Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Outstanding
10/23/2023
1.not ready

Frame Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Fire Final Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Outstanding
03/08/2024
Items discussed. 1. Fire Alarm, devices above ceiling, missing detection warehouse bathroom hallway, and all documentation. 2. Fire Sprinkler final requirements. 3. Emergency Lighting, tested the circuit, missing lighting throughout office space, warehouse half the lights works, half the bug eyes work. 4. All fire extinguishers have been removed, reinstall all through warehouse and office space.

Other/Miscellaneous
Outstanding
03/08/2024
1. All of the original work has been removed. Project was taken to ceiling cover prior to second demo. 2. Fire Sprinkler permit is expired, apply for a new permit once new scope of work has been designed. 3. L&i permit will be required prior to inspections since everything was demoed for a second time. 4. Fire Alarm Devices will need to be reinstalled above ceiling. Install devices at roof deck for code compliance immediately. 5. Apply for a new Building T.I. permit under the 2021 codes unless a complete submittal can be excepted prior to March 15th. 6. Architect required to address energy code requirements along with a mechanical engineer. I would suggest onsite visits for all subs starting over. 7. All mechanical and lighting that is not installed per the manufactures install methods needs to be secured or removed for safety. 8. Below ceiling sprinkler system can be capped while work is completed above. The below ceiling fire sprinkler system is only required once the drop tiles are in place. 9. Permit Center has been notified of the changes.

Ceiling Grid/T-Bar Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Outstanding
03/08/2024
1. this was a comment inspection 2.provide new plans for new scope of work submit to city and obtain new permits as discussed with contractor

Comment Building Div Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Outstanding
04/25/2024
1. discussed new permit old permit and current scope of work

Mechanical Rough In Inspection VOID 10/03/2024
Ray Cockerham ((253) 841-5585)
Corrections:


Other/Miscellaneous
Outstanding
07/23/2024
1. diffusers at ceiling grid approved

Conditions

Condition Status Category
Building Permit Standard Conditions Open Standard Conditions
Building Division
* Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
Fire Review Conditions Open Standard Conditions
• Comply with 2018 IFC and 2018 IBC • Total coverage required in the city of puyallup • L&I Final required prior to Fire Final • Exit lighting test required, contractor to provide light meter • Separate permits required for Fire Alarm and Fire Sprinkler • RTU’S will be required to be tested for shut down • Smoke and Fire dampeners will be tested with Fire Alarm. Access doors are required for maintenance and visual inspection. • Fire extinguishers required per code • A Knox box is required at the front entry on the exterior of the building if equipped with a Fire Alarm System or Fire Sprinkler System. • PIV must have a Knox lock or approved lock with an extra key provided in Knox box • Existing buildings will need to contact central pierce fire & rescue and update the key in the Knox box • All above items to be completed prior to fire final. Fire final required before building final Schedule your inspection online through the City of Puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email prior to inspection for date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov
Miscellaneous Condition Resolved Prior to Issuance
Engineering Division
A Utility Connection/Repair permit must be issued to install the required sewer sampling tee. Another TI application, PRCTI20221019, is under review for this building with this same condition. Once the the utility permit is issued both can be released. LL
Miscellaneous Condition Resolved Prior to Occupancy
Engineering Division
Occupancy will not be granted until the sewer sampling tee has been installed and a final inspection has been approved on the installation. Another TI application, PRCTI20221019, is under review for this building with this same condition. Once the the sewer sampling tee has been installed and approved both can ask for a final engineering inspection. LL Sewer sampling tee has been installed and approved by Jeff Hill under permit # PRUSR20230614. MR
Engineering Commercial Standard Conditions Open Standard Conditions
Engineering Division
Development Engineering standard commercial conditions: - Occupancy will not be granted until all work associated with the required utility connection/repair permit PRUSR20230614 to install the sewer sampling tee has been completed and approval has been provided. -- A commercial development must have installed a side sewer sampling tee installed in conformance to city standard section 04.03 – side sewer. - The record civil drawings indicate that a reduced pressure backflow assembly has been installed. However if one does not exist on the water service connections an approved backflow prevention assembly must be installed as directed by the Puyallup Municipal Code 14.02.220(3) and conforming to city standard section 03.04 - backflow installation. A reduced pressure backflow assembly (RPBA) is required as directed by the City of Puyallup, - Due to the proximity of this property to a secondary water source (i.e. clarks creek, meeker ditch, etc.) the applicant shall install a reduced pressure backflow assembly per city standards. - Any code requirement that may have been overlooked in this plan review does not imply that the requirements have been waived.

Related Permit & Planning Applications

Reference Number Status Type
PRUSR20230614 Closed Utility Service Repair/PRIVATE PROPERTY ONLY
PRFS20230864 Expired Fire Sprinklers
PRFA20230883 Closed Fire Alarms
PRFA20231139 Closed Fire Alarms
PRFA20231193 Closed Fire Alarms
PRCTI20240469 Closed Commercial - Tenant Improvement/Remodel
PRFS20240702 Permit(s) Issued Fire Sprinklers
PRCTI20250557 Closed Commercial - Tenant Improvement/Remodel
PRSG20250891 Closed Sign/Awning
PRCTI20251104 Ready for Issuance Commercial - Tenant Improvement/Remodel
PRCTI20251201 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRSG20251300 Permit(s) Issued Sign/Awning
PRFA20251359 In Plan Check Fire Alarms

Documents & Images

Date Uploaded File Type Name
03/14/2023 Receipt Receipt for transaction:2023-000404
03/14/2023 Letter Incomplete Application Notice
03/15/2023 Other Burgess Narrative of Scope_Puyallup 1 Redemise
03/15/2023 Letter Incomplete Application Notice
03/16/2023 Letter Incomplete Application Notice
04/21/2023 Letter Permit Review Correction Letter
04/21/2023 Form Building Permit Application 790_202210181748296855 (Flattened)
05/22/2023 Form Puyallup 1-Correction Letter -Response_230519
05/23/2023 Receipt Receipt for transaction:2023-000929
06/07/2023 Plans CONSTRUCTION PLAN SET (Stamped)
06/07/2023 Plans Puyallup 1 Demise_City Correction1 Set_19MAY23 (Stamped)
06/07/2023 Form Puyallup 1 NREC corrections (Stamped)
06/07/2023 Report 2023-03-17 - Puyallup 1 Rooftop HVAC Replacement Structural Eval Letter - KPFF (Stamped)
06/07/2023 Report 23-01_42 Prologis Puyallup 1 HVAC_Structural Calc_ (Stamped)
06/07/2023 Form Plumbing fixture worksheet_202012021825172385 11 (Stamped)
06/07/2023 Map PUYALLUP 1 DEMISE_SITE PLAN_13MAR23 (Stamped)
06/07/2023 Other Prologis Mechanical As-built Set (Stamped)
06/08/2023 Receipt Receipt for transaction:2023-001053
06/08/2023 Permit Permit - Detailed
07/05/2023 Report Inspection Report (Frame Inspection)
07/07/2023 Report Inspection Report (Frame Inspection)
07/10/2023 Report Inspection Report (Frame Inspection)
07/19/2023 Report Inspection Report (Shear Wall Inspection)
08/03/2023 Report Inspection Report (Mechanical Rough In Inspection)
08/14/2023 Report Inspection Report (Shear Wall Inspection)
08/16/2023 Report Inspection Report (Shear Wall Inspection)
08/28/2023 Shear wall engineering
08/28/2023 Report Inspection Report (Shear Wall Inspection)
08/30/2023 Report Inspection Report (Shear Wall Inspection)
09/11/2023 Report Inspection Report (Shear Wall Inspection)
09/14/2023 Report Inspection Report (Shear Wall Inspection)
10/10/2023 Report Inspection Report (Ceiling Grid/T-Bar Inspection)
10/23/2023 Report Inspection Report (Mechanical Rough In Inspection)
10/23/2023 Report Inspection Report (Mechanical Final Inspection)
10/24/2023 Report Inspection Report (Ceiling Grid/T-Bar Inspection)
10/30/2023 Report Inspection Report (Ceiling Grid/T-Bar Inspection)
03/08/2024 Report Inspection Report (Ceiling Grid/T-Bar Inspection)
04/25/2024 Report Inspection Report (Comment Building Div Inspection)
09/09/2024 Report Inspection Report (Building Final Inspection)