Summary

PRFA20241149
Fire Alarms
Closed
BCC PUYALLUP LLC
Addition
ADDITION OF NOTIFICATION APPLIANCES AND FULL DETECTOR COVERAGE INTHE RENOVATED AREA ON BASEMENT LEVEL AS REFLECTED ON THE FLOORPLAN. NEW NOTIFICATION APPLIANCES SHALL BE TIED TO THE EXISTING FACP. - CENTRAL PIERCE FIRE & RESCUE WAREHOUSE
07/19/2024
08/12/2024
03/02/2025
09/03/2024

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
08/12/2024 ALARM PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 08/20/2024 08/09/2024

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $345.00 $345.00 Paid 07/19/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Fire Alarm Cover Inspection VOID 09/03/2024
David Drake ((253) 864-4171)
Piv And Tamper Inspection VOID 09/03/2024
David Drake ((253) 864-4171)

Conditions

Condition Status Department Category Expiration Date Due Date
New Fire Alarm System Conditions Open Standard Conditions
: • Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first. David Drake ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20230098 Closed Commercial - Tenant Improvement/Remodel
PRFA20230119 Closed Fire Alarms
PRFS20230429 Closed Fire Sprinklers
PRCTI20240250 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFS20240914 Closed Fire Sprinklers

Documents & Images

Date Uploaded File Type Name
07/19/2024 Receipt Receipt for transaction:2024-001494
08/12/2024 Plans ALARM PLANS (Stamped)
08/12/2024 Permit Permit - Detailed
08/12/2024 Letter Permit Job Card