CITY OF PUYALLUP PERMITTING PORTAL
Permit Application Status
PRCTI20230098
In order to request inspections, you need to be signed in.
Paid Fees | Amount | Paid | Owing | Date Paid |
---|---|---|---|---|
Fire Review Fee (Commercial Building) | $265.00 | $265.00 | Paid | 03/10/2023 |
Exhaust Vent Fan (Bath) Fee | $28.20 | $28.20 | Paid | 03/10/2023 |
Building Permit Fee | $7,433.75 | $7,433.75 | Paid | 03/10/2023 |
Mechanical Permit Fee | $40.00 | $40.00 | Paid | 03/10/2023 |
Backflow Preventor Fee | $52.00 | $52.00 | Paid | 01/30/2023 |
Plumbing Permit Fee | $40.00 | $40.00 | Paid | 03/10/2023 |
Drinking Fountain, Water Cooler, Ice Machine Fee | $40.25 | $40.25 | Paid | 03/10/2023 |
Water Heater Fee | $13.00 | $13.00 | Paid | 03/10/2023 |
Building Plan Review Fee | $4,831.94 | $4,831.94 | Paid | 01/30/2023 |
Mechanical Plan Review Fee | $44.33 | $44.33 | Paid | 01/30/2023 |
Plumbing Plan Review Fee | $94.41 | $94.41 | Paid | 01/30/2023 |
WA State Building Code Council Fee (Commercial) | $25.00 | $25.00 | Paid | 03/10/2023 |
Resubmittal Fee | $130.00 | $130.00 | Paid | 03/23/2023 |
Outstanding Fees | Amount | Paid | Owing | Date Paid |
No outstanding fees. | ||||
Totals: | $13,037.88 | $13,037.88 | $0.00 |
Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.
$0.00
Inspection | Outcome | Requested | Scheduled | Date Inspected |
---|---|---|---|---|
Plumbing Below Slab Inspection | Partial Pass | 3/22/2023 | 3/22/2023 | 03/22/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Carried Forward
03/22/2023
1 ; provide as built below slab plumbing plans prior to final.
2 ; provide run test as discussed with contractor.
|
||||
Plumbing Below Slab Inspection | Passed w/ Conditions | 3/23/2023 | 3/23/2023 | 03/23/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Outstanding
03/23/2023
1 ; approved pending as built plumbing plans prior to final.
|
||||
Foundation/Rebar Inspection | Partial Pass | 3/29/2023 | 3/29/2023 | 03/29/2023 |
Shannon King ((253) 840-6684) | ||||
Frame Inspection | Not Ready | 3/30/2023 | 3/30/2023 | 03/30/2023 |
Shannon King ((253) 840-6684) | ||||
Energy (Insulation) Inspection | Partial Pass | 3/30/2023 | 3/30/2023 | 03/30/2023 |
Shannon King ((253) 840-6684) | ||||
Frame Inspection | Partial Pass | 4/13/2023 | 4/13/2023 | 04/13/2023 |
Shannon King ((253) 840-6684) | ||||
Energy (Insulation) Inspection | Partial Pass | 4/13/2023 | 4/13/2023 | 04/13/2023 |
Shannon King ((253) 840-6684) | ||||
Cover Inspection/Thrust Blocks Inspection | VOID | 4/13/2023 | 4/13/2023 | 04/13/2023 |
Jason Little ((253) 244-0387) | ||||
Plumbing Rough In Inspection | Not Ready | 4/28/2023 | 4/28/2023 | 04/28/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Other/Miscellaneous
Carried Forward
04/28/2023
1. Canceled on site by contractor
|
||||
Mechanical Rough In Inspection | Not Ready | 4/28/2023 | 4/28/2023 | 04/28/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Other/Miscellaneous
Carried Forward
04/28/2023
.canceled by contractor on site
|
||||
Combination Frame And Rough In Inspection | Partial Pass | 5/1/2023 | 5/1/2023 | 05/01/2023 |
Shannon King ((253) 840-6684) | ||||
Wallboard / Drywall Inspection | Partial Pass | 5/1/2023 | 5/1/2023 | 05/01/2023 |
Shannon King ((253) 840-6684) | ||||
Wallboard / Drywall Inspection | Partial Pass | 5/4/2023 | 5/4/2023 | 05/04/2023 |
Shannon King ((253) 840-6684) | ||||
Comment Building Div Inspection | Partial Pass | 5/8/2023 | 5/8/2023 | 05/08/2023 |
Shannon King ((253) 840-6684) | ||||
Energy (Insulation) Inspection | Partial Pass | 5/8/2023 | 5/8/2023 | 05/08/2023 |
Shannon King ((253) 840-6684) | ||||
Frame Inspection | Partial Pass | 5/9/2023 | 5/9/2023 | 05/09/2023 |
Shannon King ((253) 840-6684) | ||||
Wallboard / Drywall Inspection | Partial Pass | 5/9/2023 | 5/9/2023 | 05/09/2023 |
Shannon King ((253) 840-6684) | ||||
Fire Or Smoke Damper Inspection | Not Ready | 5/9/2023 | 5/10/2023 | 05/10/2023 |
David Drake ((253) 864-4171) | ||||
Energy (Insulation) Inspection | Partial Pass | 5/12/2023 | 5/12/2023 | 05/12/2023 |
Shannon King ((253) 840-6684) | ||||
Frame Inspection | Failed | 5/12/2023 | 5/12/2023 | 05/12/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Carried Forward
05/12/2023
1 ;complete framing of fire/smoke dampers as per install instructions.
|
||||
Wallboard / Drywall Inspection | Not Ready | 5/16/2023 | 5/16/2023 | 05/16/2023 |
Shannon King ((253) 840-6684) | ||||
Combination Frame And Rough In Inspection | Partial Pass | 5/16/2023 | 5/16/2023 | 05/16/2023 |
Shannon King ((253) 840-6684) | ||||
Mechanical Rough In Inspection | Partial Pass | 5/16/2023 | 5/16/2023 | 05/16/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Resolved
05/16/2023
.canceled by contractor on site
|
||||
Wallboard / Drywall Inspection | Partial Pass | 5/17/2023 | 5/17/2023 | 05/17/2023 |
Shannon King ((253) 840-6684) | ||||
Wallboard / Drywall Inspection | Partial Pass | 5/22/2023 | 5/22/2023 | 05/22/2023 |
Shannon King ((253) 840-6684) | ||||
Fire Access Inspection | VOID | 5/24/2023 | 05/24/2023 | |
David Drake ((253) 864-4171) | ||||
Frame Inspection | Not Ready | 5/24/2023 | 5/24/2023 | 05/24/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Resolved
05/24/2023
1 ;complete framing of fire/smoke dampers as per install instructions.
|
||||
Ceiling Grid/T-Bar Inspection | Not Ready | 5/30/2023 | 5/30/2023 | 05/30/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Mechanical Rough In Inspection | Partial Pass | 5/30/2023 | 5/30/2023 | 05/30/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Combination Frame And Rough In Inspection | Partial Pass | 5/31/2023 | 5/31/2023 | 05/31/2023 |
Shannon King ((253) 840-6684) | ||||
Firewall/Firestop Inspection | Failed | 5/31/2023 | 5/31/2023 | 05/31/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Carried Forward
05/31/2023
1 ; complete firestop at penetration of shaftwall as discussed with contractor.
|
||||
Frame Inspection | Partial Pass | 6/1/2023 | 6/1/2023 | 06/01/2023 |
Shannon King ((253) 840-6684) | ||||
Firewall/Firestop Inspection | Failed | 6/1/2023 | 6/1/2023 | 06/01/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Carried Forward
06/01/2023
1 ; complete firestop at penetration of shaftwall as discussed with contractor.
|
||||
Other/Miscellaneous
Carried Forward
06/01/2023
1 ; complete firestop at penetration of shaft wall as discussed with contractor.
|
||||
Frame Inspection | Partial Pass | 6/2/2023 | 6/2/2023 | 06/02/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Firewall/Firestop Inspection | Partial Pass | 6/2/2023 | 6/2/2023 | 06/02/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Other/Miscellaneous
Resolved
06/02/2023
1 ; complete firestop at penetration of shaftwall as discussed with contractor.
|
||||
Other/Miscellaneous
Resolved
06/02/2023
1 ; complete firestop at penetration of shaft wall as discussed with contractor.
|
||||
Wallboard / Drywall Inspection | Partial Pass | 6/5/2023 | 6/5/2023 | 06/05/2023 |
Shannon King ((253) 840-6684) | ||||
Ceiling Grid/T-Bar Inspection | Partial Pass | 6/6/2023 | 6/6/2023 | 06/06/2023 |
Shannon King ((253) 840-6684) | ||||
Firewall/Firestop Inspection | Partial Pass | 6/6/2023 | 6/6/2023 | 06/06/2023 |
Shannon King ((253) 840-6684) | ||||
Firewall/Firestop Inspection | Partial Pass | 6/12/2023 | 6/12/2023 | 06/12/2023 |
Shannon King ((253) 840-6684) | ||||
Wallboard / Drywall Inspection | Partial Pass | 6/12/2023 | 6/12/2023 | 06/12/2023 |
Shannon King ((253) 840-6684) | ||||
Mechanical Rough In Inspection | Failed | 6/12/2023 | 6/12/2023 | 06/12/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Carried Forward
06/12/2023
1 ; complete positive attachment of diffusers to main and cross-tee of ceiling grid.
|
||||
Ceiling Grid/T-Bar Inspection | Failed | 6/12/2023 | 6/12/2023 | 06/12/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Carried Forward
06/12/2023
1 ; complete perimeter tie wires as discussed with ceiling contractor.
2 ; provide min 3 complete turns at all tie wires of lights.
3 ; complete positive attachment of diffusers to main and cross-tee of ceiling grid.
4 ; complete wall angles at smoke/fire dampers. ( complete fire damper labels as discussed with contractor prior to ceiling cover inspection approval.)
6 ; complete marking of firewalls as discussed with contractor.
7 ; inspection at north side of building only.
|
||||
Firewall/Firestop Inspection | Not Ready | 6/13/2023 | 6/13/2023 | 06/13/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Mechanical Rough In Inspection | Failed | 6/13/2023 | 6/13/2023 | 06/13/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Other/Miscellaneous
Carried Forward
06/13/2023
1. complete diffuser attachment as discussed with contractor
|
||||
Ceiling Grid/T-Bar Inspection | Not Ready | 6/13/2023 | 6/13/2023 | 06/13/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Other/Miscellaneous
Carried Forward
06/13/2023
1 ; complete perimeter tie wires as discussed with ceiling contractor.
2 ; provide min 3 complete turns at all tie wires of lights.
3 ; complete positive attachment of diffusers to main and cross-tee of ceiling grid.
4 ; complete wall angles at smoke/fire dampers. ( complete fire damper labels as discussed with contractor prior to ceiling cover inspection approval.)
6 ; complete marking of firewalls as discussed with contractor.
7 ; inspection at north side of building only.
|
||||
Other/Miscellaneous
Carried Forward
06/13/2023
1.complete items from previous list
|
||||
Mechanical Rough In Inspection | Partial Pass | 6/14/2023 | 6/14/2023 | 06/14/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Resolved
06/14/2023
1. complete diffuser attachment as discussed with contractor
|
||||
Ceiling Grid/T-Bar Inspection | Partial Pass | 6/14/2023 | 6/14/2023 | 06/14/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Resolved
06/14/2023
1 ; complete perimeter tie wires as discussed with ceiling contractor.
2 ; provide min 3 complete turns at all tie wires of lights.
3 ; complete positive attachment of diffusers to main and cross-tee of ceiling grid.
4 ; complete wall angles at smoke/fire dampers. ( complete fire damper labels as discussed with contractor prior to ceiling cover inspection approval.)
6 ; complete marking of firewalls as discussed with contractor.
7 ; inspection at north side of building only.
|
||||
Other/Miscellaneous
Resolved
06/14/2023
1.complete items from previous list
|
||||
Exit Lighting Test Inspection | Failed | 6/16/2023 | 6/16/2023 | 06/16/2023 |
David Drake ((253) 864-4171) | ||||
Exit Light Test
Carried Forward
06/16/2023
Add Exit sign NW corner of hallway by stairwell, make visible for North offices. Add emergency lighting Westside of building in hallway that travels North to South at mid point.
|
||||
Firewall/Firestop Inspection | Passed w/ Conditions | 6/16/2023 | 6/16/2023 | 06/16/2023 |
Monty Johnson ((253) 770-3326) | ||||
Other/Miscellaneous
Outstanding
06/16/2023
all walls above grid on north side minus 1 exterior wall that was getting sealed at time of inspection
|
||||
Planning Final Inspection | VOID | 6/15/2023 | 06/20/2023 | |
Nabila Comstock ((253) 770-3361) | ||||
Mechanical Rough In Inspection | Not Ready | 6/16/2023 | 6/16/2023 | 06/21/2023 |
Monty Johnson ((253) 770-3326) | ||||
Other/Miscellaneous
Carried Forward
06/21/2023
1:complete siezmic bracing of main trunks.
|
||||
Ceiling Grid/T-Bar Inspection | Partial Pass | 6/16/2023 | 6/16/2023 | 06/21/2023 |
Monty Johnson ((253) 770-3326) | ||||
Other/Miscellaneous
Carried Forward
06/21/2023
north side grid ok .
|
||||
Fire Final Inspection | Partial Pass | 6/22/2023 | 06/22/2023 | |
Ray Cockerham ((253) 841-5585) | ||||
Fire Final
Carried Forward
06/22/2023
Fire Final Required
TCO for final - resolve fire alarm permit. corrections.
10 days
|
||||
Fire Final Inspection | Failed | 6/20/2023 | 6/21/2023 | 06/22/2023 |
Ray Cockerham ((253) 841-5585) | ||||
Other/Miscellaneous
Resolved
06/21/2023
Fire Alarm test incomplete
|
||||
Building Final Inspection | Partial Pass | 6/22/2023 | 6/22/2023 | 06/22/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Outstanding
06/22/2023
1 ; complete fire caulking of penetrations at rated walls of electrical room and corridor.
2 ; complete occupancy load signage as per City approved plans.
3 ; complete lower strap at hot water heater as discussed with contractor.
4 ; provide accessible signage at restroom 102.
5 ; complete fire caulking of penetrations at rated walls of elevator equipment room.
6 ; complete smoke seal at rated door at elevator equipment rooms.
7 ;complete fire caulking above ceiling at conference room rated walls.
8 ; complete threshold at exterior exit door at n.e. corner of building .
9 ; complete fire caulking of penetrations at rated walls at fire sprinkler room.
10 ; provide accessible toilets 17-19 above finish floor as per City approved plans.
11 ; provide 1/2'' max threshold at accessible shower.
12 ; provide clarification of rear accessible grab bar requirements at shower.
13 ; provide min. 10' separation from air intake of R.T.U.to plumbing vent.
14 ; complete 3 clouds as discussed with contractor.
15 ; provide fire final prior to building final inspection.
16 ; T.C.O. approved for 10 working days from 6/22/2023
|
||||
Mechanical Final Inspection | Failed | 6/22/2023 | 6/22/2023 | 06/22/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Carried Forward
06/22/2023
1; provide min. 10' separation from air intake of R.T.U.to plumbing vent.
|
||||
Plumbing Final Inspection | Failed | 6/22/2023 | 6/22/2023 | 06/22/2023 |
Shannon King ((253) 840-6684) | ||||
Other/Miscellaneous
Carried Forward
06/22/2023
1 ; complete lower strap at hot water heater as discussed with contractor.
2 ; provide accessible toilets 17-19 above finish floor as per City approved plans.
3 ; provide 1/2'' max threshold at accessible shower.
4 ; provide clarification of rear accessible grab bar requirements at shower.
5 ; provide min. 10' separation from air intake of R.T.U.to plumbing vent.
|
||||
Building Final Inspection | Failed | 7/12/2023 | 7/12/2023 | 07/14/2023 |
Ray Cockerham ((253) 841-5585) | ||||
Other/Miscellaneous
Carried Forward
07/14/2023
From previous inspection:
10 ; provide accessible toilets 17-19 above finish floor as per City approved plans.
14 ; complete 3 clouds as discussed with contractor.
16 ; T.C.O. approved for 180 working days from 7/14/2023
Generator installation is not completed. Complete with fire inspection and provide commissioning report for review.
New
Complete accordion door installation (on backorder)
|
||||
Comment Engineering Div Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Footing/Setback Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Slab/Insulation Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Roof Sheathing Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Shear Wall Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Hydronic Piping Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Refrigeration Line Test Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Exhaust Hood Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Light Test For Grease Duct Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Medical Gas Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Hydrostatic Test 200Lbs 2Hrs | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Emergency Radio Test Review Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Plumbing Below Slab Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Other/Miscellaneous
Outstanding
03/22/2023
1 ; provide as built below slab plumbing plans prior to final.
2 ; provide run test as discussed with contractor.
|
||||
Foundation/Rebar Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Energy (Insulation) Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Comment Building Div Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Combination Frame And Rough In Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Frame Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Wallboard / Drywall Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Mechanical Rough In Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Other/Miscellaneous
Outstanding
06/21/2023
1:complete siezmic bracing of main trunks.
|
||||
Ceiling Grid/T-Bar Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) | ||||
Other/Miscellaneous
Outstanding
06/21/2023
north side grid ok .
|
||||
Fire Final Inspection | VOID | 07/05/2024 | ||
Joyce Kennedy ((253) 841-5405) |
Condition | Status | Department | Category | Expiration Date | Due Date |
---|---|---|---|---|---|
Building Permit Standard Conditions | Open | Building Division | Standard Conditions | ||
:
* Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
|
|||||
Fire Review Conditions | Open | Standard Conditions | |||
:
• Comply with 2018 IFC and 2018 IBC
• Total coverage required in the city of puyallup
• L&I Final required prior to Fire Final
• Exit lighting test required, contractor to provide light meter
• Separate permits required for Fire Alarm and Fire Sprinkler
• RTU’S will be required to be tested for shut down
• Smoke and Fire dampeners will be tested with Fire Alarm. Access doors are required for maintenance and visual inspection.
• Fire extinguishers required per code
• Elevators – L&I Final required prior to inspection; Fire Alarm contractor required for inspection.
• A Knox box is required at the front entry on the exterior of the building if equipped with a Fire Alarm System or Fire Sprinkler System.
• PIV must have a Knox lock or approved lock with an extra key provided in Knox box
• Existing buildings will need to contact central pierce fire & rescue and update the key in the Knox box
• All above items to be completed prior to fire final. Fire final required before building final
Schedule your inspection online through the City of Puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email prior to inspection for date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays.
David Drake 253-864-4171 ddrake@puyallupwa.gov
|
|||||
Engineering Commercial Standard Conditions | Open | Engineering Division | Standard Conditions | ||
:
Development Engineering standard commercial conditions:
- A commercial development must have installed a side sewer sampling tee installed in conformance to city standard section 04.03 – side sewer.
- Any code requirement that may have been overlooked in this plan review does not imply that the requirements have been waived.
|
|||||
Miscellaneous Condition | Resolved | Engineering Division | Prior to Occupancy | ||
:
A sewer sampling tee must be installed if one currently does not exit. The applicant was notifed by email on 02/21/2023. LL
After a site visit it was determined that a sampling tee would not be required. See attached email. 03/09/2023 LL
|
Reference Number | Status | Type |
---|---|---|
PRFA20230119 | Closed | Fire Alarms |
PRFS20230429 | Closed | Fire Sprinklers |
PRCTI20240250 | Permit(s) Issued | Commercial - Tenant Improvement/Remodel |
PRFS20240914 | Closed | Fire Sprinklers |
PRFA20241149 | Closed | Fire Alarms |
Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.