CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20241727


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20241727
Fire Alarms
Permit(s) Issued
WRI-URS SOUTH HILL LLC
Alteration/Remodel
Add notification devices for shell space for tenant improvement.
11/06/2024
12/10/2024
12/10/2025

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
12/10/2024 FIRE ALARM PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 12/10/2024 12/10/2024

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $345.00 $345.00 Paid 11/06/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Exterior fire bell required outside fire sprinkler room. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • RTU’S and smoke dampeners will be required to be tested during inspection. RTU’S of 2000cfm or higher are required to be monitored and will required shutdown. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first. David Drake ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20240669 Closed Commercial - Tenant Improvement/Remodel
PRFS20241520 Closed Fire Sprinklers
PRUSR20241577 Closed Utility Service Repair/PRIVATE PROPERTY ONLY
PRFS20241638 Closed Fire Sprinklers
PRUSR20241718 Closed Utility Service Repair/PRIVATE PROPERTY ONLY
PRSG20241748 Closed Sign/Awning
PRFS20241876 Closed Fire Sprinklers

Documents & Images

Date Uploaded File Type Name
11/06/2024 Receipt Receipt for transaction:2024-002320
11/07/2024 Form APPLICATION FORM
12/10/2024 Plans Boot Barn - Equipment Submittal (Flattened)
12/10/2024 Plans FIRE ALARM PLANS (Stamped)
12/10/2024 Permit Permit - Detailed
12/10/2024 Letter Permit Job Card
05/12/2025 Letter Permit Expiration Notice


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.