CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20250627


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20250627
Fire Alarms
Returned for Correction
WESTERN WASHINGTON FAIR ASSOCIATION
New
(111) ALARMS ~ WSF -INTERNATIONAL VILLAGE
05/09/2025

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Failed 06/09/2025 05/14/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $517.50 $517.50 Paid 05/09/2025
Outstanding Fees Amount Paid Owing Date Paid
Resubmittal Fee $180.00 $0.00 $180.00 Not Paid


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$180.00    Add Fees to My Cart

Inspections

There are no inspections for this development permit application, or you are not authorized to view them.

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
1- APPOINTMENT REQUIRED FOR ALL INSPECTIONS 2- PROVIDE PLANS AND PERMIT ON SITE FOR INSPECTION. 3- COMPLETE LABOR AND INDUSTRIES INSPECTIONS PRIOR TO REQUESTING CITY INSPECTION. 4- A REMOTE ANNUCIATOR LOCATED ON THE EXTERIOR OF THE MAIN ENTRANCE IN A WEATHER PROOF HOUSING REQUIRED. 5- EXTERIOR FIRE BELL REQUIRED OUTSIDE FIRE SPRINKLER ROOM. 6- DEVICE MAPS REQUIRED AT THE ANNUNCIATOR AND FIRE ALARM PANEL PRIOR TO CALLING IN FINAL. THE ANNUNCIATOR MAP WILL NEED TO BE WEATHER PROOF. 7- TOTAL COVERAGE IS REQURED; SUBJECT TO FIELD INSPECTION. COMPLY WITH NFPA 72, 2013 8- FIRE ALARM SYSTEM SHALL BE PLACARDED PER NFPA 72. THE UL CERTIFICATE SHALL BE POSTED AT TIME OF FINAL INSPECTION. THE SYSTEM WILL NEED TO BE UL CERTIFIED. 9- A PRE-TEST SHALL BE CONDUCTED AND A PRINT OUT OF THE LOCATION OF THE DEVICE, POINT NUMBER AND DESCRIPTOR SHALL BE FURNISHED TO THE INSPECTOR AT FINAL. 10- FIRE SPRINKLER TAMPER VALVES AND PIV WILL BE REQUIRED TO BE TESTED AT INSPECTION. FIRE SPRINKLER CONTRACTOR TO BE ONSITE. 11- THE CITY OF PUYALLUP ALLOWS ONE FACP PER BUILDING. THE PANEL WILL NEED TO BE LARGE ENOUGH TO HANDLE MULTIPLE TENTANTS IF APPLICABLE.

Related Permit & Planning Applications

Reference Number Status Type
PRCNC20241090 Permit(s) Issued Commercial - New Construction
PRCCP20241189 Permit(s) Issued Civil Construction Permit
PRDE20241420 Closed Demolition
PRHM20241860 Closed Hydraulic Modeling
PRFS20250027 Permit(s) Issued Fire Sprinklers
PRFS20250708 In Plan Check Fire Sprinklers
PLPRE20230120 File Closed Pre-Application
PLPSP20240052 Waiting for Conditions Preliminary Site Plan

Documents & Images

Date Uploaded File Type Name
05/09/2025 Form UL CERTIFICATE
05/09/2025 Plans 1st & 2nd FLOOR PLAN
05/09/2025 Plans SYSTEM CALCS
05/09/2025 Plans ALARM PLANS
05/09/2025 Receipt Receipt for transaction:2025-000911
05/09/2025 Form 0627 APPLICATION
05/16/2025 Letter Permit Review Correction Letter
05/16/2025 Plans 79018-1 WA State Fair International Village - Data Submittal - 05-08-25 (Flattened)


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.