PRFA20260129
Fire Alarms
Permit(s) Issued
CAFARO NORTHWEST PARTNERSHIP
Alteration/Remodel
The project shall include: Tennant improvement to existing fire alarm system at the south hill mall. connect speaker strobes to the existing speaker and strobes circuits located in the tennant space. Existing fire alarm power supply to remain. Connect new SLC devices to existing slc ckt. - PANDORA
02/03/2026
02/19/2026
09/01/2026

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
02/19/2026 FIRE ALARM PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 03/02/2026 02/19/2026

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $132.25 $132.25 Paid 02/03/2026
Outstanding Fees Amount Paid Owing Date Paid
Building Division Fee (Hourly) $0.00 $0.00 Not payable Not Paid


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection VOID 3/5/2026 03/05/2026
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. Inspections are Monday - Thursday, no friday inspections • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72, 2019 • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • A pre-test shall be conducted and a printout of the location of the device, point number and descriptor shall be furnished to the inspector at final. Labeling of all devices above and below ceiling required. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20251416 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFS20260091 Permit(s) Issued Fire Sprinklers

Documents & Images

Date Uploaded File Type Name
02/03/2026 Form APPLICATION FORM
02/03/2026 Plans FIRE ALARM CUT SHEETS
02/03/2026 Receipt Receipt for transaction:2026-000167
02/19/2026 Plans FIRE ALARM PLANS (Stamped)
02/19/2026 Permit Permit - Detailed