CITY OF PUYALLUP PERMITTING PORTAL

Engineering Permit Application Status

PRFUP20220587


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFUP20220587
Franchise Utility Permit
Permit(s) Issued
STEP BY STEP FAMILY SUPPORT CENTER
Utility
PERMIT EXT TO 12/12/2023 - 05098783 - Replace 1 pole 568002-156538. 4x4 cut at base of new pole to install new hand hole on private property. Asplundh to provide tree trimming at P01
03/31/2022
05/17/2022
12/12/2023

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
05/17/2022 105098783 step by step-aud (Stamped)
Review Type Outcome Est. Completion Date Completed
Engineering Review Approved 05/15/2022 05/17/2022
Engineering Review Failed 04/21/2022 04/11/2022

Fees

Paid Fees Amount Paid Owing Date Paid
E Franchise ROW Inspection Fee $130.00 $130.00 Paid 03/31/2022
Franchise Traffic Control Fee $90.00 $90.00 Paid 03/31/2022
ROW Permit Fee $80.00 $80.00 Paid 03/31/2022
Franchise Utility Review Fee $110.00 $110.00 Paid 03/31/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Comment Engineering Div Inspection Pending
Franchise closure pending pole
Outstanding
12/14/2022
Permit closure pending pole removal. Comm is still awaiting transfer as of 12/13/22. Once pulled, portion of crushed rock to be removed and replaced with topsoil. This permit has expired.

Close All Restoration Complete Inspection Pending
Closeout All Work Complete (No Restoration) Inspection Pending
Engineering Final Inspection Pending
Comment Engineering Div Inspection Partial Pass 05/26/2022
Cheryl Trimble ((253) 841-5464)
Comment Engineering Div Inspection Partial Pass 6/27/2022 06/27/2022
Cheryl Trimble ((253) 841-5464)
Comment Engineering Div Inspection Failed 12/13/2022 12/13/2022
Cheryl Trimble ((253) 841-5464)
Franchise closure pending pole
Carried Forward
12/14/2022
Permit closure pending pole removal. Comm is still awaiting transfer as of 12/13/22. Once pulled, portion of crushed rock to be removed and replaced with topsoil. This permit has expired.

Conditions

Condition Status Department Category Expiration Date Due Date
Private Utility Permit Conditions Open Standard Conditions
: APPLICANT/CONTRACTOR REQUIREMENTS: 1. PERMIT AND APPROVED TRAFFIC CONTROL PLAN ARE REQUIRED TO BE AVAILABLE AT JOB SITE. NOT HAVING A PERMIT ONSITE SHALL BE SUBJECT TO TRIPLE PERMIT FEE. 2. THE CITY SHALL BE NOTIFIED 24-48 HOURS PRIOR TO JOB START 3. THE CITY SHALL BE NOTIFIED WHEN ALL WORK AND RESTORATION IS COMPETE AND READY FOR FINAL INSPECTION. PRIOR TO RESTORATION, COORDINATE WITH AN INSPECTOR. *** SITE SPECIFIC CONDITIONS *** ** Guy wire location will not change per the applicant ** GENERAL CONDITIONS: 1. Follow approved Traffic Control Plan (TCP) 2. Follow allowed work hours Monday through Friday 9am-3pm 3. If a lane will be closed, call Comm Center on day of closure prior to work start at 253-841-5431. 4. Spotter must be available to assist with pedestrians if needed. 5. To schedule inspection, go to: Secure.cityofpuyallup.org and select appropriate code. 6. Please utilize traffic control information below for TCP: A. Distance between cones equals speed limit in unit feet. B. Taper length equals width of offset times speed limit squared divided by 60. L = WS² /60 - W= lane width S = speed limit C. Sign spacing shall be 100 feet when speed limit is 30 MPH or less D. Sign spacing shall be 350 feet when speed limit is greater than 30 MPH E. Distance between signs is mandatory unless field conditions determine otherwise. 7. Do not open cut without prior approval. 8. Do not park vehicles on city sidewalk. Curb, gutter or sidewalk damaged shall be replaced. Inspection time performed during a regular 8-hour day Monday through Friday 7:00 am - 5:00 pm is included in the permit fee. Inspection time performed outside of those hours are charged to the permit holder at a rate of $130 per hour with a three-hour minimum. INDEMNIFICATION / HOLD HARMLESS: The Permittee shall defend, indemnify and hold the Public Entity, its officers, officials, employees and volunteers harmless from any and all claims, injuries, damages, losses or suits including attorney fees, arising out of or in connection with activities or operations performed by the Permittee or on the Permittee's behalf out of issuance of this Permit, except for injuries and damages caused by the sole negligence of the Public Entity. However, should a court of competent jurisdiction determine that RCW 4.24.115 applies to this Permit, then the Permittee agrees to defend, indemnify and hold the Public Entity, its officers, officials, employees and volunteers harmless to the maximum extent permitted thereunder. It is further specifically and expressly understood that the indemnification provided herein constitutes the Permittee's waiver of immunity under Industrial Insurance, Title 51 RCW, solely for the purposes of this indemnification. This waiver has been mutually negotiated by the parties. The provisions of this section shall survive the expiration or termination of this Agreement.
Pole Placement Open Development & Permitting Services Standard Conditions
: Where a curb exists, the lateral offset for all vertical obstructions shall be a minimum of 1.5' from the face of the curb to the face of the vertical obstruction and a minimum of 3' at intersections. Where no curb exists, the lateral offset for all vertical obstructions shall be a minimum of 4' measured from the face of the obstruction to the edge of pavement.

Related Permit & Planning Applications

There are no related items for this engineering permit application.

Documents & Images

Date Uploaded File Type Name
05/17/2022 Plans PUYALLUP TCP (Stamped)
05/17/2022 Plans 105098783 step by step-aud (Stamped)
04/12/2022 Form Puyallup_105098783 (Flattened)
03/31/2022 Receipt Receipt for transaction:2022-000606
04/12/2022 Letter Permit Review Comment Notice
05/17/2022 Permit Permit - Detailed
12/14/2022 Report Inspection Report (Comment Engineering Div Inspection)
05/09/2023 Letter Permit Expiration Notice