CITY OF PUYALLUP PERMITTING PORTAL

Engineering Permit Application Status

PRFUP20221126


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFUP20221126
Franchise Utility Permit
Closed
T & L REMODELING LLC
Utility
887037641 - IFS to provide traffic control for PSE to operate gas valves located on intersection of Shaw Rd. Previous attempt to operate valve failed (see permit 20220485 order #887037402)Valve is located 12' N 23RD AVE SE & 42' W CL SHAW RD Approx 30 min to 1 hour / no cuts in right of way. FINAL EXTENSION TO 3/2/23 TO COMPLETE RESTORATION CT DUE TO WEATHER DELAY, FINAL EXTENSION TO 4/27/23 CT
07/18/2022
08/02/2022
09/11/2023
03/15/2023

Locations

Reviews

Documents Returned For Corrections

Review Type Outcome Est. Completion Date Completed
Engineering Review Approved 08/08/2022 08/01/2022

Fees

Paid Fees Amount Paid Owing Date Paid
E Franchise ROW Inspection Fee $130.00 $130.00 Paid 07/18/2022
Franchise Traffic Control Fee $90.00 $90.00 Paid 07/18/2022
ROW Permit Fee $80.00 $80.00 Paid 07/18/2022
Franchise Utility Review Fee $110.00 $110.00 Paid 07/18/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Comment Engineering Div Inspection Partial Pass 9/27/2022 09/28/2022
Cheryl Trimble ((253) 290-9834)
Comment Engineering Div Inspection Failed 1/24/2023 01/24/2023
Cheryl Trimble ((253) 290-9834)
Closeout All Work Complete (No Restoration) Inspection VOID 02/01/2023
Cheryl Trimble ((253) 290-9834)
Close All Restoration Complete Inspection Not Ready 2/23/2023 02/23/2023
Cheryl Trimble ((253) 290-9834)
Comment Engineering Div Inspection VOID 03/15/2023
Cheryl Trimble ((253) 290-9834)

Conditions

Condition Status Department Category Expiration Date Due Date
Private Utility Permit Conditions Open Standard Conditions
: Development Engineering standard franchise utility conditions: Applicant must provide 48hr. notification to residents within 300 feet of the work area either via door hanger, message board or signs posted visibly along the right-of-way. SITE SPECIFIC CONDITIONS: **Approved hours of Obstruction\Closure Allowed Monday - Thursday10 A.M. - 12 P.M. THE ROAD MUST BE FULLY OPENED BY NOON, NO EXCEPTIONS** ** When shifting traffic into a turn lane the use of double cones is required. Device spacing 1/2 distance for opposingtraffic ** Flaggers must remain in radio contact at all times Applicant/Contractor Responsibility: 1. The issued permit and traffic control plan(s) are always required to be available at the job site. The applicant shall be subject to a triple permit fee for failing to have a valid permit on site. 2. The applicant/contractor shall notify the City 24-48 hours prior to starting work by requesting an inspection through the CityView portal. Weekend and night work require a minimum of 48 business hours’ advanced coordination with a City inspector. 3. The applicant/contractor shall notify the City prior to site restoration, immediately after all work and restoration are complete, and when the site is ready for final inspection. The applicant/contractor shall request a final inspection through the CityView portal prior to the permit expiration date. General Conditions: 1. Comply with all permit conditions and the Traffic Control Plans (TCP) issued by the City. 2. Follow the allowed work hours as listed on the issued permit or on each page of the TCP. 3. If a travel lane will be closed, the applicant/contractor shall call the Communications Center at 253-287-4456 prior to starting work on day of closure and again once the lane is reopened. 4. Spotter must be available to assist with pedestrians if needed. 5. Request all inspections through the CityView portal on the City website. 6. Please utilize the traffic control standards below in addition to the TCP: - Traffic control devices shall be 28-inch retro-reflective cones. - Taper length equals width of offset times speed limit squared divided by 60. - Sign spacing shall be 100 feet when speed limit is 30 mph or less. - Sign spacing shall be 350 feet when speed limit is greater than 30 mph. - Distance between cones equals speed limit in unit-feet. - Distance between signs is mandatory unless field conditions determine otherwise. - Travel lane width must be a minimum of 11 feet at all times. - Any and all flaggers and spotters shall remain in radio contact at all times. 7. Open cut is not permitted without prior approval from the City. 8. Do not park vehicles on City sidewalk. Any public curb, gutter, or sidewalk broken now or during construction shall be removed and replaced per City Standards. 9. Inspections performed during a regular 8-hour day Monday through Friday 7:00 am - 5:00 pm is included in the permit fee. Inspection time performed outside of these hours are charged to the permit holder at a rate of $130.00 per hour with a three-hour minimum. 10. The applicant shall comply with Puyallup Municipal Code Chapter 11.05 while working in the public right-of-way. Indemnification / Hold Harmless: The Permittee shall defend, indemnify and hold the Public Entity, its officers, officials, employees and volunteers harmless from any and all claims, injuries, damages, losses or suits including attorney fees, arising out of or in connection with activities or operations performed by the Permittee or on the Permittee's behalf out of issuance of this Permit, except for injuries and damages caused by the sole negligence of the Public Entity. However, should a court of competent jurisdiction determine that RCW 4.24.115 applies to this Permit, then the Permittee agrees to defend, indemnify and hold the Public Entity, its officers, officials, employees and volunteers harmless to the maximum extent permitted thereunder. It is further specifically and expressly understood that the indemnification provided herein constitutes the Permittee's waiver of immunity under Industrial Insurance, Title 51 RCW, solely for the purposes of this indemnification. This waiver has been mutually negotiated by the parties. The provisions of this section shall survive the expiration or termination of this Agreement.
Police Department Traffic Control Open Development & Permitting Services Standard Conditions
: For approved Traffic Control Plans that necessitate the use of police officer assistance, Puyallup police officers will be utilized. Contact Tamara Ferrin at 253-841-5436 or via email at tame@puyallupwa.gov to coordinate. 24 hrs advanced notice is required for coordination/scheduling purposes.
Night Work Conditions Open Development & Permitting Services Standard Conditions
: Night work requirements: - Applicant must provide 48 hour notification to residents within 300 feet of the work area either by door hanger, message board or signs posted visibly along the right-of-way. - Work allowed sunday night through thursday night only between the hours of 9 PM and 5 AM. - 48-hour advance notice is required for coordination/scheduling. Call the engineering inspection message line: dial 253-435-3650.
Night Traffic Control Overtime Inspection Fee Open Development & Permitting Services Standard Conditions
: Night work inspection fees: - Whenever work is progressing within the city, inspectors are required to be available for inspection. Therefore, work beyond a regular 8 hour day also needs inspected. - If your project is the only one operating at that time, you will be required to pay for the inspector to be there full time (3 hour minimum call out time). Whenever possible, the city will distribute fees among other projects working at the same time.

Related Permit & Planning Applications

There are no related items for this engineering permit application.

Documents & Images

Date Uploaded File Type Name
08/01/2022 Plans TCP0 11865042 23rd Av SE & Shaw Av E Puyallup, WA (Stamped)
08/01/2022 Plans PLAT 887037641 (Stamped)
08/01/2022 Plans site plan 887037641 (Stamped)
08/01/2022 Form Puyallup_887037642 (Flattened)
07/18/2022 Receipt Receipt for transaction:2022-001380
08/02/2022 Permit Permit - Detailed
08/02/2022 Letter Permit Job Card
08/06/2022 Plans PRFUP20221126 REVISED TCP - NIGHT WORK


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.