CITY OF PUYALLUP PERMITTING PORTAL
Permit Application Status
PRCTI20230304
Paid Fees | Amount | Paid | Owing | Date Paid |
---|---|---|---|---|
Fire Review Fee (Commercial Building) | $265.00 | $265.00 | Paid | 07/03/2023 |
Exhaust Vent Fan (Bath) Fee | $42.30 | $42.30 | Paid | 07/03/2023 |
Gas Piping (Mechanical) Fee | $6.30 | $6.30 | Paid | 03/12/2023 |
Mechanical Duct Work Fee | $14.10 | $14.10 | Paid | 07/03/2023 |
Building Permit Fee | $2,225.75 | $2,225.75 | Paid | 07/03/2023 |
Mechanical Permit Fee | $40.00 | $40.00 | Paid | 07/03/2023 |
Plumbing Permit Fee | $40.00 | $40.00 | Paid | 07/03/2023 |
Water Heater Fee | $13.00 | $13.00 | Paid | 07/03/2023 |
Building Plan Review Fee | $1,446.74 | $1,446.74 | Paid | 03/12/2023 |
Mechanical Plan Review Fee | $66.76 | $66.76 | Paid | 03/12/2023 |
Plumbing Plan Review Fee | $34.45 | $34.45 | Paid | 03/12/2023 |
WA State Building Code Council Fee (Commercial) | $25.00 | $25.00 | Paid | 07/03/2023 |
Resubmittal Fee | $180.00 | $180.00 | Paid | 05/04/2023 |
Resubmittal Fee | $180.00 | $180.00 | Paid | 06/26/2023 |
Boilers & Compressors/Heat Pump (1,000,001 - 1,750,000 BTU or 30-50 HP) Fee | $73.30 | $73.30 | Paid | 02/13/2024 |
Resubmittal Fee | $180.00 | $180.00 | Paid | 02/13/2024 |
Outstanding Fees | Amount | Paid | Owing | Date Paid |
No outstanding fees. | ||||
Totals: | $4,832.70 | $4,832.70 | $0.00 |
Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.
$0.00
Inspection | Outcome | Requested | Scheduled | Date Inspected |
---|---|---|---|---|
Frame Inspection | Not Ready | 7/12/2023 | 7/12/2023 | 07/15/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
07/15/2023
1. provide header at new exterior door .
2.provide engineering for stud repair at bearing wall as discussed with contractor
3. provide min threshold ht at door to landings interior and exterior as discussed with contractor
4. tenant in back space needs to meet with city to obtain occupancy
|
||||
Comment Building Div Inspection | Not Ready | 8/16/2023 | 8/16/2023 | 08/16/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
08/16/2023
1. discussed inspections needed for cover
|
||||
Plumbing Rough In Inspection | Partial Pass | 8/17/2023 | 8/17/2023 | 08/17/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
08/17/2023
1. DWV and supply approved
|
||||
Mechanical Rough In Inspection | Partial Pass | 8/17/2023 | 8/17/2023 | 08/17/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
08/17/2023
1. gas line approved 15 psi
|
||||
Frame Inspection | Partial Pass | 8/28/2023 | 8/28/2023 | 08/28/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
08/28/2023
1. provide header at new exterior door .
2.provide engineering for stud repair at bearing wall as discussed with contractor
3. provide min threshold ht at door to landings interior and exterior as discussed with contractor
4. tenant in back space needs to meet with city to obtain occupancy
|
||||
Other/Miscellaneous
Carried Forward
08/28/2023
1. header at exterior door approved
2.stud repair at exterior wall approved
3. ok to insulate
|
||||
Combination Frame And Rough In Inspection | Not Ready | 8/28/2023 | 8/28/2023 | 08/28/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
08/28/2023
1. this was a comment inspection discussed requirements for a framing inspection
|
||||
Shear Wall Inspection | Partial Pass | 8/31/2023 | 8/31/2023 | 08/31/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Energy (Insulation) Inspection | Partial Pass | 8/31/2023 | 8/31/2023 | 08/31/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Cover Inspection/Thrust Blocks Inspection | VOID | 9/5/2023 | 9/5/2023 | 09/05/2023 |
Michael Rosenau ((253) 344-6753) | ||||
Firewall/Firestop Inspection | Partial Pass | 9/5/2023 | 9/5/2023 | 09/05/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Exhaust/Vent Fans Inspection | Partial Pass | 9/5/2023 | 9/5/2023 | 09/05/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Combination Frame And Rough In Inspection | Partial Pass | 9/7/2023 | 9/7/2023 | 09/07/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Resolved
09/07/2023
1. this was a comment inspection discussed requirements for a framing inspection
|
||||
Slab/Insulation Inspection | Partial Pass | 9/13/2023 | 9/13/2023 | 09/14/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Wallboard / Drywall Inspection | Passed | 9/26/2023 | 9/26/2023 | 09/26/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Slab/Insulation Inspection | Passed | 10/13/2023 | 10/13/2023 | 10/13/2023 |
Shannon King ((253) 840-6684) | ||||
Comment Building Div Inspection | Not Ready | 12/19/2023 | 12/19/2023 | 12/19/2023 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
12/19/2023
1. discussed inspections needed for cover
|
||||
Other/Miscellaneous
Carried Forward
12/19/2023
1.discussed building final requirements
|
||||
Exit Lighting Test Inspection | Not Ready | 1/4/2024 | 1/4/2024 | 01/04/2024 |
David Drake ((253) 864-4171) | ||||
Corrections:
Exit Light Test
Carried Forward
01/04/2024
Did not test, explained how testing works. Ray, Kevin and I discussed the following.
Bathroom ADA requirements
Kitchen area ADA requirements not on plans
Exiting
Garages can not be used as garages
Items that are onsite and not on plans
Possible tenants and requirements
|
||||
Ceiling Grid/T-Bar Inspection | Not Ready | 1/4/2024 | 1/4/2024 | 01/04/2024 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
01/04/2024
1. complete all ceiling requirements as discussed with contractor
2. not ready
|
||||
Plumbing Final Inspection | Not Ready | 1/4/2024 | 1/4/2024 | 01/04/2024 |
Kevin Spruell ((253) 841-5590) | ||||
Building Final Inspection | Not Ready | 2/9/2024 | 2/9/2024 | 02/09/2024 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
02/09/2024
1. provide engineering, planning,fire and electrical final approval at time of next inspection
2. submit mechanical revision to the city
3. provide signage at bathrooms
4.seal up vapor barrier in ceilings multiple areas
5.complete perimeter wires at ceiling
6.complete birc clips at ceiling
7.complete insulation at hot water lines in MECH room
8.provide correct lock at front door
9.provide signage at front door
10. provide table in lobby that meets accessibility requirements
11. remove old MECH thru roof in electrical room
12.provide copy of backflow cert at time of next inspection
13. provide ladder to inspect roof at time of next inspection
14. NOT A COMPLETE LIST
|
||||
Engineering Final Inspection | Passed | 2/12/2024 | 2/12/2024 | 02/12/2024 |
Michael Rosenau ((253) 344-6753) | ||||
Planning Final Inspection | VOID | 2/12/2024 | 02/12/2024 | |
Chris Beale ((253) 841-5418) | ||||
Mechanical Final Inspection | Not Ready | 2/12/2024 | 2/12/2024 | 02/12/2024 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Carried Forward
02/12/2024
1. cancelled by contractor
|
||||
Ceiling Grid/T-Bar Inspection | Passed | 2/14/2024 | 2/14/2024 | 02/14/2024 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Resolved
02/14/2024
1. complete all ceiling requirements as discussed with contractor
2. not ready
|
||||
Hydrostatic Test 200Lbs 2Hrs | VOID | 02/21/2024 | ||
David Drake ((253) 864-4171) | ||||
Emergency Radio Test Review Inspection | VOID | 02/21/2024 | ||
David Drake ((253) 864-4171) | ||||
Exit Lighting Test Inspection | Passed | 2/21/2024 | 02/21/2024 | |
David Drake ((253) 864-4171) | ||||
Corrections:
Exit Light Test
Resolved
02/21/2024
Did not test, explained how testing works. Ray, Kevin and I discussed the following.
Bathroom ADA requirements
Kitchen area ADA requirements not on plans
Exiting
Garages can not be used as garages
Items that are onsite and not on plans
Possible tenants and requirements
|
||||
Fire Final Inspection | Passed | 2/21/2024 | 2/21/2024 | 02/21/2024 |
David Drake ((253) 864-4171) | ||||
Plumbing Final Inspection | Passed w/ Conditions | 2/26/2024 | 2/26/2024 | 02/26/2024 |
Kevin Spruell ((253) 841-5590) | ||||
Mechanical Final Inspection | Not Ready | 2/26/2024 | 2/26/2024 | 02/26/2024 |
Kevin Spruell ((253) 841-5590) | ||||
Corrections:
Other/Miscellaneous
Resolved
02/26/2024
1. cancelled by contractor
|
||||
Other/Miscellaneous
Carried Forward
02/26/2024
1. provide install instruction for MECH equipment on sit at time of next inspection as discussed with john
|
||||
Building Final Inspection | Passed | 2/28/2024 | 2/28/2024 | 02/28/2024 |
Ray Cockerham ((253) 841-5585) | ||||
Corrections:
Other/Miscellaneous
Resolved
02/28/2024
1. provide engineering, planning,fire and electrical final approval at time of next inspection
2. submit mechanical revision to the city
3. provide signage at bathrooms
4.seal up vapor barrier in ceilings multiple areas
5.complete perimeter wires at ceiling
6.complete birc clips at ceiling
7.complete insulation at hot water lines in MECH room
8.provide correct lock at front door
9.provide signage at front door
10. provide table in lobby that meets accessibility requirements
11. remove old MECH thru roof in electrical room
12.provide copy of backflow cert at time of next inspection
13. provide ladder to inspect roof at time of next inspection
14. NOT A COMPLETE LIST
|
||||
Plumbing Rough In Inspection | Partial Pass | 03/19/2024 | ||
Ray Cockerham ((253) 841-5585) | ||||
Corrections:
Other/Miscellaneous
Resolved
03/19/2024
1. DWV and supply approved
|
||||
Mechanical Rough In Inspection | Partial Pass | 03/19/2024 | ||
Ray Cockerham ((253) 841-5585) | ||||
Corrections:
Other/Miscellaneous
Resolved
03/19/2024
1. gas line approved 15 psi
|
||||
Frame Inspection | Passed | 03/19/2024 | ||
Ray Cockerham ((253) 841-5585) | ||||
Corrections:
Other/Miscellaneous
Resolved
03/19/2024
1. provide header at new exterior door .
2.provide engineering for stud repair at bearing wall as discussed with contractor
3. provide min threshold ht at door to landings interior and exterior as discussed with contractor
4. tenant in back space needs to meet with city to obtain occupancy
|
||||
Other/Miscellaneous
Resolved
03/19/2024
1. header at exterior door approved
2.stud repair at exterior wall approved
3. ok to insulate
|
||||
Comment Building Div Inspection | Not Ready | 03/19/2024 | ||
Ray Cockerham ((253) 841-5585) | ||||
Corrections:
Other/Miscellaneous
Resolved
12/19/2023
1. discussed inspections needed for cover
|
||||
Other/Miscellaneous
Resolved
12/19/2023
1.discussed building final requirements
|
||||
Plumbing Rough In Inspection | Partial Pass | 03/19/2024 | ||
Ray Cockerham ((253) 841-5585) | ||||
Mechanical Final Inspection | Passed | 03/19/2024 | ||
Ray Cockerham ((253) 841-5585) | ||||
Corrections:
Other/Miscellaneous
Resolved
03/19/2024
1. provide install instruction for MECH equipment on sit at time of next inspection as discussed with john
|
Condition | Status | Category |
---|---|---|
Building Permit Standard Conditions | Open | Standard Conditions |
Building Division
* Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
|
||
Fire Review Conditions | Open | Standard Conditions |
1. INSTALL ADDRESS NUMBERS PER THE FOLLOWING DISTANCES:0-50FOOT SETBACK FROM STREET NUMBERS SHALL BE 6 INCHES IN HEIGHT; 51-100 FEET 12 INCHES IN HEIGHT. ALL NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDITIONAL NUMBERS MAY BE NEEDED AT DRIVEWAY ENTRANCE IF BUILDING NUMBERS ARE NOT VISIBLE FROM THE STREET. REAR DOORS OF SUITES OR UNITS SHALL ALSO BE LABELED WITH MINIMUM 4 INCH NUMBERS.
2. FIRE HYDRANTS REQUIRED FOR CONSTRUCTION AND FIRE DEPARTMENT ACCESS SHALL BE INSTALLED AND APPROVED BY THE FIRE CODE OFFICIAL PRIOR TO THE STORAGE OR INSTALLATION OF ANY COMBUSTIBLE FRAMING MATERIAL. ACCESS ROADWAY SURFACES SHALL BE DESIGNED TO CITY STANDARDS AND BE DESIGNED TO MAINTAIN THE IMPOSED LOADS OF A 80,000 POUND FIRE APPARATUS. ASPHALT TREATED BASE, ASPHALT OR CONCRETE PAVEMENT CAN BE USED TO PROVIDE THE REQUIRED ALL-WEATHER DRIVING SURFACE.
3. ANY REQUIRED FIRE LANE MARKINGS SHALL BE INSTALLED PRIOR TO FINAL INSPECTION AND PER CITY ORDINANCE.
4. KNOX BOXES, WHEN REQUIRED, SHALL BE INSTALLED USUALLY TO THE RIGHT OF THE MAIN FRONT DOOR AND NO HIGHER THAN 6 FEET OFF OF THE GROUND. ONLY HINGED KNOX BOXES SHALL BE USED. KNOX BOXES AND KEY SWITCHES CAN BE ORDERED ONLINE AT THE "KNOX COMPANY"
5. FIRE EXTINGUISHERS WILL BE REQUIRED PER CHAPTER 9 OF THE INTERNATIONAL FIRE CODE. GENERALLY, 1 FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A 10BC SHALL BE INSTALLED PER EVERY 3,000 SQUARE FEET OF FLOOR AREA. THE LOCATION OF THE FIRE EXTINGUISHERS SHALL BE NEAR THE EXIT DOORS AND TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. ADDITIONAL SIGNAGE MAY BE NECESSARY TO INDICATE THE FIRE EXTINGUISHER LOCATION.
|
||
Engineering Commercial Standard Conditions | Open | Standard Conditions |
Engineering Division
Development Engineering standard commercial conditions:
** Prior to STARTING the applicant shall request an erosion and sediment control inspection using the CityView permit portal at least 48 hours in advance of job start **
- Stormwater control of roof downspouts required. Attached to the site plan is a typical infiltration system you may choose to follow.
- All commercial development, multi-family, mixed use facility, or irrigation systems water service connections must have installed an approved backflow prevention assembly installed as directed by the Puyallup Municipal Code 14.02.220(3) and conforming to city standard section 03.04 - backflow installation. A double detector check valve assembly (DDCVA) is required or A reduced pressure backflow assembly (RPBA) is required as directed by the City of Puyallup, Fruitland Mutual Water Company, Tacoma City Water or Valley Water District.
- A commercial development must have installed a side sewer sampling tee installed in conformance to city standard section 04.03 – side sewer.
- The builder/owner shall be responsible for keeping the existing right-of-way free of debris and dirt. Any violation of PMC chapter 21.14 pertaining to clearing, filling and grading, erosion and sediment control, and storm water discharges shall be prosecuted to the fullest extent of the law.
- Any addition/expansion to the footprint of the building including decks and porches not originally shown on the approved set of plans must obtain proper permits prior to construction.
- Any code requirement that may have been overlooked in this plan review does not imply that the requirements have been waived.
|
||
Side Sewer Sample Tee | Resolved | Prior to Completion |
Engineering Division
A side sewer sampling connection is required to be installed on the commercial sanitary side sewer service in accordance with City policy ENG 21-03. The site plan shall depict the location and connection of the new or existing sampling connection as per City Standard Detail 04.03.04.
See utility connection permit PRSC20230465. [Yianni Charitou @ 06/22/2023 8:57 AM]
|
There are no related items for this permit application.
Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.