CITY OF PUYALLUP PERMITTING PORTAL

Development Permit Application Status

PRFA20240566


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRFA20240566
Fire Alarms
Permit(s) Issued
CAFARO NORTHWEST PARTNERSHIP
New
NEW CONSTRUCTION OF A FULLY SPRINKLED (5) STORY WOOD FRAMED HOTEL. THE BUILDING WILL BE PROVIDED WITH A FULLY ADDRESSABLE FIRE ALARM SYSTEM WITH A REMOTE ANNUNICATOR LOCATED AT THE FRONT DESK. THE FIRE ALARM SYSTEM WILL PROVIDE TOTAL-COVERAGE DETECTION AS DEFINED IN 2019 NFPA-72 (17.5.3.1) AND PER CITY OF PUYALLUP's REQUIREMENTS. THE FIRE ALARM SYSTEM WILL BE INTERFACED WITH THE (5) STOP ELEVATOR TO PROVIDE PHASE 1 ELEVATOR RECALL. THE FIRE ALARM SYSTEM SHALL MONITOR ALL FIRE ALARM INITIATING DEVICES, THE ERRCS / DAS SYSTEM (IF INSTALLED), ALL FIRE SPRINKLER FLOW DEVICES, AND FIRE SPRINKLER SUPERVISORY DEVICES. AUDIBLE AND VISIBLE OCCUPANT NOTIFICATION WILL BE PROVIDED THROUGHOUT ALL COMMON AREAS. TOTAL COVERAGE SMOKE DETECTION WILL BE PROVIDED THROUGHOUT THE BUILDING, INCLUDING ABOVE AND BELOW ALL SUSPENDED CEILINGS. SMOKE DETECTORS WITH 520Hz LOW FREQUENCY SOUNDER BASES WILL BE INSTALLED IN ALL HOTEL GUESTROOMS. FIRE ALARM VISIBLE OCCUPANT NOTIFICATION DEVICES SHALL BE PROVIDED IN GUESTROOMS WITH COMMUNICATION FEATURES PER ADAS 224.4 AND ACTIVATED BY THE ASSOCIATED GUESTROOM SMOKE DETECTORS AND/OR THE BUILDINGS FIRE ALARM SYSTEM. ACTIVATION OF THE GUESTROOM SMOKE DETECTORS WILL BE A LOCAL ONLY SUPERVISORY SIGNAL; IT WILL NOT DISPATCH THE FIRE DEPARTMENT. ACTIVATION OF THE FIRE ALARM SYSTEM SHALL ACTIVATE THE OUTDOOR HORN/STROBE, ALL AUDIBLE / VISUAL OCCUPANT NOTIFICATION DEVICES, ALL 520Hz LOW-FREQUENCY SMOKE DETECTOR SOUNDER BASES IN GUESTROOMS, RELEASE MAGNETICALLY HELD FIRE DOORS, AND CLOSE FIRE/SMOKE DAMPERS IN RATED WALLS. - HOMEWOOD SUITES
04/04/2024
05/03/2024
10/30/2024

Locations

Property
6021590090

Address
3601 9TH ST SW, PUYALLUP, WA 98373

6021010051
3500 S. MERIDIAN , PUYALLUP WA 98373

Reviews

Documents Returned For Corrections

Date Returned Name
05/03/2024 FIRE ALARM PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 05/02/2024 05/02/2024

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $797.50 $797.50 Paid 04/04/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Department Category Expiration Date Due Date
New Fire Alarm System Conditions Open Standard Conditions
: • Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Exterior fire bell required outside fire sprinkler room. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first. David Drake ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
E-20-0070 Issued Civil Construction Permit
B-20-0180 Permit(s) Issued Commercial - New Construction
E-20-0283 Closed Alternative Methods / Materials Request
PRDE20220405 Closed Demolition
PRFS20240423 Permit(s) Issued Fire Sprinklers
PRCWSA20240533 Closed Certificate of Water/Sewer Availability
PRCCP20240922 In Plan Check Civil Construction Permit

Documents & Images

Date Uploaded File Type Name
04/04/2024 Plans SUBMITTAL DOCUMENTS
04/04/2024 Plans SYSTEM CALCS
05/03/2024 Plans FIRE ALARM PLANS (Stamped)
04/04/2024 Receipt Receipt for transaction:2024-000657
05/08/2024 Permit Permit - Detailed
05/08/2024 Letter Permit Job Card


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.