CITY OF PUYALLUP PERMITTING PORTAL
Development Permit Application Status
PRFA20240566
Paid Fees | Amount | Paid | Owing | Date Paid |
---|---|---|---|---|
Fire Alarm Systems (New) Fee | $797.50 | $797.50 | Paid | 04/04/2024 |
Outstanding Fees | Amount | Paid | Owing | Date Paid |
No outstanding fees. | ||||
Totals: | $797.50 | $797.50 | $0.00 |
Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.
$0.00
Inspection | Outcome | Requested | Scheduled | Date Inspected |
---|---|---|---|---|
Erosion And Sediment Inspection | Stop Work | 11/22/2024 | ||
Jeff Hill ((253) 204-5633) | ||||
Erosion And Sediment Inspection | Passed | 12/03/2024 | ||
Jeff Hill ((253) 204-5633) | ||||
Piv And Tamper Inspection | Not Ready | 7/8/2025 | 7/8/2025 | 07/08/2025 |
David Drake ((253) 864-4171) | ||||
Fire Alarm Test Inspection | Not Ready | 7/8/2025 | 7/8/2025 | 07/08/2025 |
David Drake ((253) 864-4171) | ||||
Piv And Tamper Inspection | Passed | 07/22/2025 | ||
David Drake ((253) 864-4171) | ||||
Fire Alarm Test Inspection | Passed | 07/22/2025 | ||
David Drake ((253) 864-4171) | ||||
Fire Alarm Final Inspection | Passed | 7/22/2025 | 7/22/2025 | 07/22/2025 |
David Drake ((253) 864-4171) | ||||
Fire Alarm Cover Inspection | VOID | 07/23/2025 | ||
David Drake ((253) 864-4171) |
Condition | Status | Category |
---|---|---|
New Fire Alarm System Conditions | Open | Standard Conditions |
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling.
• Provide plans and permit on site for inspection.
• Complete labor and industries inspections prior to requesting city inspection.
• Exterior fire bell required outside fire sprinkler room.
• Above ceiling detection is required.
• Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof.
• Total coverage is required, subject to field inspection. Comply with NFPA 72.
• Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified.
• Pre-test shall be conducted with a printout for inspector at time of inspection.
• Labeling of all devices above and below ceiling required.
• Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite.
• RTU’S and smoke dampeners will be required to be tested during inspection.
• The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable.
• Due to unforeseeable construction design, all device locations to be field verified for compliance.
Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first.
David Drake ddrake@puyallupwa.gov
|
||
Fire Review Conditions | Resolved | Standard Conditions |
Development & Permitting Services
THE BUILDING WILL BE PROVIDED WITH A FULLY ADDRESSABLE FIRE ALARM SYSTEM WITH A REMOTE ANNUNICATOR LOCATED AT THE FRONT DESK. THE FIRE ALARM SYSTEM WILL PROVIDE TOTAL-COVERAGE DETECTION AS DEFINED IN 2019 NFPA-72 (17.5.3.1) AND PER CITY OF PUYALLUP's REQUIREMENTS. THE FIRE ALARM SYSTEM WILL BE INTERFACED WITH THE (5) STOP ELEVATOR TO PROVIDE PHASE 1 ELEVATOR RECALL. THE FIRE ALARM SYSTEM SHALL MONITOR ALL FIRE ALARM INITIATING DEVICES, THE ERRCS / DAS SYSTEM (IF INSTALLED), ALL FIRE SPRINKLER FLOW DEVICES, AND FIRE SPRINKLER SUPERVISORY DEVICES. AUDIBLE AND VISIBLE OCCUPANT NOTIFICATION WILL BE PROVIDED THROUGHOUT ALL COMMON AREAS. TOTAL COVERAGE SMOKE DETECTION WILL BE PROVIDED THROUGHOUT THE BUILDING, INCLUDING ABOVE AND BELOW ALL SUSPENDED CEILINGS. SMOKE DETECTORS WITH 520Hz LOW FREQUENCY SOUNDER BASES WILL BE INSTALLED IN ALL HOTEL GUESTROOMS. FIRE ALARM VISIBLE OCCUPANT NOTIFICATION DEVICES SHALL BE PROVIDED IN GUESTROOMS WITH COMMUNICATION FEATURES PER ADAS 224.4 AND ACTIVATED BY THE ASSOCIATED GUESTROOM SMOKE DETECTORS AND/OR THE BUILDINGS FIRE ALARM SYSTEM. ACTIVATION OF THE GUESTROOM SMOKE DETECTORS WILL BE A LOCAL ONLY SUPERVISORY SIGNAL; IT WILL NOT DISPATCH THE FIRE DEPARTMENT. ACTIVATION OF THE FIRE ALARM SYSTEM SHALL ACTIVATE THE OUTDOOR HORN/STROBE, ALL AUDIBLE / VISUAL OCCUPANT NOTIFICATION DEVICES, ALL 520Hz LOW-FREQUENCY SMOKE DETECTOR SOUNDER BASES IN GUESTROOMS, RELEASE MAGNETICALLY HELD FIRE DOORS, AND CLOSE FIRE/SMOKE DAMPERS IN RATED WALLS. - HOMEWOOD SUITESSTOP WORK ORDER generated on 11/22/2024 by username 'Jeff Hill'.STOP WORK ORDER removed on 12/03/2024 by username 'Jeff Hill'.
|
Reference Number | Status | Type |
---|---|---|
E-20-0070 | Issued | Civil Construction Permit |
B-20-0180 | Permit(s) Issued | Commercial - New Construction |
E-20-0283 | Closed | Alternative Methods / Materials Request |
PRDE20220405 | Closed | Demolition |
PRFS20240423 | Permit(s) Issued | Fire Sprinklers |
PRCWSA20240533 | Closed | Certificate of Water/Sewer Availability |
PRCCP20240922 | Permit(s) Issued | Civil Construction Permit |
PRSG20241236 | Permit(s) Issued | Sign/Awning |
PRCWSA20241550 | Closed | Certificate of Water/Sewer Availability |
Date Uploaded | File Type | Name |
---|---|---|
04/04/2024 | Plans | SUBMITTAL DOCUMENTS |
04/04/2024 | Plans | SYSTEM CALCS |
04/04/2024 | Receipt | Receipt for transaction:2024-000657 |
05/03/2024 | Plans | FIRE ALARM PLANS (Stamped) |
05/08/2024 | Permit | Permit - Detailed |
05/08/2024 | Letter | Permit Job Card |
09/05/2024 | Letter | Permit Expiration Notice |
05/12/2025 | Letter | Permit Expiration Notice |
Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.