Summary

PRFA20251172
Fire Alarms
Returned for Correction
BCC PUYALLUP LLC
Addition
INSTALLATION OF 2 NEW BOOSTER POWER SUPPLY AND NOTIFICATION DEVICESTO THE TENANT IMPROVEMENT.ADDITIONS OF 168 NEW SMOKE DETECTORS, 81 NEW ABOVE CEILING, MONITORINGAND RELAY MODULES TO THE EXISTING FACP. - COP PUBLIC SAFETY BUILDING
08/29/2025

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Fire Review Failed 09/29/2025 09/11/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $657.50 $657.50 Paid 09/02/2025
Outstanding Fees Amount Paid Owing Date Paid
Resubmittal Fee $180.00 $0.00 $180.00 Not Paid


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$180.00    Add Fees to My Cart

Inspections

There are no inspections for this development permit application, or you are not authorized to view them.

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. Inspections are Monday - Thursday, no friday inspections • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • A remote annunciator located at the main entrance is required. If there is an existing annunciator on the exterior of the building it will need to be moved inside the main entrance. Please contact fire inspector for further information. • Exterior fire bell required outside fire sprinkler room. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72, 2019 • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • A pre-test shall be conducted and a printout of the location of the device, point number and descriptor shall be furnished to the inspector at final. Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20250117 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20250324 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCCP20250372 Permit(s) Issued Civil Construction Permit
PRFS20250872 Permit(s) Issued Fire Sprinklers
PRFS20250947 Permit(s) Issued Fire Sprinklers
PLPRE20240085 File Closed Pre-Application

Documents & Images

Date Uploaded File Type Name
08/29/2025 Other UL Certificate
08/29/2025 Plans ALARM PLANS
08/29/2025 Letter Incomplete Submittal Notice
09/02/2025 Receipt Receipt for transaction:2025-001730
09/02/2025 Form Application Form
09/11/2025 Letter Permit Review Correction Letter
09/11/2025 Plans CUT SHEETS (Flattened)