CITY OF PUYALLUP PERMITTING PORTAL

Permit Application Status

PRRNSF20220550


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRRNSF20220550
Residential - New Single Family Dwelling
Closed
106 CALIBER LLC
New
Residential, one- and two-family
NEW SFR
03/24/2022
01/12/2023
02/21/2024
08/25/2023

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Planning Review Approved 12/15/2022 12/15/2022
Engineering Storm Review Approved 12/15/2022 12/14/2022
Building Review Approved 12/15/2022 12/13/2022
Fire Review Approved 12/15/2022 12/13/2022
Engineering Review Approved 12/15/2022 12/06/2022
Engineering Traffic Review VOID 12/15/2022 12/06/2022
Engineering Storm Review Failed 09/06/2022 09/06/2022
Planning Review Failed 09/06/2022 09/06/2022
Building Review Failed 09/06/2022 08/31/2022
Fire Review Approved 09/06/2022 08/27/2022
Engineering Traffic Review Approved 09/06/2022 08/22/2022
Engineering Review Failed 09/06/2022 08/22/2022

Fees

Paid Fees Amount Paid Owing Date Paid
Exhaust Hood/Range Hood - Residential Fee $14.10 $14.10 Paid 01/11/2023
Exhaust Vent Fan (Bath) Fee $56.40 $56.40 Paid 01/11/2023
Furnace (up to 100,000 BTU) Fee $19.55 $19.55 Paid 01/11/2023
Gas Piping (Mechanical) Fee $7.60 $7.60 Paid 01/11/2023
Unclassified Appliance or Equipment Fee $14.10 $14.10 Paid 01/11/2023
Building Permit Fee $2,393.75 $2,393.75 Paid 01/11/2023
Mechanical Permit Fee $40.00 $40.00 Paid 01/11/2023
Plumbing Permit Fee $40.00 $40.00 Paid 01/11/2023
Plumbing 1&2 Family Dwellings Fee $240.00 $240.00 Paid 01/11/2023
Plumbing Fixtures Fee $65.00 $65.00 Paid 01/11/2023
Water Heater Fee $13.00 $13.00 Paid 01/11/2023
Building Plan Review Fee $1,646.94 $1,646.94 Paid 08/16/2022
Stormwater Report Review Fee $260.00 $260.00 Paid 08/16/2022
Planning Review Fee $30.00 $30.00 Paid 08/16/2022
Mechanical Plan Review Fee $98.64 $98.64 Paid 08/16/2022
Plumbing Plan Review Fee $232.70 $232.70 Paid 08/16/2022
WA State Building Code Council Fee (Residential) $6.50 $6.50 Paid 01/11/2023
Sewer System Development Charge $5,890.00 $5,890.00 Paid 01/11/2023
Water System Development Charge $4,260.00 $4,260.00 Paid 01/11/2023
Storm System Development Charge $3,560.00 $3,560.00 Paid 01/11/2023
Traffic Impact Fee (SFR/ADU) $4,230.00 $4,230.00 Paid 01/11/2023
Resubmittal Fee $130.00 $130.00 Paid 01/11/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Erosion And Sediment Inspection Partial Pass 1/30/2023 1/30/2023 01/30/2023
Jeff Hill ((253) 204-5633)
Footing/Setback Inspection Failed 2/7/2023 2/7/2023 02/07/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
02/07/2023
1:complete all thread, washers and rebar in strong wall footings as per plan 2:install pier pad forms, call for reinspect

Footing/Setback Inspection Passed 2/8/2023 2/8/2023 02/08/2023
Monty Johnson ((253) 770-3326)
Foundation/Rebar Inspection Passed 2/13/2023 2/13/2023 02/13/2023
Kevin Spruell ((253) 841-5590)
Plumbing Rough In Inspection Not Ready 3/3/2023 3/3/2023 03/03/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
03/03/2023
1. called in on error

Erosion And Sediment Inspection Failed 3/6/2023 3/6/2023 03/06/2023
Jeff Hill ((253) 204-5633)
Corrections:


Other/Miscellaneous
Carried Forward
03/06/2023
remove soils from silt fence (south side of site). install new silt fence on the west side of lot.

Storm Inspection Partial Pass 03/06/2023
Jeff Hill ((253) 204-5633)
Frame Inspection Partial Pass 3/8/2023 3/8/2023 03/08/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
03/08/2023
underfloor approved with correct washers installed at roto hammered anchor bolts.

Shear Wall Inspection Passed 4/5/2023 4/5/2023 04/05/2023
Monty Johnson ((253) 770-3326)
Plumbing Rough In Inspection Failed 5/2/2023 5/2/2023 05/02/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Outstanding
05/02/2023
fill dwv to top, mech approved to include gas pipe approval at 17 psi, frame not ready

Comment Building Div Inspection Not Ready 5/2/2023 5/2/2023 05/02/2023
Monty Johnson ((253) 770-3326)
Storm Inspection Not Ready 5/2/2023 5/2/2023 05/02/2023
Jeff Hill ((253) 204-5633)
Sidesewer Inspection Partial Pass 5/4/2023 05/08/2023
Jeff Hill ((253) 204-5633)
Combination Frame And Rough In Inspection Not Ready 5/9/2023 5/9/2023 05/09/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Carried Forward
05/09/2023
1. complete poly seal 2.provide vapor barrier under stairs in garage 3.provide access under stairs in garage 4.provide insulation and vapor barrier at tub on main floor 5. provide blocks at roof in entry way where rafters bare on wall 6.provide positive connection at rafters in entry 7. provide roof venting at east roof over master bath /bedroom 8. move heat run from unconditioned space at great room 9.provide insulation baffles at vault in great room 10. DID NOT OPEN PLANS OR TRUSS SPECS 11.NOT A COMPLETE LIST 12.NOT READY

Sidesewer Inspection Partial Pass 5/10/2023 05/15/2023
Jeff Hill ((253) 204-5633)
Combination Frame And Rough In Inspection Failed 5/23/2023 5/23/2023 05/23/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
05/23/2023
1. complete poly seal 2.provide vapor barrier under stairs in garage 3.provide access under stairs in garage 4.provide insulation and vapor barrier at tub on main floor 5. provide blocks at roof in entry way where rafters bare on wall 6.provide positive connection at rafters in entry 7. provide roof venting at east roof over master bath /bedroom 8. move heat run from unconditioned space at great room 9.provide insulation baffles at vault in great room 10. DID NOT OPEN PLANS OR TRUSS SPECS 11.NOT A COMPLETE LIST 12.NOT READY

Other/Miscellaneous
Carried Forward
05/23/2023
1:seperate back to back boxes in garage /house wall 2:provide dbl stud under girder in front bedroom 3:fire block fireplace stand 4:provide engineers ok on 7 1/2" beam depth at roof rack in lieu of 9" as per plan 5:block trusses at upper floor bearing walls while leaving space for ventilation 6:pour slab in garage at storage under stairs with plastic under also will need to rock bottom of stairs by final 7:plumb and mech ok ok to insulate

Comment Building Div Inspection Passed w/ Conditions 5/31/2023 5/31/2023 05/31/2023
Kevin Spruell ((253) 841-5590)
Corrections:


Other/Miscellaneous
Outstanding
05/31/2023
1. provide letter from engineer for over cut beam from previous list 2.provide insulation baffles that where missing as discussed with contractor 3. ok to cover

Comment Building Div Inspection Partial Pass 6/5/2023 6/5/2023 06/06/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
06/06/2023
not required for residential

Comment Building Div Inspection Passed 6/29/2023 6/29/2023 06/29/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Outstanding
06/29/2023
shower pan ok, still need letter from engineer on cut beam prior to final

Erosion And Sediment Inspection Passed 08/23/2023
Jeff Hill ((253) 204-5633)
Corrections:


Other/Miscellaneous
Outstanding
03/06/2023
remove soils from silt fence (south side of site). install new silt fence on the west side of lot.

Engineering Final Inspection Failed 8/23/2023 8/23/2023 08/23/2023
Jeff Hill ((253) 204-5633)
Corrections:


Other/Miscellaneous
Carried Forward
08/23/2023
connect all down spouts

Other/Miscellaneous
Carried Forward
08/23/2023
install carson boxes marked Sewer over sewer clean outs.

Other/Miscellaneous
Carried Forward
08/23/2023
raise the yard drain and clean out for the infiltration trench. The clean out will need a carson box marked clean out

Other/Miscellaneous
Carried Forward
08/23/2023
The front yard landscaping must be completed. The backyard soils must be stabilized.

Energy (Insulation) Inspection VOID 8/23/2023 8/23/2023 08/23/2023
Monty Johnson ((253) 770-3326)
Frame Inspection VOID 8/23/2023 8/23/2023 08/23/2023
Monty Johnson ((253) 770-3326)
Plumbing Final Inspection Not Ready 8/23/2023 8/23/2023 08/23/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
08/23/2023
provide engineering final prior to building final

Mechanical Final Inspection Not Ready 8/23/2023 8/23/2023 08/23/2023
Monty Johnson ((253) 770-3326)
Residential Final Inspection Failed 8/23/2023 8/24/2023 08/24/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
08/24/2023
1:provide engineering final prior to building final

Plumbing Final Inspection Passed 8/25/2023 8/25/2023 08/25/2023
Monty Johnson ((253) 770-3326)
Mechanical Final Inspection Passed 8/25/2023 8/25/2023 08/25/2023
Monty Johnson ((253) 770-3326)
Residential Final Inspection Failed 8/25/2023 8/25/2023 08/25/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
08/25/2023
FINAL PENDING ENGINEERING FINAL

Building Final Inspection Failed 8/25/2023 8/25/2023 08/25/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Carried Forward
08/25/2023
FINAL PENDING ENGINEERING FINAL

Sidesewer Inspection Passed 08/25/2023
Jeff Hill ((253) 204-5633)
Storm Inspection Passed 5/3/2023 08/25/2023
Jeff Hill ((253) 204-5633)
Engineering Final Inspection Passed 8/25/2023 8/25/2023 08/25/2023
Jeff Hill ((253) 204-5633)
Corrections:


Other/Miscellaneous
Resolved
08/25/2023
connect all down spouts

Other/Miscellaneous
Resolved
08/25/2023
install carson boxes marked Sewer over sewer clean outs.

Other/Miscellaneous
Resolved
08/25/2023
raise the yard drain and clean out for the infiltration trench. The clean out will need a carson box marked clean out

Other/Miscellaneous
Resolved
08/25/2023
The front yard landscaping must be completed. The backyard soils must be stabilized.

Storm Inspection Passed 08/25/2023
Jeff Hill ((253) 204-5633)
Residential Final Inspection Passed 08/25/2023
Monty Johnson ((253) 770-3326)
Plumbing Rough In Inspection VOID 08/25/2023
Monty Johnson ((253) 770-3326)
Corrections:


Other/Miscellaneous
Outstanding
03/03/2023
1. called in on error

Plumbing Rough In Inspection VOID 08/25/2023
Monty Johnson ((253) 770-3326)
Combination Frame And Rough In Inspection VOID 08/25/2023
Monty Johnson ((253) 770-3326)
Building Final Inspection Passed 08/25/2023
Monty Johnson ((253) 770-3326)

Conditions

Condition Status Category
Building Permit Standard Conditions Open Standard Conditions
* Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
Engineering Residential Standard Conditions Open Standard Conditions
* Prior to STARTING the applicant shall request an erosion and sediment control inspection using the CityView permit portal at least 48 hours in advance of job start ** SEDIMENT CONTROL AND EROSION PROCEDURES SHALL BE PRACTICE TO ELIMINATE AND PREVENT OFF SITE DAMAGE. STORMWATER RUNOFF ORIGINATING UPGRADE OF EXPOSED AREAS SHALL BE CONTROLLED TO REDUCE EROSION AND SEDIMENT LOSS DURING THE PERIOD OF EXPOSURE. *** STORMWATER CONTROL OF ROOF DOWNSPOUTS MUST BE CONTROLLED. FOLLOW THE APPROVED STORMWATER REPORT **** THE APPROVED STORMWATER MAINTENANCE AGREEMENT MUST BE RECORDED PRIOR TO THE CITY GRANTING A CERTIFIACATE OF OCCUPANCEY. ONCE RECORDED PROVIDE THE CITY WITH THE AUDITOR FILE NUMBER (AFN) FOR VERIFICATION. * THE APPLICANT IS RESPONSIBLE TO CALL THE ENGINEERING INSPECTOR AT 253-435-3650 TO SCHEDULE A SIDE SEWER INSPECTION PRIOR TO BACKFILLING. * SIDEWALK AND APPROACH MUST BE POURED PER CITY STANDARDS. NO WORK SHALL BE DONE IN OR ON THE PUBLIC RIGHT OF WAY WITHOUT A LICENSED AND BONDED CONTRACTOR FIRST OBTAINING A RIGHT OF WAY PERMIT. * DRIVEWAY APPROACH MUST BE A MINIMUM OF 15' WIDE AND A MAXIMUM OF 30' WIDE. THE TOTAL WIDTH OF ALL DRIVEWAYS SHALL NOT EXCEED 50% OF THE PROPERTY FRONTAGE, PER CITY STANDARDS. * DRIVEWAY MAY NOT EXCEED A 10% GRADE AT ANY POINT OR AS DIRECTED BY THE CITY OF PUYALLUP. * SANITARY SEWER CLEAN-OUT TO BE INSTALLED AT THE PROPERTY LINE. IF LOCATED IN THE DRIVEWAY AREA, IT MUST BE PLACED IN A FRAME AND COVERED, PER CITY STANDARDS. * THE BUILDER/OWNER SHALL BE RESPONSIBLE FOR KEEPING THE EXISTING RIGHT-OF-WAY FREE OF DEBRIS AND DIRT. ANY VIOLATION OF PMC CHAPTER 21.14 PERTAINING TO CLEARING, FILLING AND GRADING, EROSION AND SEDIMENT CONTROL, AND STORM WATER DISCHARGES SHALL BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW. * ANY ADDITION/EXPANSION TO THE FOOTPRINT OF THE BUILDING INCLUDING DECKS AND PORCHES NOT ORIGINALLY SHOWN ON THE APPROVED SET OF PLANS MUST OBTAIN PROPER PERMITS PRIOR TO CONSTRUCTION. * THE APPLICANT IS RESPONSIBLE TO CALL THE UTILITY NOTIFICATION CENTER AT 1-800-424-5555 BEFORE BEGINNING ANY EXCAVATION. CALL BEFORE YOU DIG, IT'S THE LAW. * ANY CODE REQUIREMENT THAT MAY HAVE BEEN OVERLOOKED IN THIS PLAN REVIEW DOES NOT IMPLY THAT THE REQUIREMENTS HAVE BEEN WAIVED. * ALL NEW OR EXISTING MULTI USE AND COMMERCIAL FACILITIES ARE REQUIRED TO INSTALL, AT THE SERVICE CONNECTION AN APPROVED REDUCED PRESSURE BACKFLOW PREVENTION ASSEMBLY (RPBA), PER CITY STANDARDS.
Frontage Improvements - Residential Infill Lot Resolved Prior to Issuance
Engineering Division
In accordance with Puyallup Municipal Code 11.08.135, residential infill lot projects that qualify as substantial improvements (the cost of which equals or exceeds 50% of the market value of the structure before the “start of construction” of the improvement) are required to complete improvements along the property's street frontage. Your project will be required to complete frontage improvements which may include curb, gutter, planter strips, street trees, sidewalks, storm drainage, street lighting, and one-half street paving (only required if the existing pavement condition is poor) as determined by Development Engineering. The building permit shall not be issued until the frontage improvement designs have been approved by the City and a right-of-way or civil construction permit issued. A right-of-way permit is required if there is existing vertical curb in good condition and a civil construction permit is required if there is no existing vertical curbing. The building permit shall be conditioned in such a manner that building occupancy will not be granted until the frontage improvements are completed and approved. The subject site may qualify for the fee-in-lieu program in which the applicant may request and submit justification to pay a fee rather than constructing all or part of the required frontage improvements. Allowance of fee-in-lieu shall be at the discretion of the City and may be denied if the City Engineer determines it will be more beneficial to the public to have frontage improvements built along the street frontage adjoining the property or access to the property. The justification to allow use of the fee-in-lieu program shall not be based on cost savings to the applicant in comparison with constructing required improvement adjacent to the property.
Stormwater Maintenance Agreement (SWA) Resolved Prior to Occupancy
Engineering Division
The approved Stormwater Maintenance Agreement shall be recorded prior to the City granting a certificate of occupancy. Once recorded, provide the City with the Auditor File Number (AFN) for verification.
Miscellaneous Condition Resolved Prior to Occupancy
Engineering Division
Fontage improvements must be constructed and approved prior to occupancy. LL 08/22/2022
Miscellaneous Condition Resolved Prior to Completion
Development & Permitting Services
A right-of-way permit is required to be issues prior to construction of the improvements. Street trees are required where planter space is available, consistent with PMC 11.28 and the VMS. Please include a street tree as part of your right-of-way permit submittal. The City also has a companion design manual – the Vegetation Management Standards (VMS) manual – found here: www.cityofpuyallup.org/puyallupvms. Please provide a landscape plan indicating street trees consistent with the city’s requirements as outlined in the Municipal Code (PMC 20.58), the Vegetation Management Standards (VMS) manual (Chapters 8.0 and 12.0) and city Public Works standards, found here: www.cityofpuyallup.org/engdetailsroadway. Include public works Standards 01.02.02, 01.02.03, 01.02.04, 01.02.08A in your final design plans.
Miscellaneous Condition Resolved Prior to Issuance
Development & Permitting Services
NEED COP BUS LICENSE, FEES PAID & PSD LETTER PRIOR TO ISSUANCE ~ JJ REC'D ALL REQUIRED DOCS/ITEMS VIA EMAIL 1.11.2023 ~ JJ

Related Permit & Planning Applications

There are no related items for this permit application.

Documents & Images

Date Uploaded File Type Name
12/16/2022 Report Revised Structural Calcs_Lot 32 (Stamped)
12/16/2022 Plans Revised Construction Plans_Lot 32 (Stamped)
12/16/2022 Plans Revised Site Plan_Lot 32 (Stamped)
12/16/2022 Plans Revised STORM SITE Plan_Lot 32 (Stamped)
12/16/2022 Plans Revised_Floor Truss Layout_Lot 32 (Stamped)
12/16/2022 Plans Revised_Roof Truss Layout_Lot 32 (Stamped)
12/16/2022 Report Floor Truss Seals Stamped_2504 12th Ave NW_Lot 32 (Stamped)
12/16/2022 Report Roof Truss Seals Stamped_2504 12th Ave NW_Lot 32 (Stamped)
12/16/2022 Report Revised STORM REPORT_Lot 32 (Stamped)
12/16/2022 Report revised temp Sediment & Erosion Control_Lot 32 (Stamped)
01/11/2023 Receipt Receipt for transaction:2023-000046
02/13/2023 Report Inspection Report (Foundation/Rebar Inspection)
03/03/2023 Report Inspection Report (Plumbing Rough In Inspection)
05/02/2023 Report Inspection Report (Plumbing Rough In Inspection)
05/09/2023 Report Inspection Report (Combination Frame And Rough In Inspection)
05/23/2023 Report Inspection Report (Combination Frame And Rough In Inspection)
05/31/2023 Report Inspection Report (Comment Building Div Inspection)
06/05/2023 Plans PRRNSF20220550 SS ASBUILT
08/23/2023 Report Inspection Report (Engineering Final Inspection)
08/28/2023 Agreement 2504 12TH AVE NW PRRNSF20220550 RECORDED SWA


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.