CITY OF PUYALLUP PERMITTING PORTAL

Planning Application Status

PLPSP20240062


Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PLPSP20240062
Fred Meyer Distribution Center
Preliminary Site Plan
Preliminary Site Plan
File Closed
06/12/2024
FM RETAIL SERVICES INC

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Engineering Review No Comments 08/27/2024 09/03/2024
Engineering Traffic Review No Comments 08/27/2024 08/29/2024
Planning Review No Comments 08/27/2024 08/28/2024
Building Review No Comments 08/27/2024 08/23/2024
Fire Review No Comments 08/27/2024 08/09/2024

Fees

Paid Fees Amount Paid Owing Date Paid
SEPA Checklist Fee (with planning permit) $250.00 $250.00 Paid 06/18/2024
Preliminary Site Plan Fee $690.00 $690.00 Paid 06/18/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Application(s) will not be processed until outstanding fees have been paid in full.

$0.00

Meetings

There are no hearings for this planning application.

Conditions

Condition Status Category
Sign Posted On Site Resolved Public Noticing
Planning Division
Public notice sign must be posted on site in a publically visible location.
Signed Affidavit Resolved Public Noticing
Planning Division
Signed Affidavit must be provided.
Miscellaneous Condition Resolved Submit With Building Permit Application
Building Division
-- Project specific notes: 1. Building plans will need to be complete with all building, mechanical, plumbing, energy code items and accessibility requirements that apply to project. Current codes are the 2021 Washington State codes with Puyallup amendments. In general, local amendments other than administrative processes are limited to Fire Code elements for Fire Alarm, Fire Flow, Fire Sprinklers and Fire Access. Please see the Puyallup Municipal Code chapter 16 and 17. 2. Separate permits are required for each sign type (wall mounted, pole, etc.). 3. Modular buildings (guard shack) will need to be permitted through the Washington State Department of Labor and Industries: https://lni.wa.gov/licensing-permits/manufactured-modular-mobile-structures/modular-other-mobile-structures/. Approved modular buildings must display the Gold ID tag from L&I. 4. The City’s Building Division will review and inspect the following: Setbacks, Footings, Skirting, Utility Connections, Landings, Stairs, Ramps, and Railings. 5. Retaining walls less than 4ft in height (measured from the top of the wall to the bottom of the footing), unless supporting a surcharge or impounding Class I, II or IIIA liquids, are exempt from permit. -- Building General Notes: a. All electrical is permitted by the Washington State Department L & I. b. For all accessible requirements, the City adopted the 2021 IBC / WAC 51-50 and the ICC A117.1-2017 standard. c. A Geotechnical Report for the building site area is required at the time of submittal.
Final Landscape Plan - Tree Protection Resolved Submit With Civil Permit Application
Planning Division
Existing trees to be retained must be clearly marked on the final clearing and grading plan, and final landscape plan. Tree protection fencing and signage shall follow the city standard detail, see appendix 20.5. Standard detail shall be included on all plan sets with vegetation which is scheduled for retention and protection. All critical root protection zones (CRPZ) shall be shown on plan sets in diameter from the center of the tree. In determining tree CRPZ, the following standards shall be used.In establishing the extent of the Critical Root Protection Zone (CRPZ) for individual significant trees, groupings of significant trees, a stand of significant trees, or a heritage tree the following formula shall be used: Individual tree diameter (in inches) X 2, converted into feet = CRPZ, in diameter (Example: 20” tree X 2 = 40’ CRPZ diameter). The following minimum performance standards shall be used to determine the extent of allowable impacts to the CRPZ of significant trees: For significant trees, a minimum of 50 percent of the critical root zone must be preserved at natural grade, with natural ground cover. The protection zone may be irregular. The plan set shall provide a total square footage of CRPZ area and show the % of disturbance area. For heritage trees, a minimum of 75 percent of the critical root zone must be preserved at natural grade with natural ground cover. The protection zone may be irregular. The plan set shall provide a total square footage of CRPZ area and show the % of disturbance area. No cut or fill greater than four (4) inches in depth may be located closer to the tree trunk than ½ the CRPZ radius distance. (Example, 20-inch DBH tree has a 40’ CRPZ area (in diameter) - meaning no cut or fill greater than 4” in depth is allowed within 20’ of the tree trunk). No cut or fill within the distance from the tree which is three (3) times the trunk DBH is allowed. (Example, 20-inch DBH tree X 3 = 60”, meaning no cut is allowed within 60-inches of a tree which has a 20-inch diameter trunk). These criteria represent minimum standards for determining whether or not a tree may be required to be retained. Greater impacts may be allowed, provided that all design alternatives have been proven unfeasible and that a pre-conditioning and after care mitigation program is established. See section 10.1 of the VMS, and referenced appendices for more information.
Miscellaneous Planning Condition Resolved
Planning Division
Building elevations for guard shack must be submitted with the associated building permit application.
Miscellaneous Condition Resolved Submit With Civil Permit Application
Development & Permitting Services
A few things to consider for civil application: Check impervious surface calcs. Plans say 'Pervious Area Removed' is 2360 sq ft, yet the TIR says 1505 sq ft of added pavement in the Project Overview section. Are these supposed to be the same? Clarify if they are not. Also, there is no buffer identified for the nearby wetland. We don't anticipate this critical area will impact the project, but this issue should be addressed.

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20241098 Closed Commercial - Tenant Improvement/Remodel
PRCCP20241545 Permit(s) Issued Civil Construction Permit
PRPF20260314 Submittals Incomplete Pre-Fabricated Building
PLPRE20230119 File Closed Pre-Application

Documents & Images

Date Uploaded File Type Name
06/12/2024 Plans SITE PLAN - 2 - 18510-D-CIVL-2024-05-24-PRLM
06/12/2024 Form APPLICATION FORM
06/12/2024 Form SEPA CHECKLIST
06/13/2024 Letter Initial Submittal Incompleteness Letter (Generate/Send Initial Submittal Incompleteness Letter)
06/17/2024 Other 3 - 18510-R-TIR-2024-05-24-PRLM
06/18/2024 Receipt Receipt for transaction:2024-001294
06/24/2024 Letter Determination of Completeness Letter
06/27/2024 Letter NOA Legal Notice (Send NOA Legal Notice for Publication)
06/27/2024 Letter NOA Site Posting Template (Send NOA Site Posting Sign)
07/01/2024 Letter Notice of Application Mailer (Send NOA Surrounding Owner Notice)
07/01/2024 PLPSP20240062 Mailing List
07/15/2024 PLPSP20240062 NOA Affidavit
07/17/2024 Email Public Comment - Ken Farthing (10001 Dechaux Road Edgewood, WA)
07/17/2024 Email Public Comment - Nancy Todd (10416 48th St Ct E Puyallup, WA)
07/17/2024 Email Public Comment - Brianna Chavez (10217 Todd Rd E Puyallup, WA) #2
07/17/2024 Email Public Comment - Brianna Chavez (10217 Todd Rd E Puyallup, WA) #1
07/17/2024 Email Public Comment - Steve Muckelrath (10014 Dechaux Rd Edgewood, WA)
07/17/2024 Email Public Comment - Rick Drahos (9821 Dechaux Rd Edgewood, WA)
07/24/2024 Email PROJECT ID: PLPSP20240062 - NOTICE OF COMPLETE APPLICATION
09/05/2024 Letter Final DRT Letter
09/05/2024 SEPA Determination


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.