Summary

PRFA20241975
Fire Alarms
Permit(s) Issued
WAL-MART RE BUSINESS TR 2403
Alteration/Remodel
(20) ALARMS: PANEL UPGRADE TO REFELECT CHANGES TO THE REMODELED AREAS THROUGHOUT THE STORE. ~WALMART #2403 INTERIOR REMODEL
12/19/2024
02/27/2025
08/26/2025

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
02/27/2025 FIRE ALARM PLANS - RESUB (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 02/26/2025 02/27/2025
Fire Review Failed 01/29/2025 01/15/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (Alteration) Fee $345.00 $345.00 Paid 12/19/2024
Resubmittal Fee $180.00 $180.00 Paid 01/27/2025
Building Division Fee (Hourly) $180.00 $180.00 Paid 02/27/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • If there is an existing annunciator on the exterior of the building it will need to be moved inside the main entrance. Please contact fire inspector for further information. • Above ceiling detection is required. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • Pre-test shall be conducted with a printout for inspector at time of inspection. • Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • RTU’S and smoke dampeners will be required to be tested during inspection. RTU’S of 2000cfm or higher are required to be monitored and will require shutdown. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first.

Related Permit & Planning Applications

Reference Number Status Type
PRCTI20241053 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRCTI20241065 Permit(s) Issued Commercial - Tenant Improvement/Remodel
PRFS20250019 Permit(s) Issued Fire Sprinklers
PRFW20250341 Closed Fire Watch
PRFA20250391 Permit(s) Issued Fire Alarms

Documents & Images

Date Uploaded File Type Name
12/19/2024 Receipt Receipt for transaction:2024-002629
12/20/2024 Letter Incomplete Application Notice
01/15/2025 Letter Permit Review Correction Letter
01/15/2025 Form 1975 APP (Flattened)
01/15/2025 Plans 1975 CUT SHEETS (DUPLICATE)
01/15/2025 Plans FIRE ALARM DEVICE CUT SHEET
01/27/2025 Receipt Receipt for transaction:2025-000170
02/11/2025 Plans FLOOR PLAN - RESUB
02/11/2025 Plans FIRE ALARM SYSTEM CALC'S - RESUB
02/27/2025 Plans FIRE ALARM PLANS - RESUB (Stamped)
02/27/2025 Letter Permit - Detailed
02/27/2025 Receipt Receipt for transaction:2025-000407