| Paid Fees | Amount | Paid | Owing | Date Paid |
|---|---|---|---|---|
| Building Permit Fee | $2,393.75 | $2,393.75 | Paid | 06/21/2023 |
| Building Plan Review Fee | $1,555.94 | $1,555.94 | Paid | 05/30/2023 |
| WA State Building Code Council Fee (Commercial) | $25.00 | $25.00 | Paid | 06/21/2023 |
| Building Re-Inspection Fee | $180.00 | $180.00 | Paid | 09/20/2023 |
| Outstanding Fees | Amount | Paid | Owing | Date Paid |
| No outstanding fees. | ||||
| Totals: | $4,154.69 | $4,154.69 | $0.00 |
Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.
$0.00
| Inspection | Outcome | Requested | Scheduled | Date Inspected |
|---|---|---|---|---|
| Roof Sheathing Inspection | Not Ready | 8/14/2023 | 8/14/2023 | 08/14/2023 |
| Kevin Spruell ((253) 841-5590) | ||||
|
Corrections:
Other/Miscellaneous
Carried Forward
08/14/2023
1. no contact from contractor prior to 8:30 am
2.no one on site at time of inspection 11:05 am
|
||||
| Building Final Inspection | Not Ready | 8/24/2023 | 8/24/2023 | 08/24/2023 |
| Kevin Spruell ((253) 841-5590) | ||||
|
Corrections:
Other/Miscellaneous
Carried Forward
08/24/2023
1.no one on site from roofing company at time of inspection 1:15 pm
2.no one made contact prior to 8:30 am to meet on site
3. not ready
|
||||
| Re-Roof Inspection | Failed with Fee | 9/13/2023 | 9/13/2023 | 09/14/2023 |
| Kevin Spruell ((253) 841-5590) | ||||
|
Corrections:
Other/Miscellaneous
Carried Forward
09/14/2023
1. no one on site at time of inspection 1:10 pm
2. no contact from roofing contractor as previously discussed
3.talked to fred meyer representative at time of inspection he was not notified of pending inspection today
4.pay 180.00 reinspect fee prior to scheduling next inspection
|
||||
| Re-Roof Inspection | Not Ready | 9/25/2023 | 9/25/2023 | 09/25/2023 |
| Kevin Spruell ((253) 841-5590) | ||||
|
Corrections:
Other/Miscellaneous
Carried Forward
09/25/2023
1. no one on site at time of inspection 1:10 pm
2. no contact from roofing contractor as previously discussed
3.talked to fred meyer representative at time of inspection he was not notified of pending inspection today
4.pay 180.00 reinspect fee prior to scheduling next inspection
|
||||
|
Other/Miscellaneous
Carried Forward
09/25/2023
1. no one on site at time of inspection 11:25 am
2. called contractor he had to leave
|
||||
| Building Final Inspection | Not Ready | 9/27/2023 | 9/27/2023 | 09/27/2023 |
| Kevin Spruell ((253) 841-5590) | ||||
|
Corrections:
Other/Miscellaneous
Resolved
09/27/2023
1.no one on site from roofing company at time of inspection 1:15 pm
2.no one made contact prior to 8:30 am to meet on site
3. not ready
|
||||
|
Other/Miscellaneous
Carried Forward
09/27/2023
1. set up time to due core sample with inspector present as discussed with contractors
2. provide all warranties as discussed at time of next inspection
3. not ready
|
||||
| Re-Roof Inspection | Not Ready | 9/28/2023 | 9/28/2023 | 09/29/2023 |
| Kevin Spruell ((253) 841-5590) | ||||
|
Corrections:
Other/Miscellaneous
Resolved
09/29/2023
1. no one on site at time of inspection 1:10 pm
2. no contact from roofing contractor as previously discussed
3.talked to fred meyer representative at time of inspection he was not notified of pending inspection today
4.pay 180.00 reinspect fee prior to scheduling next inspection
|
||||
|
Other/Miscellaneous
Resolved
09/29/2023
1. no one on site at time of inspection 11:25 am
2. called contractor he had to leave
|
||||
|
Other/Miscellaneous
Carried Forward
09/29/2023
1. core sample approved
2. complete fastener attachment at all coping and flashing per city approved plans as discussed with contractor
|
||||
| Re-Roof Inspection | Not Ready | 10/13/2023 | 10/13/2023 | 10/13/2023 |
| Monty Johnson ((253) 770-3326) | ||||
|
Corrections:
Other/Miscellaneous
Resolved
10/13/2023
1. core sample approved
2. complete fastener attachment at all coping and flashing per city approved plans as discussed with contractor
|
||||
|
Other/Miscellaneous
Carried Forward
10/13/2023
arrived on site 11:55 talked to roofer he stated there was nothing to inspect
|
||||
| Building Final Inspection | Passed | 10/18/2023 | 10/18/2023 | 10/18/2023 |
| Kevin Spruell ((253) 841-5590) | ||||
|
Corrections:
Other/Miscellaneous
Resolved
10/18/2023
1. set up time to due core sample with inspector present as discussed with contractors
2. provide all warranties as discussed at time of next inspection
3. not ready
|
||||
| Comment Building Div Inspection | VOID | 10/18/2023 | ||
| Kevin Spruell ((253) 841-5590) | ||||
| Roof Sheathing Inspection | VOID | 10/18/2023 | ||
| Kevin Spruell ((253) 841-5590) | ||||
|
Corrections:
Other/Miscellaneous
Outstanding
08/14/2023
1. no contact from contractor prior to 8:30 am
2.no one on site at time of inspection 11:05 am
|
||||
| Re-Roof Inspection | VOID | 10/18/2023 | ||
| Kevin Spruell ((253) 841-5590) | ||||
| Condition | Status | Category |
|---|---|---|
| Building Permit Standard Conditions | Open | Standard Conditions |
|
Building Division
* Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
|
||
| Re-Roof Conditions | Open | Standard Conditions |
|
RE-ROOF
1) PROVIDE MANUFACTURES SPECIFICATIONS AND INSTALLATION DETAILS ON SITE FOR INSPECTION
2) CALL FOR REQUIRED INSPECTIONS PRIOR TO COVER; REQUIRED FOR SHEATHING REPLACEMENT, STRUCTURAL REPAIR OR INSULATION
3) PROVIDE INSPECTION ACCESS
4) PROVIDE A COPY OF THE PERMIT ON SITE
***MUST PROVIDE DRIP EDGE ON ALL ROOF EDGES***
|
||
Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.