Review Type |
Outcome |
Est. Completion Date |
Completed |
Engineering Civil Review
|
Approved
|
02/20/2024
|
02/16/2024
|
|
|
|
See Document Markup
Provide pipe slope, diameter and material. [retaining wall specs, pg 1]
|
|
See Document Markup
Show the retaining wall pipe connecting to the on-site stormwater mitigation system on a separate sheet with all other proposed water/sewer/stormwater existing and proposed utilities. Show any potential utility conflicts. Be sure to include the conveyance pipe material, diameter, slope and cover. Note: all city allowed pipe types required 3' of cover unless using ductile iron. [site plan, pg 1]
|
|
See Document Markup
Show the proposed stormwater detention system. [site plan, pg 1]
|
|
See Document Markup
Remove development engineering approval block, this stamp is reserved for civil construction permits. [civils, pg 1]
|
|
See Document Markup
Create a note that reads "This building permit was reviewed solely for the construction of the proposed retaining wall and inherent drainage. No other construction related activities are permitted per this site plan. [site plan, pg 1]
|
|
See Document Markup
This site plan will be used for construction of the proposed wall, include the wall detail on a separate sheet. [site plan, pg 1]
|
Engineering Review
|
Approved
|
02/20/2024
|
02/16/2024
|
|
|
|
See Document Markup
Depict and label the proposed roof drain as depicted on civil plan C5.1 that runs parallel to the retaining wall. Depict and label the connection of the roof drain pipe to the on-site stormwater mitigiation system. Include the conveyance pipe material, diameter, slope, and cover. [Site Plan, sheet C3.0]
|
|
See Document Markup
Include site address (1402 S MERIDIAN) and tax parcel number (7730000281) on the site plan. [Site Plan, Sheet C3.0]
|
|
See Document Markup
Include the Block Wall detail from civil plans sheet C4.2 depicting block wall, perforated drain pipe, and storm pipe casing on this page. Address any discrepancies between the Block Wall detail and the Section detail depicted below. [Structural Plans, Sheet RWS0.1]
|
|
See Document Markup
Depict and label the proposed roof drain and landscape swale located behind the retaining wall on all details. Label separation from wall and other pipes. [Structural Plans, Sheet RWS0.1]
|
Building Review
|
Approved
|
02/20/2024
|
02/07/2024
|
|
|
|
See Document Markup
Please provide the referenced Geotechnical Engineering Report [RETAINING WALL - Specs]
|
|
See Document Markup
Please verify the TW and BW elevations. With the current numbers, the total height at this section would be 4.6', but it's noted as 1.5' [STRUCTURAL CALCS, page 2 of 10].
|
Planning Review
|
Approved
|
02/20/2024
|
02/07/2024
|
|
|
Engineering Civil Review
|
Failed
|
12/05/2023
|
12/04/2023
|
|
|
|
See Document Markup
Provide pipe slope, diameter and material. [retaining wall specs, pg 1]
|
|
See Document Markup
Show the retaining wall pipe connecting to the on-site stormwater mitigation system on a separate sheet with all other proposed water/sewer/stormwater existing and proposed utilities. Show any potential utility conflicts. Be sure to include the conveyance pipe material, diameter, slope and cover. Note: all city allowed pipe types required 3' of cover unless using ductile iron. [site plan, pg 1]
|
|
See Document Markup
Show the proposed stormwater detention system. [site plan, pg 1]
|
|
See Document Markup
Remove development engineering approval block, this stamp is reserved for civil construction permits. [civils, pg 1]
|
|
See Document Markup
Create a note that reads "This building permit was reviewed solely for the construction of the proposed retaining wall and inherent drainage. No other construction related activities are permitted per this site plan. [site plan, pg 1]
|
|
See Document Markup
This site plan will be used for construction of the proposed wall, include the wall detail on a separate sheet. [site plan, pg 1]
|
Engineering Review
|
Failed
|
12/05/2023
|
12/04/2023
|
|
|
|
See Document Markup
Depict and label the proposed roof drain as depicted on civil plan C5.1 that runs parallel to the retaining wall. Depict and label the connection of the roof drain pipe to the on-site stormwater mitigiation system. Include the conveyance pipe material, diameter, slope, and cover. [Site Plan, sheet C3.0]
|
|
See Document Markup
Include site address (1402 S MERIDIAN) and tax parcel number (7730000281) on the site plan. [Site Plan, Sheet C3.0]
|
|
See Document Markup
Include the Block Wall detail from civil plans sheet C4.2 depicting block wall, perforated drain pipe, and storm pipe casing on this page. Address any discrepancies between the Block Wall detail and the Section detail depicted below. [Structural Plans, Sheet RWS0.1]
|
|
See Document Markup
Depict and label the proposed roof drain and landscape swale located behind the retaining wall on all details. Label separation from wall and other pipes. [Structural Plans, Sheet RWS0.1]
|
Planning Review
|
Approved
|
12/05/2023
|
11/15/2023
|
|
|
Building Review
|
Failed
|
12/05/2023
|
11/14/2023
|
|
|
|
See Document Markup
Please provide the referenced Geotechnical Engineering Report [RETAINING WALL - Specs]
|
|
See Document Markup
Please verify the TW and BW elevations. With the current numbers, the total height at this section would be 4.6', but it's noted as 1.5' [STRUCTURAL CALCS, page 2 of 10].
|