| Review Type |
Outcome |
Est. Completion Date |
Completed |
|
Public Works Collection Review
|
Approved
|
12/08/2025
|
12/02/2025
|
|
|
|
|
Engineering Traffic Review
|
Approved
|
12/08/2025
|
11/25/2025
|
|
|
|
|
Public Works Water Review
|
Approved
|
12/08/2025
|
11/24/2025
|
|
|
|
|
|
See Document Markup
Civil Plans C.02: Privately owned ecology blocks were placed on each side of this public fire hydrant to protect it from parking vehicles traffic. These concrete blocks are not crash worthy, and must be moved behind the public right-of-way to protect the City from any liability issues.
|
|
Public Works Streets Review
|
Approved
|
12/08/2025
|
11/21/2025
|
|
|
|
|
Engineering Traffic Review
|
Approved
|
01/17/2025
|
01/13/2025
|
|
|
|
|
Planning Review
|
Failed
|
01/17/2025
|
01/13/2025
|
|
|
|
|
|
Other/Miscellaneous
Provide a plan that outlines how the affected temporary gravel parking lot site area will be restored back to its original conditions once the associated site construction for the ELC is complete. Include details regarding gravel removal and reseeding.
|
|
Fire Review
|
Approved
|
01/17/2025
|
01/09/2025
|
|
|
|
|
Public Works Water Review
|
Failed
|
01/17/2025
|
01/08/2025
|
|
|
|
|
|
See Document Markup
Civil Plans C.02: Privately owned ecology blocks were placed on each side of this public fire hydrant to protect it from parking vehicles traffic. These concrete blocks are not crash worthy, and must be moved behind the public right-of-way to protect the City from any liability issues.
|
|
Public Works Streets Review
|
Approved
|
01/17/2025
|
01/07/2025
|
|
|
|
|
Engineering Civil Review
|
Failed
|
01/17/2025
|
01/07/2025
|
|
|
|
|
|
See Document Markup
Please add "TBD".
[CSWPPP; Page 1 of 32]
|
|
|
See Document Markup
Puyallup River Fecal Coliform TMDL.
[CSWPPP; Page 4 of 32]
|
|
|
See Document Markup
Please complete.
[CSWPPP; Page 28 of 32]
|
|
|
See Document Markup
Per KCook email dated 10/25/24, there was additional gravel added to another area (approx. 24'x114') just north of the curve of the onsite farm road. This area should be included with this permit application.
[Storm Report; Page 8 of 32]
|
|
|
See Document Markup
Adjust quantities for the additional 24'x114' gravelled area (See Page 8 comment).
[Storm Report; Page 9 of 32]
|
|
|
See Document Markup
Adjust quantities for the additional 24'x114' gravelled area (See Page 8 comment).
[Storm Report; Page 10 of 32]
|
|
|
See Document Markup
It does not appear that there are any catch basins associated with this project. Perhaps language such as:
-"Maintain, swales, ditches and culverts at an appropriate frequency to ensure that plugging,erosion, and flooding does not occur."
-"Provide maintenance and cleaning of debris, sediments, and other pollutants from the stormwater collection, conveyance, and treatment systems to maintain proper operation."
-"Reseed bare turf areas until the vegetation fully covers the grond surface."
[Storm Report; Page 12 of 32]
|
|
|
See Document Markup
Provide a brief Construction Sequence per City Standards Section 501.6.
[Plans; Sheet C-01 of 7]
|
|
|
See Document Markup
Callout and show the Williams Gas Easement on the project plan views. (Typ.)
[Plans; Sheet C-01 of 7]
|
|
|
See Document Markup
Provide Pierce County approval acknowledging the project's connection to the direct discharge conveyance system and ultimately the outfall in accordance with the County issued Shoreline Substantial Development permit. (Ref. MHigginson email to JMJ dated 12/17/24).
[Plans; Sheet C-01 of 7]
|
|
|
See Document Markup
Per KCook email dated 10/25/24, there was additional gravel added to this area and should be included with this permit application.
[Plans; Sheet C-02 of 7]
|
|
|
See Document Markup
Revise ROW width per dedication AFN 202005280613.
[Plans; Sheet C-02 of 7]
|
|
|
See Document Markup
Revise ROW width per dedication AFN 202005280613.
[Plans; Sheet C-05 of 7]
|
|
|
See Document Markup
Please add note: "See City Standard Detail 01.02.08a."
[Plans; Sheet C-05 of 7]
|
|
|
See Document Markup
Clarify how upstream ditch flows are conveyed across the access locations. Callout culvert size, length, and IE at inlet and outlet.
[Plans; Sheet C-06 of 7]
|
|
|
See Document Markup
Same comment will apply to the 24x114 gravelled area not shown (see comment on Sht C-02).
[Plans; Sheet C-06 of 7]
|
|
|
See Document Markup
Due to the reverse grade of the existing ditch in this area and the potential to cause flooding of the roadway (and/or the property), regrade the ditch to ensure positive drainage across the limits of the project.
[Plans; Sheet C-06 of 7]
|
|
|
See Document Markup
Please add "min." to the callouts.
[Plans; Sheet C-07 of 7]
|
|
|
See Document Markup
Add City Standard Detail(s):
01.02.08a. //
[Plans; Sheet C-07 of 7]
|
|
|
See Document Markup
Please revise to: "and City Standard Detail 01.02.08a."
[Plans; Sheet C-07 of 7]
|
|
|
See Document Markup
|
|
Public Works Collection Review
|
Approved
|
01/17/2025
|
01/07/2025
|
|
|
|
|
Engineering Civil Review
|
Pending
|
12/08/2025
|
|
|
|
|
|
Fire Review
|
Pending
|
12/08/2025
|
|
|
|
|
|
Planning Review
|
Pending
|
12/08/2025
|
|
|
|
|