CITY OF PUYALLUP PERMITTING PORTAL

Permit Application Status

PRCTI20220873


In order to request inspections, you need to be signed in.

Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PRCTI20220873
Commercial - Tenant Improvement/Remodel
Closed
IDIL PUYALLUP LLC
Alteration/Remodel
Expansion of existing conditioned office and mezzanine TI in existing warehouse building, including new elevator. New break room, restrooms and offices in warehouse area. Incorporation of light manufacturing equipment and processes within warehouse. Envelope upgrades for full conditioning of warehouse space per deferred HVAC Design/Build submittal. Repurposing of existing on-site trailer parking area with auto parking stalls to support new manufacturing use. REVISION (1) - 10/28/2022 REMOVAL OF ONE PRIVATE OFFICE AND ENLARGEMENT OF ANOTHER OFFICE REVISION (2) 11/18/2022 - RECALCULATION AND RELOCATION OF EV CHARGING INFRASTRUCTURE
05/25/2022
08/29/2022
11/17/2023
05/18/2023

Locations

Reviews

Documents Returned For Corrections

Review Type Outcome Est. Completion Date Completed
Building Review Approved 11/28/2022 11/23/2022
Planning Review Approved 11/28/2022 11/22/2022
Engineering Traffic Review VOID 11/28/2022 11/22/2022
Engineering Review Failed 11/28/2022 11/22/2022
Fire Review VOID 11/28/2022 11/18/2022
Fire Review VOID 11/07/2022 11/03/2022
Building Review Approved 11/07/2022 11/03/2022
Planning Review VOID 11/07/2022 10/28/2022
Engineering Traffic Review VOID 11/07/2022 10/28/2022
Engineering Review VOID 11/07/2022 10/28/2022
Building Review Approved 09/04/2022 08/26/2022
Engineering Traffic Review Approved 09/04/2022 08/26/2022
Engineering Review Approved 09/04/2022 08/26/2022
Fire Review Approved 09/04/2022 08/26/2022
Planning Review Approved 09/04/2022 08/25/2022
Engineering Review Approved 08/18/2022 08/16/2022
Building Review Failed 08/18/2022 08/16/2022
Fire Review Approved 08/18/2022 08/15/2022
Planning Review Approved 08/18/2022 08/09/2022
Engineering Traffic Review Approved 08/18/2022 08/08/2022
Planning Review Failed 06/30/2022 07/08/2022
Building Review Failed 06/30/2022 07/08/2022
Engineering Traffic Review Approved 06/30/2022 06/30/2022
Fire Review Approved 07/16/2022 06/30/2022
Fire Review Failed 06/30/2022 06/26/2022
Engineering Review VOID 06/30/2022 06/16/2022

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Review Fee (Commercial Building) $265.00 $265.00 Paid 08/26/2022
Building Permit Fee $8,346.25 $8,346.25 Paid 08/26/2022
Building Plan Review Fee $5,425.06 $5,425.06 Paid 05/26/2022
WA State Building Code Council Fee (Commercial) $25.00 $25.00 Paid 08/26/2022
Traffic Impact Fee (Commercial) $534,150.00 $534,150.00 Paid 08/30/2022
Resubmittal Fee $130.00 $130.00 Paid 08/08/2022
Resubmittal Fee $130.00 $130.00 Paid 08/25/2022
Resubmittal Fee $130.00 $130.00 Paid 11/10/2022
Resubmittal Fee $130.00 $130.00 Paid 11/18/2022
Resubmittal Fee $130.00 $130.00 Paid 01/17/2023
Sewer System Development ChargeFee - Tenant Improvment/Addition $21,704.65 $21,704.65 Paid 01/17/2023
Water System Development ChargeFee - Tenant Improvment/Addition $14,556.42 $14,556.42 Paid 01/17/2023
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Foundation/Rebar Inspection Not Ready 8/30/2022 8/30/2022 08/30/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
08/30/2022
1. Provide city approved plans on site at time of next inspection 2.not ready

Combination Frame And Rough In Inspection Not Ready 8/30/2022 8/30/2022 08/30/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
08/30/2022
1. provide city approved on site at the time of next inspection 2. not ready

Foundation/Rebar Inspection Partial Pass 9/1/2022 9/1/2022 09/01/2022
Monty Johnson ((253) 770-3326)
Other/Miscellaneous
Carried Forward
09/01/2022
1. Provide city approved plans on site at time of next inspection 2.not ready

Other/Miscellaneous
Carried Forward
09/01/2022
concrete progressing with special insp, received ctl report.

Foundation/Rebar Inspection Partial Pass 9/8/2022 9/8/2022 09/08/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
09/08/2022
1. Provide city approved plans on site at time of next inspection 2.not ready

Other/Miscellaneous
Carried Forward
09/08/2022
concrete progressing with special insp, received ctl report.

Foundation/Rebar Inspection Partial Pass 9/15/2022 9/15/2022 09/15/2022
Kevin Spruell ((253) 841-5590)
Other/Miscellaneous
Carried Forward
09/15/2022
1. Provide city approved plans on site at time of next inspection 2.not ready

Other/Miscellaneous
Carried Forward
09/15/2022
concrete progressing with special insp, received ctl report.

Frame Inspection Not Ready 10/27/2022 10/27/2022 10/27/2022
Kevin Spruell ((253) 841-5590)
Shear Wall Inspection Partial Pass 10/27/2022 10/27/2022 10/27/2022
Kevin Spruell ((253) 841-5590)
Exhaust/Vent Fans Inspection Partial Pass 11/1/2022 11/1/2022 11/01/2022
Shannon King ((253) 840-6684)
Combination Frame And Rough In Inspection Failed 11/1/2022 11/1/2022 11/01/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Resolved
11/01/2022
1. provide city approved on site at the time of next inspection 2. not ready

Wallboard / Drywall Inspection Partial Pass 11/4/2022 11/4/2022 11/04/2022
Kevin Spruell ((253) 841-5590)
Shear Wall Inspection Partial Pass 11/4/2022 11/4/2022 11/04/2022
Kevin Spruell ((253) 841-5590)
Combination Frame And Rough In Inspection Partial Pass 11/14/2022 11/14/2022 11/14/2022
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection Partial Pass 11/14/2022 11/14/2022 11/14/2022
Shannon King ((253) 840-6684)
Energy (Insulation) Inspection Partial Pass 11/14/2022 11/14/2022 11/14/2022
Shannon King ((253) 840-6684)
Exhaust/Vent Fans Inspection Partial Pass 11/21/2022 11/21/2022 11/21/2022
Shannon King ((253) 840-6684)
Frame Inspection Partial Pass 11/21/2022 11/21/2022 11/21/2022
Shannon King ((253) 840-6684)
Exhaust/Vent Fans Inspection Partial Pass 11/22/2022 11/22/2022 11/22/2022
Shannon King ((253) 840-6684)
Firewall/Firestop Inspection Not Ready 11/23/2022 11/23/2022 11/23/2022
Kevin Spruell ((253) 841-5590)
Other/Miscellaneous
Carried Forward
11/23/2022
1. called in in error

Energy (Insulation) Inspection Partial Pass 11/23/2022 11/23/2022 11/23/2022
Kevin Spruell ((253) 841-5590)
Combination Frame And Rough In Inspection Failed 11/29/2022 11/29/2022 11/29/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
11/29/2022
1 ; complete draft stop at top plate as discussed with contractor. 2 ; strap top plate at over bored plumbing penetration in top plates. 3 ; seal top of chases as discussed with contractor. 4 ; complete top of wall bracing at 6' o.c. as per City approved plans. 5 ; remove screws at top track to ceiling grid. 6 ; complete plumbing vents to exterior of building as discussed with contractor at 2nd floor. 7 ; inspection of 2nd floor only.

Firewall/Firestop Inspection Failed 11/29/2022 11/29/2022 11/29/2022
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
11/29/2022
1. called in in error

Other/Miscellaneous
Carried Forward
11/29/2022
1 ; complete sealing of penetrations in top plates as discussed with contractor.

Wallboard / Drywall Inspection Partial Pass 11/30/2022 11/30/2022 11/30/2022
Shannon King ((253) 840-6684)
Energy (Insulation) Inspection Partial Pass 12/6/2022 12/6/2022 12/06/2022
Shannon King ((253) 840-6684)
Wallboard / Drywall Inspection Partial Pass 12/13/2022 12/13/2022 12/13/2022
Kevin Spruell ((253) 841-5590)
Exhaust/Vent Fans Inspection Failed 12/29/2022 12/29/2022 12/29/2022
Monty Johnson ((253) 770-3326)
Other/Miscellaneous
Carried Forward
12/29/2022
complete seismic bracing, complete diffuser attachment

Ceiling Grid/T-Bar Inspection Failed 12/29/2022 12/29/2022 12/29/2022
Monty Johnson ((253) 770-3326)
Other/Miscellaneous
Carried Forward
12/29/2022
1:complete berk clip positive attachment at 2 sides as discussed 2:install siezmic pods 3:attach diffusers as required for over 10 LB

Exhaust/Vent Fans Inspection Partial Pass 1/10/2023 1/10/2023 01/10/2023
Shannon King ((253) 840-6684)
Ceiling Grid/T-Bar Inspection Failed 1/10/2023 1/10/2023 01/10/2023
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
01/11/2023
1 ; complete lateral force bracing at ceilings of warehouse break room,1st and 2nd floor office space as per City approved plans. 2 ; complete perimeter supporting clips (BERC clips) as per install instructions at warehouse break room and 1st and 2nd floor office spaces. 3 ; complete marking and identification of fire rated walls prior to ceiling grid cover inspection. 4 ; seal all penetrations in fire rated walls prior to ceiling grid inspection. 5 ; complete rough-in of mechanical at 2nd floor of office space. not ready

Ceiling Grid/T-Bar Inspection Passed w/ Conditions 1/12/2023 1/12/2023 01/12/2023
Shannon King ((253) 840-6684)
Other/Miscellaneous
Outstanding
01/11/2023
1 ; complete lateral force bracing at ceilings of warehouse break room,1st and 2nd floor office space as per City approved plans. 2 ; complete perimeter supporting clips (BERC clips) as per install instructions at warehouse break room and 1st and 2nd floor office spaces. 3 ; complete marking and identification of fire rated walls prior to ceiling grid cover inspection. 4 ; seal all penetrations in fire rated walls prior to ceiling grid inspection. 5 ; complete rough-in of mechanical at 2nd floor of office space. not ready

Exit Lighting Test Inspection Failed 1/18/2023 01/18/2023
David Drake ((253) 864-4171)
Exit Light Test
Carried Forward
01/18/2023
o Warehouse space, staff lounge Turn both Exit Signs 90 degrees so there visible o Warehouse space, staff lounge both Exit signs not working o Warehouse space, restrooms are required to have emergency lighting at 300sqft, bathrooms calc out at 328sqft o Warehouse space, between staff lounge and bathrooms – Exit sign is now in an alcove and needs to be moved outside this area for visibility o Main office space, Exit sign outside first floor bathrooms need to be dropped down below the ceiling beam that block it o Main office space, install Exit sign per plan first floor eastside of building o Main office space, install Exit sign per plan second floor middle stairs o All spaces, aim spot lights on Exit signs so they illuminate at floor level o Warehouse space failed o Main Office space failed

Fire Final Inspection Not Ready 1/18/2023 1/18/2023 01/18/2023
David Drake ((253) 864-4171)
Fire Or Smoke Damper Inspection VOID 01/18/2023
David Drake ((253) 864-4171)
Hydrostatic Test 200Lbs 2Hrs VOID 01/18/2023
David Drake ((253) 864-4171)
Comment Building Div Inspection Partial Pass 1/20/2023 01/19/2023
Ray Cockerham ((253) 841-5585)
Comment Building Div Inspection Partial Pass 1/10/2023 01/19/2023
Ray Cockerham ((253) 841-5585)
Fire Final Inspection Partial Pass 1/19/2023 01/19/2023
David Drake ((253) 864-4171)
Other/Miscellaneous
Outstanding
01/19/2023
1. Fire Alarm approved, Elevator device not tested or elevator. TCO approval for fire excluding elevator 2. Fire Sprinkler approved 3. Radio test approved 4. Exit Light test approved 5. Exit signs approved 6. Second floor new area to be blocked off until elevator is installed and approved 7. TCO has fire approval, no occupancy on second floor in new area. 8. Pending Building approval for TCO

Building Final Inspection Failed 1/20/2023 1/20/2023 01/20/2023
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
01/23/2023
1 ; complete construction barrier at 2nd floor prior to building final as discussed with contractor, 2 ; provide engineering final prior to building final inspection. 3 ; complete accessible restroom signage. 4 ; complete no storage allowed roof signage at break room & bathrooms as per plans. 5 ; complete E.V. parking and charging stations as city approved plans. 6 ; provide access to roof to inspect. 7 ; complete install of elevator and elevator final prior to building final. 8 ; inspection of t.c.o. only for office, breakroom,& warehouse restrooms only. not ready

Comment Engineering Div Inspection VOID 01/23/2023
Jeff Hill ((253) 204-5633)
Cover Inspection/Thrust Blocks Inspection VOID 01/23/2023
Jeff Hill ((253) 204-5633)
Engineering Final Inspection Partial Pass 01/23/2023
Jeff Hill ((253) 204-5633)
Frame Inspection VOID 1/23/2023 1/23/2023 01/23/2023
Shannon King ((253) 840-6684)
Building Final Inspection Partial Pass 1/23/2023 1/23/2023 01/23/2023
Shannon King ((253) 840-6684)
Other/Miscellaneous
Carried Forward
05/02/2023
1 ; all temp. walls at 2nd floor to remain in place until elevator final approval. 2 ; complete all outstanding corrections from previous build final list for t.c.o of warehouse break room, warehouse restrooms,1st & half of 2nd floor offices. 3 ; call for full building final when complete. 4 ; t.c.o. approved for warehouse break room, warehouse restrooms,1st & half of 2nd floor offices for 30 days from 1/23/2022

Fire Final Inspection VOID 05/01/2023
David Drake ((253) 864-4171)
Building Final Inspection Partial Pass 5/2/2023 5/2/2023 05/02/2023
Shannon King ((253) 840-6684)
Other/Miscellaneous
Resolved
05/02/2023
1 ; complete construction barrier at 2nd floor prior to building final as discussed with contractor, 2 ; provide engineering final prior to building final inspection. 3 ; complete accessible restroom signage. 4 ; complete no storage allowed roof signage at break room & bathrooms as per plans. 5 ; complete E.V. parking and charging stations as city approved plans. 6 ; provide access to roof to inspect. 7 ; complete install of elevator and elevator final prior to building final. 8 ; inspection of t.c.o. only for office, breakroom,& warehouse restrooms only. not ready

Other/Miscellaneous
Outstanding
05/02/2023
1 ; complete no storage allowed roof signage at break room and bathroom as discussed with contractor. 2 ;provide City approved plans for E.V. parking/charging station at time of inspection. 3 ; completer insulation at floor joist at 2nd floor outside of 1st floor restrooms. 4 ; protect insulation at refrigeration line set from U.V. rays and seal doghouses as discussed with contractor.

Building Final Inspection Passed w/ Conditions 5/18/2023 5/18/2023 05/18/2023
Shannon King ((253) 840-6684)
Other/Miscellaneous
Resolved
05/18/2023
1 ; all temp. walls at 2nd floor to remain in place until elevator final approval. 2 ; complete all outstanding corrections from previous build final list for t.c.o of warehouse break room, warehouse restrooms,1st & half of 2nd floor offices. 3 ; call for full building final when complete. 4 ; t.c.o. approved for warehouse break room, warehouse restrooms,1st & half of 2nd floor offices for 30 days from 1/23/2022

Footing/Setback Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Underfloor Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Slab/Insulation Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Block Wall Rebar Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Roof Sheathing Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Refrigeration Line Test Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Hydronic Piping Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Re-Roof Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Exhaust Hood Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Light Test For Grease Duct Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Racking Anchors/Signage Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Medical Gas Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Plumbing Rough In Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Electric Vehicle Charging Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Foundation/Rebar Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Other/Miscellaneous
Outstanding
09/15/2022
1. Provide city approved plans on site at time of next inspection 2.not ready

Other/Miscellaneous
Outstanding
09/15/2022
concrete progressing with special insp, received ctl report.

Shear Wall Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Energy (Insulation) Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Combination Frame And Rough In Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Other/Miscellaneous
Outstanding
11/29/2022
1 ; complete draft stop at top plate as discussed with contractor. 2 ; strap top plate at over bored plumbing penetration in top plates. 3 ; seal top of chases as discussed with contractor. 4 ; complete top of wall bracing at 6' o.c. as per City approved plans. 5 ; remove screws at top track to ceiling grid. 6 ; complete plumbing vents to exterior of building as discussed with contractor at 2nd floor. 7 ; inspection of 2nd floor only.

Wallboard / Drywall Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Comment Building Div Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)
Comment Building Div Inspection VOID 05/18/2023
Shannon King ((253) 840-6684)

Conditions

Condition Status Department Category Expiration Date Due Date
Building Permit Standard Conditions Open Standard Conditions
: * Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
Fire Review Conditions Open Standard Conditions
: FIRE NOTES: Separate Permits are required for Fire Alarm and Automatic Fire Sprinklers. Fire alarm systems designed per TOTAL coverage provision of the NFPA standard and 3rd Party Certification is required (UL or other). This is a limited scope review, limited to the work areas designated on the submitted plans. Separate permits are required for rack storage systems, equipment, and specialized ventilation systems. 1. INSTALL ADDRESS NUMBERS PER THE FOLLOWING DISTANCES:0-50FOOT SETBACK FROM STREET NUMBERS SHALL BE 6 INCHES IN HEIGHT; 51-100 FEET 12 INCHES IN HEIGHT. ALL NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDITIONAL NUMBERS MAY BE NEEDED AT DRIVEWAY ENTRANCE IF BUILDING NUMBERS ARE NOT VISIBLE FROM THE STREET. REAR DOORS OF SUITES OR UNITS SHALL ALSO BE LABELED WITH MINIMUM 4 INCH NUMBERS. 2. FIRE HYDRANTS REQUIRED FOR CONSTRUCTION AND FIRE DEPARTMENT ACCESS SHALL BE INSTALLED AND APPROVED BY THE FIRE CODE OFFICIAL PRIOR TO THE STORAGE OR INSTALLATION OF ANY COMBUSTIBLE FRAMING MATERIAL. ACCESS ROADWAY SURFACES SHALL BE DESIGNED TO CITY STANDARDS AND BE DESIGNED TO MAINTAIN THE IMPOSED LOADS OF A 80,000 POUND FIRE APPARATUS. ASPHALT TREATED BASE, ASPHALT OR CONCRETE PAVEMENT CAN BE USED TO PROVIDE THE REQUIRED ALL-WEATHER DRIVING SURFACE. 3. ANY REQUIRED FIRE LANE MARKINGS SHALL BE INSTALLED PRIOR TO FINAL INSPECTION AND PER CITY ORDINANCE. 4. KNOX BOXES, WHEN REQUIRED, SHALL BE INSTALLED USUALLY TO THE RIGHT OF THE MAIN FRONT DOOR AND NO HIGHER THAN 6 FEET OFF OF THE GROUND. ONLY HINGED KNOX BOXES SHALL BE USED. KNOX BOXES AND KEY SWITCHES CAN BE ORDERED ONLINE AT THE "KNOX COMPANY" 5. FIRE EXTINGUISHERS WILL BE REQUIRED PER CHAPTER 9 OF THE INTERNATIONAL FIRE CODE. GENERALLY, 1 FIRE EXTINGUISHER WITH A MINIMUM RATING OF 2A 10BC SHALL BE INSTALLED PER EVERY 3,000 SQUARE FEET OF FLOOR AREA. THE LOCATION OF THE FIRE EXTINGUISHERS SHALL BE NEAR THE EXIT DOORS AND TRAVEL DISTANCE TO AN EXTINGUISHER SHALL NOT EXCEED 75 FEET. ADDITIONAL SIGNAGE MAY BE NECESSARY TO INDICATE THE FIRE EXTINGUISHER LOCATION.
Miscellaneous Condition Resolved Engineering Division Prior to Completion
: The Engineering Review is approved with the exception of the parking lot work and new outdoor staircase. This work shall not be authorized until the associated Plan Change Request (#7) is approved.
Miscellaneous Condition Resolved Engineering Division Prior to Occupancy
: Water and sewer system development charges shall be paid prior to occupancy as was discussed during the meeting on January 11, 2023 at 8:45AM. [Yianni Charitou @ 01/11/2023 9:56 AM] SDC fees paid 1/17/2023 - RESOLVING CONDITION - JK

Related Permit & Planning Applications

Reference Number Status Type
PRRWF20220381 Canceled Retaining Wall
PRFS20221095 Closed Fire Sprinklers
PRSG20221172 Closed Sign/Awning
PRFA20221284 Closed Fire Alarms
PRCTI20221624 Closed Commercial - Tenant Improvement/Remodel
PRCTI20221709 Closed Commercial - Tenant Improvement/Remodel
PRCTI20221916 Closed Commercial - Tenant Improvement/Remodel
PRFA20230034 Closed Fire Alarms
PRCTI20230167 Closed Commercial - Tenant Improvement/Remodel
PRFA20230302 Closed Fire Alarms
PRCTI20230447 Closed Commercial - Tenant Improvement/Remodel
PRCP20230511 Closed Carport
PRFS20230711 Closed Fire Sprinklers
PRCP20230996 Closed Carport
PRCTI20230997 Closed Commercial - Tenant Improvement/Remodel
PRMH20231156 Closed Mechanical - COMMERCIAL ONLY
PRFS20231516 Closed Fire Sprinklers
PRFS20240612 Closed Fire Sprinklers
PRCTI20240671 Closed Commercial - Tenant Improvement/Remodel
PRCCP20241039 Returned for Correction Civil Construction Permit

Documents & Images

Date Uploaded File Type Name
01/10/2023 Report Inspection Report (Exhaust/Vent Fans Inspection)
01/11/2023 Form Red Dot TI - Plumbing Fixture Worksheet (Stamped)
01/17/2023 Receipt Receipt for transaction:2023-000085
05/02/2023 Report Inspection Report (Building Final Inspection)
05/02/2023 Report Inspection Report (Engineering Final Inspection)
05/18/2023 Report Inspection Report (Building Final Inspection)
05/26/2022 Receipt Receipt for transaction:2022-000990
08/08/2022 Receipt Receipt for transaction:2022-001533
08/25/2022 Receipt Receipt for transaction:2022-001674
08/26/2022 Receipt Receipt for transaction:2022-001685
08/26/2022 Form Red Dot TI - 2018 WSEC Mechanical Compliance Summary form (Stamped)
08/26/2022 Plans RED DOT TI - 2nd Permit Resubmittal Set 20220824 (Stamped)
08/26/2022 Plans Red Dot TI - Landscape Permit Resubmittal (Stamped)
08/26/2022 Form Red Dot TI - Lighting Summary (Stamped)
08/26/2022 Plans Red Dot TI - Plumbing Permit Drawings (Stamped)
08/26/2022 Form Red Dot TI - Revised Energy Calculations 22-0715 (Stamped)
08/26/2022 Report Red Dot TI - Structural Calculations 22-0420 (Stamped)
08/26/2022 Report Red Dot TI - VRF Support Calculation Docs (Stamped)
08/29/2022 Permit Permit - Detailed
08/29/2022 Letter Permit Job Card
08/29/2022 Plans Red Dot TI - HVAC Drawings V3 (Flattened) (Stamped)
08/30/2022 Report Inspection Report (Combination Frame And Rough In Inspection)
08/30/2022 Report Inspection Report (Foundation/Rebar Inspection)
08/30/2022 Receipt Receipt for transaction: 2022-001708
08/30/2022 Plans Red Dot TI - Architectural Permit Comments Set V2 (Stamped)
09/08/2022 Report Inspection Report (Foundation/Rebar Inspection)
10/27/2022 Report Inspection Report (Frame Inspection)
10/27/2022 Report Inspection Report (Shear Wall Inspection)
11/01/2022 Report Inspection Report (Combination Frame And Rough In Inspection)
11/01/2022 Report Inspection Report (Exhaust/Vent Fans Inspection)
11/04/2022 Report Inspection Report (Shear Wall Inspection)
11/04/2022 Report Inspection Report (Wallboard / Drywall Inspection)
11/10/2022 Receipt Receipt for transaction:2022-002240
11/10/2022 Plans Red Dot Office TI - Building Resubmit Form (Flattened)
11/10/2022 Plans Red Dot Office TI - Post-Permit Revision 22-1026 (Stamped)
11/14/2022 Report Inspection Report (Combination Frame And Rough In Inspection)
11/14/2022 Report Inspection Report (Energy (Insulation) Inspection)
11/14/2022 Report Inspection Report (Wallboard / Drywall Inspection)
11/18/2022 Receipt Receipt for transaction:2022-002312
11/21/2022 Report Inspection Report (Exhaust/Vent Fans Inspection)
11/22/2022 Report Inspection Report (Exhaust/Vent Fans Inspection)
11/23/2022 Report Inspection Report (Energy (Insulation) Inspection)
11/23/2022 Report Inspection Report (Firewall/Firestop Inspection)
11/23/2022 Letter Permit Review Comment Notice
11/23/2022 Plans Red Dot Office TI - Site Plan EV Revisions 22-1110 (Flattened)
11/29/2022 Report Inspection Report (Combination Frame And Rough In Inspection)
11/29/2022 Report Inspection Report (Firewall/Firestop Inspection)
11/29/2022 Report Inspection Report (Frame Inspection)
11/30/2022 Report Inspection Report (Wallboard / Drywall Inspection)
12/06/2022 Report Inspection Report (Energy (Insulation) Inspection)
12/06/2022 Report Inspection Report (Firewall/Firestop Inspection)
12/13/2022 Report Inspection Report (Wallboard / Drywall Inspection)


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.