Summary

PRFS20241715
Fire Sprinklers
Closed
PUGET SOUND ENERGY/GAS
New
Install new fire sprinkler system at PSE Operations Training Facility including fire pump, wet system, dry system, and preaction system. Building is single story with steel joists and beams.
11/05/2024
12/17/2024
01/03/2026
07/07/2025

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
12/17/2024 FIRE SPRINKER PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 12/06/2024 12/13/2024

Fees

Paid Fees Amount Paid Owing Date Paid
Automatic Fire-Extinguishing System (New) Permit Fee $1,895.35 $1,895.35 Paid 12/17/2024
Automatic Fire-Extinguishing System (New) Plan Review Fee $1,231.98 $1,231.98 Paid 11/05/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Hydrostatic Test 200Lbs 2Hrs Passed 1/10/2025 1/13/2025 01/13/2025
David Drake ((253) 864-4171)
Fire Sprinkler Cover Inspection Partial Pass 2/10/2025 2/10/2025 02/12/2025
David Drake ((253) 864-4171)
Fire Sprinkler Cover Inspection Partial Pass 2/13/2025 2/13/2025 02/13/2025
David Drake ((253) 864-4171)
Fire Sprinkler Cover Inspection Passed 4/15/2025 4/15/2025 04/15/2025
David Drake ((253) 864-4171)
Fire Sprinkler Final Inspection Partial Pass 4/30/2025 4/30/2025 05/01/2025
David Drake ((253) 864-4171)
Fire Sprinkler Dry System Trip Test Passed 7/1/2025 7/1/2025 07/07/2025
David Drake ((253) 864-4171)
Fire Sprinkler Final Inspection Passed 7/1/2025 7/1/2025 07/07/2025
David Drake ((253) 864-4171)

Conditions

Condition Status Category
Fire Sprinkler System (New) Conditions Open Standard Conditions
• Provide plans and permit on site for inspection. • Cover and final inspections are required. • Fire watch is required when sprinkler system is out of service in existing buildings. • Contractor required at all inspections. • Hydro test will be required on all new and existing buildings. Appointment required. • Hydro test, two inspections will be required 2hrs apart. Call to schedule times. Am/pm is not guaranteed without appointment. • Fire pumps will be required to be tested and witnessed by inspector. • Tool kit required at time of final. • NFPA placards required. • Due to unforeseeable construction design, all head locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first. David Drake ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
E-19-0538 Closed Clear, Fill, & Grade Permit
PRAMR20231722 Closed Alternative Methods / Materials Request
PRCNC20231747 Canceled Commercial - New Construction
PRCCP20240215 Closed Civil Construction Permit
PRCNC20240216 Closed Commercial - New Construction
PRGR20240391 Closed Clear, Fill, & Grade Permit
PRCNC20241049 Closed Commercial - New Construction
PRCNC20241050 Closed Commercial - New Construction
PRCNC20241051 Closed Commercial - New Construction
PRCNC20241052 Closed Commercial - New Construction
PRFN20241253 Closed Fence
PRCNC20241576 Closed Commercial - New Construction
PRFA20241983 Closed Fire Alarms
PRAMR20250001 Closed Alternative Methods / Materials Request
PRSOL20250112 Closed Solar Panel Permit
PRAMR20250344 Closed Alternative Methods / Materials Request
PRSG20250392 Closed Sign/Awning
PRCTI20250486 Closed Commercial - Tenant Improvement/Remodel
PRCTI20250781 Closed Commercial - Tenant Improvement/Remodel
PRMH20260004 Closed Mechanical - COMMERCIAL ONLY
PLPRE20220160 File Closed Pre-Application
PLLC20230017 File Closed Lot Combination
PLPSP20230096 File Closed Preliminary Site Plan

Documents & Images

Date Uploaded File Type Name
11/05/2024 Plans FLOOR PLAN
11/05/2024 Plans HYDRAULIC CALC'S
11/05/2024 Form APPLICATION FORM
11/05/2024 Plans SEISMIC CALC'S
11/05/2024 Other FIRE PUMP CUT SHEETS
11/05/2024 Receipt Receipt for transaction:2024-002298
12/17/2024 Plans Patriot - PSE-OTC Equipment Submittal All (Flattened)
12/17/2024 Plans FIRE SPRINKER PLANS (Stamped)
12/17/2024 Letter Permit - Detailed
12/17/2024 Receipt Receipt for transaction:2024-002613


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.