Summary

PRCTI20250486
Commercial - Tenant Improvement/Remodel
Closed
INSTALLATION OF CONCRETE PAD FOR SUPPORT OF GENERATOR, INCLUDING FUEL TANK & ENCLOSURE ~ PSE TRAINING CENTER
04/11/2025
05/13/2025
01/06/2026
07/10/2025

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Engineering Review Approved 05/21/2025 05/12/2025
Engineering Traffic Review VOID 05/21/2025 05/07/2025
Fire Review Approved 05/21/2025 05/06/2025
Planning Review Approved 05/21/2025 05/05/2025
Design Review VOID 05/21/2025 05/01/2025
Building Review Approved 05/21/2025 05/01/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Building Permit Fee $1,604.15 $1,604.15 Paid 05/13/2025
Building Plan Review Fee $1,042.70 $1,042.70 Paid 05/13/2025
WA State Building Code Council Fee (Commercial) $25.00 $25.00 Paid 05/13/2025
Fire Review Fee (Commercial Building) $265.00 $265.00 Paid 05/13/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Comment Engineering Div Inspection Passed 07/10/2025
Jeff Hill ((253) 204-5633)
Hydrostatic Test 200Lbs 2Hrs Passed 07/10/2025
Jeff Hill ((253) 204-5633)
Engineering Final Inspection Passed 07/10/2025
Jeff Hill ((253) 204-5633)
Building Final Inspection Passed 7/3/2025 7/10/2025 07/10/2025
Monty Johnson ((253) 770-3326)
Comment Building Div Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Footing/Setback Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Foundation/Rebar Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Slab/Insulation Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Roof Sheathing Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Shear Wall Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Firewall/Firestop Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Energy (Insulation) Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Frame Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Combination Frame And Rough In Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Ceiling Grid/T-Bar Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Wallboard / Drywall Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Exit Lighting Test Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Hydronic Piping Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Gas Test Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Refrigeration Line Test Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Exhaust Hood Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Light Test For Grease Duct Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Exhaust/Vent Fans Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Medical Gas Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Fire Or Smoke Damper Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Emergency Radio Test Review Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Planning Final Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Fire Final Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)
Mechanical Final Inspection VOID 07/17/2025
Joyce Kennedy ((253) 841-5405)

Conditions

Condition Status Category
Building Permit Standard Conditions Open Standard Conditions
Building Division
* Final approval by the Building Official is required prior to use or occupancy.* Work shall not proceed until the inspector has approved the stages of construction.* Surface storm water shall be diverted from the building site and shall not drain onto adjacent properties.* I hereby acknowledge that I have read this Permit/Application, that the information given is correct; that I am the owner or the duly authorized agent of the owner; that plans submitted herewith are in compliance with all applicable city, county and state laws and that all construction will proceed in accordance with said laws. This permit shall expire if work is not commenced with 180 days or if the work is suspended for a period of 180 days. Permits expire two years from issuance. * By leaving the contractor information section blank, I hereby certify further that contractors (general or subcontractors) will not be hired to perform any work in association with this permit. I also certify that if I do choose to hire a contractor (general or subcontractor) I will only hire those contractors that are licensed by the State of Washington. If you are a property owner, contractor or permittee and you are paying for someone to perform the work, they must have a valid contractor registration and the person(s) installing plumbing inside a structure must meet the plumbing certification requirements. If you have any questions regarding these regulations, you may contact the Washington State Department of Labor and Industries or you can find more information on-line at: http://www.lni.wa.gov/TradesLicensing/Contractors/HireCon/default.asp
Fire Review Conditions Open Standard Conditions
1. Provide Generator commissioning report prior to Fire Final. 2. Building shutdown with Generator transfer will be required as part of Final. 3. All electronic gates will be required to run off the Generator unless battery backup is provided. 4. L&i Final required prior to City inspections.

Related Permit & Planning Applications

Reference Number Status Type
E-19-0538 Closed Clear, Fill, & Grade Permit
PRAMR20231722 Closed Alternative Methods / Materials Request
PRCNC20231747 Canceled Commercial - New Construction
PRCCP20240215 Closed Civil Construction Permit
PRCNC20240216 Closed Commercial - New Construction
PRGR20240391 Closed Clear, Fill, & Grade Permit
PRCNC20241049 Closed Commercial - New Construction
PRCNC20241050 Closed Commercial - New Construction
PRCNC20241051 Closed Commercial - New Construction
PRCNC20241052 Closed Commercial - New Construction
PRFN20241253 Closed Fence
PRCNC20241576 Closed Commercial - New Construction
PRFS20241715 Closed Fire Sprinklers
PRFA20241983 Closed Fire Alarms
PRAMR20250001 Closed Alternative Methods / Materials Request
PRSOL20250112 Closed Solar Panel Permit
PRAMR20250344 Closed Alternative Methods / Materials Request
PRSG20250392 Closed Sign/Awning
PRCTI20250781 Closed Commercial - Tenant Improvement/Remodel
PRMH20260004 Closed Mechanical - COMMERCIAL ONLY
PLPRE20220160 File Closed Pre-Application
PLLC20230017 File Closed Lot Combination
PLPSP20230096 File Closed Preliminary Site Plan

Documents & Images

Date Uploaded File Type Name
05/13/2025 Plans GENERATOR FOUNDATION PLANS (Stamped)
05/13/2025 Plans GENERATOR SPECS (Stamped)
05/13/2025 Plans VEHICLE IMPACT PROTECTION IF LOCATED IN PARKING LOT – (not in parking lot, see drawings C3.12 and C1.5A) (Stamped)
05/13/2025 Report 0486 CALCS (Stamped)
05/13/2025 Other NARRATIVE FROM PROJECT ARCHITECT (Stamped)
05/13/2025 Plans OVERALL SITE PLAN (Stamped)
05/13/2025 Letter Permit - Detailed
05/13/2025 Receipt Receipt for transaction:2025-000933
05/13/2025 Letter Permit Job Card