CITY OF PUYALLUP PERMITTING PORTAL

Planning Application Status

P-21-0130




Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

P-21-0130
All Saints Church Food Warehouse
Conditional Use Permit
Conditional Use Permit
Canceled
10/28/2021
CORP OF CATHOLIC ARCHBISHOP
FOOD WAREHOUSE ~ ALL SAINTS CATHOLIC CHURCH

Locations

Reviews

Review Type Outcome Est. Completion Date Completed
Planning Review Revisions Required 08/13/2022 09/12/2022
Engineering Traffic Review Revisions Required 08/13/2022 09/07/2022
Engineering Review Revisions Required 08/13/2022 08/17/2022
Building Review No Comments 08/13/2022 08/09/2022
Fire Review VOID 08/13/2022 07/21/2022
Engineering Traffic Review Revisions Required 12/23/2021 02/02/2022
Fire Review No Comments 12/23/2021 12/21/2021
Fire Review Revisions Required 12/23/2021 12/15/2021
Engineering Review Revisions Required 12/23/2021 12/15/2021

Fees

Paid Fees Amount Paid Owing Date Paid
None $0.00 $0.00 $0.00
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Application(s) will not be processed until outstanding fees have been paid in full.

$0.00

Meetings

There are no hearings for this planning application.

Conditions

Condition Status Department Category Expiration Date Due Date
Miscellaneous Condition Open Development & Permitting Services
:
Miscellaneous Condition Open Engineering Division Submit With Building Permit Application
: Traffic Impact fees (TIF) will be assessed in accordance with fees adopted by ordinance, per PMC 21.10. Impact fees are subject to change and are adopted by ordinance. The applicant shall pay the proportionate impact fees adopted at the time of building permit application Per Puyallup Municipal Code Section 11.08.135, the applicant/owner would be expected to construct half-street improvements including curb, gutter, planter strip, sidewalk, roadway base, pavement. Any existing improvements which are damaged now or during construction, or which do not meet current City Standards, shall be replaced. Site access driveway shall meet our minimum commercial driveway width requirements (30ft)
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: In the previous review last year, the client was instructed to change the stormwater design and all references in the report and plans from 2019 Storm Water Management Manual to the 2012 SWMMWW with the 2014 updates (2014 SWMMWW) as we were still reviewing under that manual. Soon after that the city began making preparations to switch to the new 2019 manual. The city has now transitioned to the new manual, and we are going to have to request that references and designs now adhere to the 2019 version. We are not able to grant leniency or an exception as the law stipulates that only permitted projects are vested. I do apologize for any inconvenience, and we do not believe that this should change the design or construction costs, although there is work involved with updating the refences and checking for compliance under the new manual. The time that has elapsed since the previous submittal has made this a necessary request. Many of the references in the report actually still reference the 2019 report (Page 2, I-3.4.6 and I-3.4.7 are examples), so not all references need to be changed back. Ensure that the report and plans are consistent, and all references are to the new manual for the Civil Submittal.
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Include Appendix B1 and B2 of the Drainage Report in civil submittal.
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Correct infeasability criteria language. There is enough area for infiltration facilities on the property. Page 2, Drainage Report.
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Demonstrate during civil review with stormwater modeling results that the TDA through a combination of effective hard surfaces and converted vegetation areas does not cause a 0.15 cubic foot per second or greater increase in the 100 year flow frequency per I-3.4.7 in order to claim flow control exempt status.
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Submit Operations and Maintenance Manual for review under Civil Permit submittal.
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Section 10, Part a. Downstream Analysis still describes sheet flow to the road and alley. Correct section with most current design description.
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Drainage Report, Page 5, Table 2 - Existing and proposed areas do not match. Should 'forested' be a part of the Proposed Areas? Revise for Civil Submittal.
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Vicinity Map shall be a minimum of 1 inch equals 1000 feet with an area of approximately 1 square mile shown. Refer to City of Puyallup Design Standards 2.1.10. Appendix A Drainage Report
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Provide CSWPPP with civil submittal
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Provide Geotech Report with Civil Submittal
Miscellaneous Condition Open Engineering Division Standard Conditions
: During civil review, the existing frontage will be evaluated by City Inspectors. Any existing frontage improvements which are substandard by City Standards, currently damaged or damaged during construction shall be replaced by the developer.
Miscellaneous Condition Open Engineering Division Standard Conditions
: In the event that during civil design, there is insufficient room for proposed stormwater facilities in the area(s) shown on the site plan, the stormwater area(s) shall be increased as necessary so the final design will be in compliance with current City Standards. This may result in the number of lots or structures being reduced, or a reduction in other site amenities. [PMC 21.10.060(4), 21.10.150]
Miscellaneous Condition Open Engineering Division Submit With Civil Permit Application
: Each sheet of the civil plans shall have the City of Puyallup Development Engineering approval block located adjacent to the design engineer’s title block and each sheet of the WATER plans shall have the City of Puyallup Fire Code Official’s approval block next to the engineer’s approval block.

Related Permit & Planning Applications

Reference Number Status Type
P-21-0001 File Closed Pre-Application

Documents & Images