Summary

PLCUV20240004
320 Todd Road NE
CUP With Variance
CUP With Variance
Waiting for Conditions
01/09/2024
ERNEST J. FERNANDEZ
Conditional use permit application for the conversion of an existing single-family residence to a professional office in the RM-20 zone and includes a 900sf addition to the rear of the structure. Existing garage on site will remain. This project also includes a variance application to reduce the required side yard landscaping requirements due to the proximity to an exisitng critical area buffer. No structures are proposed within the reduced landscape area. Project will include landscaping, storm water controls, utilities, and other site improvements as required.

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
08/28/2024 Exhibit 13 - Preliminary Storm Report
Review Type Outcome Est. Completion Date Completed
Engineering Review No Comments 06/26/2025 06/12/2025
External Agency Review No Comments 06/26/2025 06/10/2025
Planning Review No Comments 06/26/2025 06/04/2025
Engineering Traffic Review No Comments 06/26/2025 05/30/2025
Fire Review No Comments 06/26/2025 05/29/2025
Building Review No Comments 06/26/2025 05/23/2025
Planning Review Comments 04/30/2025 04/30/2025
External Agency Review Comments 04/30/2025 04/30/2025
Engineering Review No Comments 04/30/2025 04/17/2025
Engineering Traffic Review No Comments 04/30/2025 04/10/2025
Building Review No Comments 04/30/2025 03/28/2025
Fire Review No Comments 04/30/2025 03/24/2025
Engineering Review No Comments 12/23/2024 11/20/2024
Engineering Traffic Review No Comments 12/23/2024 11/20/2024
Planning Review Comments 12/23/2024 11/20/2024
External Agency Review Comments 12/23/2024 11/20/2024
Fire Review No Comments 12/23/2024 11/12/2024
Building Review No Comments 12/23/2024 11/08/2024
Engineering Review No Comments 08/26/2024 08/27/2024
Planning Review Comments 08/26/2024 08/27/2024
External Agency Review Comments 08/26/2024 08/19/2024
Building Review No Comments 08/26/2024 08/14/2024
Engineering Traffic Review No Comments 08/26/2024 07/16/2024
Fire Review No Comments 08/26/2024 07/16/2024
Engineering Review Comments 03/15/2024 03/13/2024
Building Review Comments 03/15/2024 03/13/2024
Planning Review Comments 03/15/2024 03/13/2024
Engineering Traffic Review Comments 03/15/2024 03/08/2024
Fire Review No Comments 03/15/2024 03/06/2024
External Agency Review Comments 03/15/2024 03/06/2024

Fees

Paid Fees Amount Paid Owing Date Paid
CUP/Variance Fee $1,265.00 $1,265.00 Paid 01/09/2024
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Application(s) will not be processed until outstanding fees have been paid in full.

$0.00

Meetings

Title Location Date Time
PLCUV20240004 - Public Hearing Council Chambers, City Hall, 333 S. Meridian 07/09/2025 10:00 AM
Pending
Pending

Conditions

Condition Status Category
Sign Posted On Site Resolved Public Noticing
Planning Division
Public notice sign must be posted on site in a publically visible location.
Signed Affidavit Resolved Public Noticing
Planning Division
Signed Affidavit must be provided.
Miscellaneous Planning Condition Open
Planning Division
Include elevations of trash and recycling receptacle screening as part of building permit application. See PMC 20.25.040 (8) for standards for trash and recycling screening.
Miscellaneous Planning Condition Open
Planning Division
If any fences are proposed, they will need to meet PMC 20.25.040 (5) - Fences & Walls standards. If fencing is proposed, please show on final landscape plan with utility overlay as part of the civil application and include proposed height, material, etc. Please note a building permit is required for a fence if it exceeds 8-feet.
Miscellaneous Planning Condition Open
Planning Division
Sight distance requirements will need to be met on the final landscape plan set submitted with the civil permit application. Please ensure that all plantings along Todd Rd NE are meeting PMC 20.25.040 (10). Sight distance triangle will be required on the final landscape plan w/utility overlay for civil application.
Miscellaneous Planning Condition Open
Planning Division
Please show any proposed exterior mechanical equipment on plan sets as part of the civil application. They will need to meet PMC 20.25.040 (11) standards for exterior mechanical equipment. Fences greater than 8-feet will require a building permit.
Miscellaneous Planning Condition Open
Planning Division
If any outdoor lighting is proposed, it will be required to meet the code section PMC 20.25.040 (19). Please include proposed lighting as part of the civil application and include any lighting attached to the structure on the building permit application elevations.
Miscellaneous Condition Open Submit With Civil Permit Application
Development & Permitting Services
For civil submittal provide profile of the storm system with all elevations in order to evaluate the different types of on site BMPs in relation to each other and other existing and proposed site elements. Include which areas are to be pervious hard surface. The Stormwater Plan is still reporting that pervious hard surfaces will be installed. Make all design elements consistent across all documents. In addition, for civil submittal include the following: contours, existing and proposed; revision to silt fence encompassing all areas of excavation and pavement installation; city standard details for every design element included on plans; and relevant city notes (storm, street, etc.). See City of Puyallup Design Standards Sections 1.0 and 2.0.
Miscellaneous Condition Open Submit With Civil Permit Application
Development & Permitting Services
Public right-of-way runoff shall be detained and treated independently from proposed private stormwater facilities. This shall be accomplished by providing separate publicly maintained storm facilities within a tract or dedicated right-of-way; enlarging the private facilities to account for bypass runoff; or other methods as approved by the City Engineer. [PMC 21.10.190] Civil submittal shall include analysis of mitigation for road and right of way run off. In addition, current plan shows 6-inch pipes in ROW. City Standards 204.3(3-4) calls for public stormwater pipes to be minimum 12 inch diameter and to be demonstrated to be able to accommodate a 25 year storm event with no overtopping.
Miscellaneous Condition Resolved Standard Conditions
Development & Permitting Services
Frontage Improvements are required for this project. During the civil permitting phase submit a design that conforms to frontage code PMC 11.08.135. Work with traffic engineering to determine extents of improvements. [Jamie Carter @ 11/20/2024 12:43 PM]
Miscellaneous Condition Open Standard Conditions
Development & Permitting Services
This type of BMP is now designated by the Department of Ecology as an Underground Injection Well. Review Volume I-2.14 Underground Injection Control Program and Volume I-4 UIC Program. The result will most likely be that the applicant will need to register the “well” through the department of Ecology. This process should be initiated as soon as the project is able.
Miscellaneous Condition Open
Building Division
Provide accessible route from proposed ADA van stall to building entrance and primary function areas. Not fewer than one accessible route connecting accessible parking and accessible passenger loading zones to an accessible entrance. A striped path from loading zone to sidewalk across parking lot is require and assure meets minimum slope requirements. The proposed landscape plan is surrounding parking spaces with no public access to the building. GENERAL BUILDING COMMENTS: Building permits are required. Building plans will need to be complete with all building, mechanical, plumbing, energy code items and accessibility requirements that may apply on the plans. The truss specs will also be required with the truss engineers’ stamps and a layout that matches the submitted plans at the time of submittal. Plans will need to be per the applicable 2021 codes proposed to be adopted March 15, 2024, for all permits. All electrical is permitted by the Washington State Department of L & I. Accessible parking and access to the public way will be required. For all accessible requirements, the City of Puyallup adopted the 2021 IBC / WAC 51-50 and the ICC A117.1-2017 standard. Please reach out to me if I can answer any other questions in relationship to Building code items for this project. No other Building items at this time.

Related Permit & Planning Applications

Reference Number Status Type
PRDE20221598 Closed Demolition
PRCCP20250724 Returned for Correction Civil Construction Permit
PRCA20250966 Returned for Correction Commercial - Addition
PLPRE20220138 File Closed Pre-Application

Documents & Images

Date Uploaded File Type Name
01/09/2024 Form Exhibit 3 - Variance Application
01/09/2024 Receipt Receipt for transaction:2024-000039
01/09/2024 Form Exhibit 9 - Critical Area ID Form
01/09/2024 Form Exhibit 4 - SEPA Checklist
01/17/2024 Email Exhibit 16 - Tacoma Water NOA Response
01/22/2024 Email Exhibit 15 - Squaxin Island Tribe NOA Response
01/22/2024 Exhibit 14 - Affidavit of Notice of Application
03/14/2024 Form Exhibit 2 - Conditional Use Application
07/15/2024 Form Exhibit 8 - Traffic Scoping Worksheet
08/28/2024 Study Exhibit 13 - Preliminary Storm Report
11/20/2024 Drawing Exhibit 7 - Architectural Elevations
04/30/2025 Report Exhibit 10 - Critical Area Report
05/13/2025 Plans Exhibit 5 - Site Plan, Civil Set, Buffer Planting Plan
05/22/2025 Report Exhibit 11 - Stream/Wetland Corridor Buffer Restoration Program
05/29/2025 Plans Exhibit 6 - Zone Transition Buffer Plan
06/10/2025 Exhibit 12 - Critical Area Third Party Review 06102025
06/16/2025 Letter Exhibit 17 - Final Development Review Team (DRT) Letter
07/01/2025 Exhibit 18 - SEPA Determination of Nonsignificance
07/01/2025 Exhibit 1 - Staff Report
07/02/2025 Exhibit 19 - Affidavit of Notice of Hearing
07/23/2025 PLCUV20240004 - HEX Decision 07232025
08/13/2025 Letter Notice of Final Decision


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.