Summary

PRFA20251591
Fire Alarms
Permit(s) Issued
CRP/TP BRADLEY HEIGHTS OWNER LLC
New
1. PROVIDE AND INSTALL NEW 6808 FIRE ALARM CONTROL PANEL FOR OCCUPANT NOTIFICATION.2. PROVIDE AND INSTALL 7 STROBE ONLY NOTIFICATION APPLIANCES.3. PROVIDE AND INSTALL 12 HORN/STROBE NOTIFICATION APPLIANCES.4. PROVIDE AND INSTALL 9 MANUAL PULL STATIONS5. PROVIDE AND INSTALL 6 SMOKE DETECTORS & 1 HEAT DETECTOR.6. PROVIDE AND INSTALL 1 RELAY MODULES FOR BBQ GAS SHUT OFF.7. PROVIDE AND INSTALL 2 DUAL-INPUT MODULES.8. PROVIDE AND INSTALL 5860 REMOTE ANNUNCIATOR. 9. PROVIDE AND INSTALL A HONEYWELL HW-AV-LTE-M CELLULAR COMMUNICATOR.10. ISNPECT AND CERTIFY SYSTEM BRADLEY HEIGHTS CLUBHOUSE
12/04/2025
12/09/2025
07/20/2026

Locations

Reviews

Documents Returned For Corrections

Date Returned Name
12/09/2025 FIRE ALARM PLANS (Stamped)
Review Type Outcome Est. Completion Date Completed
Fire Review Approved 12/30/2025 12/09/2025

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $402.50 $402.50 Paid 12/04/2025
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Not Ready 1/16/2026 01/21/2026
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. Inspections are Monday - Thursday, no friday inspections • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Exterior fire bell required outside fire sprinkler room. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • A pre-test shall be conducted and a printout of the location of the device, point number and descriptor shall be furnished to the inspector at final. Labeling of all devices above and below ceiling required. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • RTU’S and smoke dampeners will be required to be tested during inspection. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • In existing buildings all above ceiling detection is to remain. Do not remove. • Due to unforeseeable construction design, all device locations to be field verified for compliance. Schedule your inspection online through the city of puyallup online permit system after requesting appointment from inspector. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. David Drake 253-864-4171 ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRDE20230753 Closed Demolition
PRFUP20230968 Permit(s) Issued Franchise Utility Permit
PROLP20231232 Closed Oversized Load/House Move Permit
PRDE20231242 Closed Demolition
PRUSR20231244 Canceled Utility Service Repair/PRIVATE PROPERTY ONLY
PRUSR20231267 Closed Utility Service Repair/PRIVATE PROPERTY ONLY
PRCNC20240278 Permit(s) Issued Commercial - New Construction
PRMU20240279 Permit(s) Issued Residential - New Multi-Unit
PRMU20240280 Permit(s) Issued Residential - New Multi-Unit
PRMU20240281 Permit(s) Issued Residential - New Multi-Unit
PRMU20240282 Permit(s) Issued Residential - New Multi-Unit
PRMU20240283 Permit(s) Issued Residential - New Multi-Unit
PRMU20240284 Permit(s) Issued Residential - New Multi-Unit
PRMU20240285 Permit(s) Issued Residential - New Multi-Unit
PRMU20240286 Permit(s) Issued Residential - New Multi-Unit
PRCCP20240845 In Plan Check Civil Construction Permit
PRAMR20241578 Canceled Alternative Methods / Materials Request
PRAMR20250141 Closed Alternative Methods / Materials Request
PRRWF20250214 Permit(s) Issued Retaining Wall
PRRWF20250216 Permit(s) Issued Retaining Wall
PRRWF20250217 Permit(s) Issued Retaining Wall
PRRWF20250233 Permit(s) Issued Retaining Wall
PRRWF20250235 Permit(s) Issued Retaining Wall
PRRWF20250237 Permit(s) Issued Retaining Wall
PRFS20251283 Permit(s) Issued Fire Sprinklers
PRFS20251315 Permit(s) Issued Fire Sprinklers
PRFS20251469 Permit(s) Issued Fire Sprinklers
PRFS20251470 Permit(s) Issued Fire Sprinklers
PRFS20251577 Permit(s) Issued Fire Sprinklers
PRFS20251594 Permit(s) Issued Fire Sprinklers
PRFS20251597 Permit(s) Issued Fire Sprinklers
PRFA20251711 Submittals Incomplete Fire Alarms
PRPO20260015 Returned for Correction Pool/Hot Tub
PRCNC20260042 Submittals Incomplete Commercial - New Construction
PRCNC20260043 Submittals Incomplete Commercial - New Construction
PRCNC20260044 Submittals Incomplete Commercial - New Construction
PRCNC20260045 Submittals Incomplete Commercial - New Construction
PRCNC20260047 Submittals Incomplete Commercial - New Construction
PRCNC20260048 Submittals Incomplete Commercial - New Construction
P-19-0105 Expired Pre-Application
P-21-0098 File Closed Pre-Application
PLDDG20220021 File Closed Downtown Design Review
PLPSP20220049 File Closed Preliminary Site Plan

Documents & Images

Date Uploaded File Type Name
12/04/2025 Receipt Receipt for transaction:2025-002300
12/09/2025 Form (2025-12-04) Bradley Heights Clubhouse - Fire Alarm Permit Application Signed (Flattened)
12/09/2025 Plans FIRE ALARM CUT SHEETS (Flattened)
12/09/2025 Plans FIRE ALARM PLANS (Stamped)
12/09/2025 Permit Permit - Detailed
12/09/2025 Letter Permit Job Card