Summary

PRFA20260628
Fire Alarms
Permit(s) Issued
CRP/TP BRADLEY HEIGHTS OWNER LLC
New
1. PROVIDE AND INSTALL NEW SILENT KNIGHT 6808 FIRE ALARM CONTROL PANEL AND HONEYWELL HPF-PS10 REMOTE POWER SUPPLY FOR OCCUPANT NOTIFICATION. 2. PROVIDE AND INSTALL 29 LOW FREQUENCY SOUNDER NOTIFICATION APPLIANCES. 3. PROVIDE AND INSTALL 5 LOW FREQUENCY SOUNDER STROBE NOTIFICATION APPLIANCES. 4. PROVIDE AND INSTALL 3 STROBE ONLY NOTIFICATION APPLIANCES. 5. PROVIDE AND INSTALL 7 HORN/STROBE NOTIFICATION APPLIANCES & 1 WATERFLOW BELL. 6. PROVIDE AND INSTALL 13 MANUAL PULL STATIONS 7. PROVIDE AND INSTALL 1 SMOKE DETECTOR FOR FACP AND PS10. 8. PROVIDE AND INSTALL 2 DUAL-INPUT MODULES. 9. PROVIDE AND INSTALL 16 HEAT DETCTORS. 10. PROVIDE AND INSTALL A HONEYWELL HW-AV-LTE-M CELLULAR COMMUNICATOR. 11. INSPECT AND CERTIFY SYSTEM. - BRADLEY HEIGHTS APARTMENTS - BLDG B
04/30/2026
06/01/2026
11/28/2026

Locations

Address
206 27TH AVE SE, Unit: B101, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B102, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B103, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B104, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B105, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B106, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B107, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B108, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B109, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B110, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B111, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B112, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B201, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B202, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B203, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B204, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B205, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B206, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B207, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B208, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B209, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B210, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B211, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B212, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B301, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B302, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B303, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B304, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B305, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B306, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B307, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B308, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B309, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B310, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B311, PUYALLUP, WA 98374

Address
206 27TH AVE SE, Unit: B312, PUYALLUP, WA 98374

Property
0419036006

Address
206 27TH AVE SE, PUYALLUP, WA 98374

Reviews

Documents Returned For Corrections

Review Type Outcome Est. Completion Date Completed
Fire Review Approved 05/29/2026 05/29/2026

Fees

Paid Fees Amount Paid Owing Date Paid
Fire Alarm Systems (New) Fee $402.50 $402.50 Paid 04/30/2026
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


Permit(s) will not be issued until outstanding fees have been paid in full. Fee details shown above only include currently payable fees, there might be addtional fees to be paid before issuance.

$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Piv And Tamper Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Cover Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Test Inspection Pending
David Drake ((253) 864-4171)
Fire Alarm Final Inspection Pending
David Drake ((253) 864-4171)

Conditions

Condition Status Category
New Fire Alarm System Conditions Open Standard Conditions
Fire Prevention
• Appointment required for all inspections am/pm is not guaranteed without appointment. Larger systems taking more than 1 hour will require 48-72hr notice prior to scheduling. • Provide plans and permit on site for inspection. • Complete labor and industries inspections prior to requesting city inspection. • Device maps required at the annunciator and fire alarm panel prior to calling in final. The annunciator map will need to be weatherproof. • Total coverage is required, subject to field inspection. Comply with NFPA 72. • Fire alarm system shall be placarded per NFPA 72. The UL certificate shall be posted at time of final inspection. The system will need to be UL certified. • The requirements for Total Coverage on this building are the following. a. 100% complete monitoring of Fire Sprinkler System b. Smoke Detector in Riser Room c. Exterior Fire Bell outside of Riser Room d. Pull Stations at Main Entry’s e. Heat Detectors spaced accordingly throughout attic f. Heat detection in garages g. Shared tenant spaces will require smoke detection h. Horns and strobes are required • Pre-test shall be conducted with a printout for inspector at time of inspection. • Fire sprinkler tamper valves and PIV will be required to be tested at inspection. Fire sprinkler contractor to be onsite. • The city of Puyallup allows one FACP per building. The panel will need to be large enough to handle multiple tenants if applicable. • Due to unforeseeable construction design, all device locations to be field verified for compliance. • The Buildings Fire Alarm system must meet The City of Puyallup’s Municipal Code Total Coverage NPFA 72 and U.L. Certification. The sleeping units are required to be local only with two choices. They can be part of the system but must report as a supervisory (will not dispatch). Or they can be Standard 120V smoke alarms in sleeping/dwelling units. CO detection must comply with IBC and WAC requirements. Installation for local must comply with IBC section 907 requirements. Comply with ADA requirements where required. Schedule your inspection online through the city of puyallup online permit system. This is a request for inspection only. A date and time will be selected by Inspector depending on availability. Email morning of inspection between 7am – 8am for scheduled date and time. Fire Inspections are Monday – Thursday there will be no inspections on Fridays. For larger system please make an appointment prior to scheduling first. David Drake ddrake@puyallupwa.gov

Related Permit & Planning Applications

Reference Number Status Type
PRDE20230753 Closed Demolition
PRFUP20230968 Permit(s) Issued Franchise Utility Permit
PROLP20231232 Closed Oversized Load/House Move Permit
PRDE20231242 Closed Demolition
PRUSR20231244 Canceled Utility Service Repair/PRIVATE PROPERTY ONLY
PRUSR20231267 Closed Utility Service Repair/PRIVATE PROPERTY ONLY
PRCNC20240278 Permit(s) Issued Commercial - New Construction
PRMU20240279 Permit(s) Issued Residential - New Multi-Unit
PRMU20240280 Permit(s) Issued Residential - New Multi-Unit
PRMU20240281 Permit(s) Issued Residential - New Multi-Unit
PRMU20240282 Permit(s) Issued Residential - New Multi-Unit
PRMU20240283 Permit(s) Issued Residential - New Multi-Unit
PRMU20240284 Permit(s) Issued Residential - New Multi-Unit
PRMU20240285 Permit(s) Issued Residential - New Multi-Unit
PRMU20240286 Permit(s) Issued Residential - New Multi-Unit
PRCCP20240845 Permit(s) Issued Civil Construction Permit
PRAMR20241578 Canceled Alternative Methods / Materials Request
PRAMR20250141 Closed Alternative Methods / Materials Request
PRRWF20250214 Permit(s) Issued Retaining Wall
PRRWF20250216 Permit(s) Issued Retaining Wall
PRRWF20250217 Permit(s) Issued Retaining Wall
PRRWF20250233 Permit(s) Issued Retaining Wall
PRRWF20250235 Permit(s) Issued Retaining Wall
PRRWF20250237 Permit(s) Issued Retaining Wall
PRFS20251283 Permit(s) Issued Fire Sprinklers
PRFS20251315 Permit(s) Issued Fire Sprinklers
PRFS20251469 Permit(s) Issued Fire Sprinklers
PRFS20251470 Permit(s) Issued Fire Sprinklers
PRFS20251577 Permit(s) Issued Fire Sprinklers
PRFA20251591 Permit(s) Issued Fire Alarms
PRFS20251594 Permit(s) Issued Fire Sprinklers
PRFS20251595 Permit(s) Issued Fire Sprinklers
PRFS20251597 Permit(s) Issued Fire Sprinklers
PRFA20251711 Permit(s) Issued Fire Alarms
PRPO20260015 Permit(s) Issued Pool/Hot Tub
PRCNC20260042 Permit(s) Issued Commercial - New Construction
PRCNC20260043 Permit(s) Issued Commercial - New Construction
PRCNC20260044 Permit(s) Issued Commercial - New Construction
PRCNC20260045 Permit(s) Issued Commercial - New Construction
PRCNC20260047 Permit(s) Issued Commercial - New Construction
PRCNC20260048 Permit(s) Issued Commercial - New Construction
PRCP20260223 Permit(s) Issued Carport
PRFA20260236 Permit(s) Issued Fire Alarms
PRCP20260239 Permit(s) Issued Carport
PRCP20260242 Permit(s) Issued Carport
PRCP20260244 Permit(s) Issued Carport
PRCP20260245 Permit(s) Issued Carport
PRCP20260246 Permit(s) Issued Carport
PRCP20260247 Permit(s) Issued Carport
PRCP20260250 Permit(s) Issued Carport
PRCP20260251 Permit(s) Issued Carport
PRCP20260252 Permit(s) Issued Carport
PRCP20260253 Permit(s) Issued Carport
PRCP20260254 Permit(s) Issued Carport
PRCP20260257 Permit(s) Issued Carport
PRCP20260264 Permit(s) Issued Carport
PRCP20260265 Permit(s) Issued Carport
PRCP20260266 Permit(s) Issued Carport
PRCP20260267 Permit(s) Issued Carport
PRCP20260269 Permit(s) Issued Carport
PRCP20260270 Permit(s) Issued Carport
PRCP20260271 Permit(s) Issued Carport
PRFA20260294 Permit(s) Issued Fire Alarms
PRRWF20260482 Permit(s) Issued Retaining Wall
PRFA20260484 Permit(s) Issued Fire Alarms
PRFA20260714 Permit(s) Issued Fire Alarms
PRFA20260719 Permit(s) Issued Fire Alarms
PRFA20260720 Permit(s) Issued Fire Alarms
PRSG20260787 Ready for Issuance Sign/Awning
P-19-0105 Expired Pre-Application
P-21-0098 File Closed Pre-Application
PLDDG20220021 File Closed Downtown Design Review
PLPSP20220049 File Closed Preliminary Site Plan

Documents & Images

Date Uploaded File Type Name
04/30/2026 Receipt Receipt for transaction:2026-000763
06/01/2026 Plans (2026-04-14) Bradley Heights Bldg B - FA REV 0 KM Stamp1 (Flattened)
06/01/2026 Plans CUT SHEETS (Stamped)


Should you need assistance, please contact the Permit Center at (253) 864-4165 option 1.