PRCTI20240784
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
Pending
|
|
|
:
:
Interior tenant improvement to construct UPS & Battery Rooms totaling 1,753 sf.
|
PRCTI20240782
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
Pending
|
|
|
:
:
Install seven (7) 2,500 kW standby diesel generators, each generator equipped with an 8,400 gallon above ground fuel storage tank.
|
PRFN20240667
|
Fence
|
New
|
Returned for Correction
|
|
|
:
:
Construct new 8' tall chain link fence around medium voltage switchgear building - CENTERIS VOLTAGE PARK
|
PRCNC20240647
|
Commercial - New Construction
|
New
|
In Plan Check
|
|
|
:
:
Construct 1,144 sf metal building housing electrical switchgear - CENTERIS VOLTAGE PARK
|
PRCTI20240601
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
In Plan Check
|
|
|
:
:
Construct a 2,400 exterior roof shed over exterior electrical switchgear and structural framing for conduit supports - CENTERIS VOLTAGE PARK
|
PRMH20240593
|
Mechanical - COMMERCIAL ONLY
|
Other
|
Permit(s) Issued
|
04/25/2024
|
|
:
:
Phase 2 build-out of existing chilled water plant. Scope includes installation of the following fixtures: (1) Water Cooled Chiller and (1) Chilled water pump, (1) Cooling Tower and Condenser Water Pump, (1) Buffer Tank, and (1) Solid Separator. To include piping connections between new equipment to existing system.
|
PRFO20240573
|
Foundation Only
|
New
|
In Plan Check
|
|
|
:
:
FOUNDATIONS ONLY. Construct new concrete slab on grade and foundation for a 1,144 s.f. pre-manufactured building. Building will be submitted under separate permit - CENTERIS VOLTAGE PARK - SWITCHGEAR BLDG FOUNDATION
|
PRCTI20240560
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
Ready for Issuance
|
|
|
:
:
Cut new floor penetrations for electrical conduit, install structural steel reinforcement around openings, install fire protection assemblies for structural steel.
|
PRCTI20240438
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
Permit(s) Issued
|
04/16/2024
|
|
:
:
Installation of exterior wall penetration assemblies and supplementary metal stud framing and steel headers. BLDG ONLY
|
PRCTI20240333
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
Permit(s) Issued
|
03/20/2024
|
|
:
:
Interior tenant improvements to construct new UPS ROOM of 2,223 s.f. and new BATTERY ROOM of 1,474 s.f. - CENTERIS VOLTAGE PARK
|
PRCTI20240275
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
Permit(s) Issued
|
04/23/2024
|
|
:
:
Installation of foundations and steel supports for exterior chiller piping and electrical conduit, as well as installation of fluid coolers, air cooled chillers, pumps and miscellaneous mechanical equipment - CENTERIS VOLTAGE PARK
|
PRMH20240272
|
Mechanical - COMMERCIAL ONLY
|
Other
|
Permit(s) Issued
|
03/18/2024
|
|
:
:
Phase 1 buildout of the existing chilled water plant. Install (4) new RAUs, Install (16) new Evap/Filter Sections, Install (20) OSA Intake Penthouses on Roof, Install (3) new fan walls w/120 exhaust fans. Provide and install an additional 1,200,000 CFM of building exhaust on the 1st floor to match the total supply of RAU CFM. Sheet metal connections between new equipment to existing system. - CENTERIS VOLTAGE PARK
|
PRFO20240187
|
Foundation Only
|
New
|
Permit(s) Issued
|
02/20/2024
|
|
:
:
Installation of concrete pad foundations for standby generators and exterior electrical equipment. - CENTERIS VOLTAGE PARK
|
PRFO20240140
|
Foundation Only
|
New
|
Permit(s) Issued
|
02/20/2024
|
|
:
:
Install concrete slab on grade pads and foundations for exterior mechanical equipment, totaling 2,226 s.f. of concrete slab. CHILLER AND COOLER FOUNDATIONS - CENTERIS VOLTAGE PARK
|
PRFO20231761
|
Foundation Only
|
New
|
Permit(s) Issued
|
02/07/2024
|
|
:
:
Installation of two exterior concrete pads for standby diesel generators - CENTERIS VOLTAGE PARK
|
PRCTI20221271
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
Canceled
|
|
|
:
:
NEW INTERIOR PARTITIONS AND DOORS TO SURROUND TWO EXISTING CHILLER MACHINES. NEW ACT CEILING GRID, TILE AND LIGHTING IN NEW ROOM.
|
B-18-0408
|
Commercial - Tenant Improvement/Remodel
|
Alteration/Remodel
|
Expired
|
09/24/2018
|
|
:
:
TI - CENTERIS DATA CENTER SEE B-18-0311 FOR MECHANICAL
|
B-18-0311
|
Mechanical - COMMERCIAL ONLY
|
Other
|
Expired
|
08/06/2018
|
|
:
:
(2) 575 ton variable speed York centrifugal chillers, (2) cooling otwers with SS sump, sump heater service ladder and guardrails. (2) base mounted end suction centrifugal pumps with VFD for chillers (2) base mounted end suction centrifugal pumps with VFD for cooling towers (1) Alfa Laval flat plate HX for cooling tower with VFD to accommodate economizer operation.
|
B-15-0891
|
Commercial - New Construction
|
Other
|
Closed
|
09/24/2015
|
|
:
:
TI ~ 204 SQ FT FACILITIES OFFICE (INSIDE EXISTING OFFICE AREA)
~ SOUTH HILL DATA CENTER
**BLDG ONLY**
|
B-15-0629
|
UNKOWN LEGACY PERMIT TYPE
|
Other
|
Closed
|
06/24/2015
|
|
:
:
STRUCTURAL STEEL FOR CABLE BUSWAY; EXT. PENETRATIONS~SOUTH HILL DATA CENTER
|
B-15-0075
|
Commercial - New Construction
|
Other
|
Canceled
|
|
|
:
:
CONCRETE FOR (3) FUEL TANKS ~SOUTH HILL DATA CENTER
|
B-15-0076
|
UNKOWN LEGACY PERMIT TYPE
|
Other
|
Closed
|
03/04/2015
|
|
:
:
CONCRETE FOR (3) FUEL TANKS ~SOUTH HILL DATA CENTER
|
B-15-0048
|
Commercial - New Construction
|
Other
|
Expired
|
02/13/2015
|
|
:
:
CONCRETE GENERATOR PADS ~SOUTH HILL DATA CENTER
*E-15-0064*
|
E-13-0327
|
UNKOWN LEGACY PERMIT TYPE
|
Other
|
Closed
|
09/10/2013
|
|
:
:
JOB # METRO-E JT #94638
Extended until February 15, 2014. LL
|
B-09-0278
|
Commercial - New Construction
|
Other
|
Closed
|
06/04/2009
|
|
:
:
T.I. COMM - DATA CENTER - BUILDING D - SOUTH HILL BUSINESS & TECHNOLOGY CENTER
|